Instruction Manual PSE2xxDN
10
Name
Attr.
No.
Function
Range of
value
Back
up
Delivery
State
R/W
maximum
start-up
torque
24
value in cNm
see table
16 bit
yes
see
table
R/W
time period
for start-up
torque
25
value in msec
10...1000
16 bit
yes
200
R/W
rpm limit for
aborting run
26
value in % of the target rpm
10...90
16 bit
yes
30
R/W
time elapsed
until speed
falls below
rpm limit for
aborting run
27
value in msec
50...500
16 bit
yes
200
R/W
length of loop 31
minimum number of increments which the
drive moves in a pre-defined direction
when approaching a target position
value in increments (value = 0
no loop)
0.025…1
rotations
(10…400
at del.
state) or
0
32 bit
yes
250
R/W
maximum
rpm, counter-
clockwise
32
value in rpm
see table
16 bit
yes
see
table
R/W
maximum
rpm,
clockwise
33
value in rpm
see table
16 bit
yes
see
table
R/W
step width for
single step
34
number of increments when activating a
jog run bit for a short-time
1...100
16 bit
yes
1
R/W
idle period for
manual run
35
Span of time which a jog run bit must be
activated in order to begin a manual run
value in steps of 5 msec
20...2000
16 bit
yes
200
R/W