background image

97095C (Rev. E - 10/99)

PAGE 1

RC8*C  RC12*C  AND 14762 & 14700 CUP DISPENSER

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

Halsey Taylor Owners Manual

Fully-Recessed Barrier-Free Water Cooler

INSTALLER

To assure you install these models easily and correctly,

PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE

INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMB-

ING, ELECTRICAL, AND OTHER APPLICABLE CODES. After

installation, leave these instructions with the Water Cooler for future reference.

RC

RC W/CUP DISPENSER

FIG. 1

FIG. 2

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER

LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY

FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING

AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE

WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN

FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE

FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

1/4" O.D. TUBE WATER INLET TO COOLER

SERVICE STOP

(NOT FURNISHED)

NOTE:  WATER FLOW DIRECTION

BUILDING WATER INLET

3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY

Содержание RC8*C Series

Страница 1: ... FIG 2 IMPORTANT INSTALLER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TOWATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOID...

Страница 2: ...r Models Install rough plumbing to cup dispenser See Fig 13 for location of waste water outlet 5 Cut plastic ties holding chiller shelf support rods to framework 6 Install wall frame assembly in wall opening with front edge of frame flush with finished wall face Secure frame through holes in top and sides to wall support members with 5 16 diameter fasteners bolts or lag screws as required by wall ...

Страница 3: ...RNING Adequate space must be maintained behind the refrigeration unit for air circulation 8 Water supply connections See Fig 7 8 A RC8A Models Connect service stop to tube marked Water Inlet on remote chiller Make connection from chiller Cold Water Outlet tube to regulator valve assembly using the provided elbow and strainer B RC12A Models Connect service stop to precooler tailpiece assembly inlet...

Страница 4: ...Y CONNECTIONS RC12A 12AGF MODELS TO BUBBLER CHILLER OUTLET 27 19 24 25 FIG 7 FIG 7A FIG 8 FIG 8A TO BUBBLER CHILLER INLET CHILLER OUTLET 27 19 24 25 TO BUBBLER CHILLER INLET CHILLER OUTLET 27 19 24 25 TO GLASSFILLER TO GLASSFILLER TO BUBBLER CHILLER INLET CHILLER OUTLET 27 19 24 25 CHILLER INLET Item 3 Page 7 Item 3 Page 7 ...

Страница 5: ...ignment with previously installed drinking fountain Be sure to check for proper operation of access door before securing unit in place Securing can be done through slots provided using screws or bolts as required by wall construction 3 Replace waste bin FIG 9 FIG 10 PLUMBING ROUGH IN CUP DISPENSER WITH GLASS FILLER NOTE If wall opening height has been adjusted to meet local codes see Step No 1 of ...

Страница 6: ...od alignment with fountain Open and close door to ensure proper operation CAUTION Do not suspend cup dispenser via the mounting slots be sure to shim along bottom edge to bear the weight of the cup dispenser 6 Secure cup dispenser in place Use lag screws or bolts as required by wall construction 7 Install glass filler supply tube assembly Figure 11 Put glass filler fitting through hole provided in...

Страница 7: ...p Nut Hex Washer Fibre Gasket Drain Gasket Slip Nut Nut Hex Strainer Plate Tailpipe 1 1 4 x 4 Nut Slip 1 1 2 Plug Drain 1 1 2 FIG 12 FIG 13 10 BASIN 9 11 13 7 8 12 1 3 2 4 5 6 See Fig 12 IMPORTANT Fountain and glassfiller are rated for a supply pressure of 90 PSI minimum If supply pressure exceeds this a pressure reducing regulator should be installed on the supply line Minimum supply pressure 15 ...

Страница 8: ...me Cover Nut Aztec Gold Strainer Screw 8 x 3 4 Type AB Elbow Drain Nut Slip Joint 1 1 4 Gasket Drain Tube Cu 3 8 x 4 75 Tube Cu Regulator In Tube Assy Bubbler 8880 Fitting Elbow TROUBLE SHOOTING AND MAINTENANCE CAUTION Cleaning of Aztec Gold Models requires special care Outer surfaces must be cleaned with a mild detergent or mixture of vinegar and water only rinsed and wiped dry Abrasive and acidi...

Отзывы: