background image

1000002449  (Rev. E - 04/18)

OVLEBPWSI_NF     OVLEBPWSI_WF

Page 3

Figure 3 - HTHBWF-OVLEBP-I Tube Routing

  

     REQUIRED TOOLS AND MATERIALS

  These tables show special tools and/or additional materials

  (not provided) which are necessary to complete installation

  of these units:

12

28

Figure 2 - HTHB-OVLEBP-I Tube Routing

TO BUBBLER

16

FILTER

ASSEMBLY

12

WATER

INLET

Special Tools

Item

Description

Quantity

NONE

Additional Materials Not Included

Item

Description

Quantity

Unplated copper inlet pipe
Service Stop/Shut-off Valve
90° 1-1/4” Drain Line
1-1/4” Tee Drain Line

1
2
3
4

1
1
1
1

WATER

INLET

28

27

TO BOTTLE

FILLER

TO BUBBLER

25

28

14

TO BOTTLE

FILLER

 1.

 Make water supply connections

 (Fig 13). Install a shut-off 

  valve and union connection to building water supply (valve

  and union not provided). Turn on water supply and flush

  the line thoroughly.

 Caution: 

DO NOT SOLDER tubes inserted into the

 

strainer or filter head as damage to the o-rings may result.

  2. 

Install mounting frame

 (instructions supplied with mounting 

 frame.

  3. 

(For HTHB-OVLEBP-I)

 Install 3/8” tee, poly tubing and strainer 

 

per (Fig 2).

  4. 

(For HTHBWF-OVLEBP-I)

 

Access

 to the interior of the unit is  

 

necessary for filter mounting and changing. Filter mounting loca- 

 

tion is open to installer’s discretion. Recommended location to be  

 

within 18” of service stop (not supplied).

 

Install the filter head

 to the bracket then install filter bracket to

 

appropriate surface near fountain. Next install a 1/4” elbow to 

 

filter head outlet.  

  4a. 

Install 

the supplied 4” poly tubing and armaflex to the previously  

       installed elbow. Connect supplied 1/4” x 1/4” x 3/8” tee to the 4” 

       poly tubing. With the back panel standing close to the frame, 

       connect 3/8” poly tube coming from the bottle filler to the tee

       per (Fig. 3).

 

    

  5. 

Hang main panel

 on mounting frame hanger. Make sure the

 

power cord, reset switch wire & poly tube do not get pinched 

 

between the panel & mounting frame. Ensure the panel engages

 

at the top. Align fountain holes with mounting frame holes.

 

  

  6. 

Remove protective coating

 from main panel.

  7. 

Install

 reset switch for bottle filler (Fig 5). Snap the switch into 

      position after locating wires through slot. Wrap up the excess

      cord.

12

Содержание OVL

Страница 1: ...ack in the plumbing circuit which results in an electrolysis effect occurring in the fountain This may result in water which has a metallic taste to it or has a noticeable increase in the metallic con...

Страница 2: ...8 203mm MINIMUM 12 305mm RECOMMENDED FOR DRAIN CONNECTION AND ACCESS TO BOTTLE FILLER ELECTRICALS 1 1 2 38mm 16 1 2 419mm 21 1 2 546mm ACTIVATION SENSOR 1 1 2 IPS WASTE LINE 3 8 IPS SUPPLY 1 1 4 32mm...

Страница 3: ...ions supplied with mounting frame 3 For HTHB OVLEBP I Install 3 8 tee poly tubing and strainer per Fig 2 4 For HTHBWF OVLEBP I Access to the interior of the unit is necessary for filter mounting and c...

Страница 4: ...in front of sensor area and verify water dispenses Note the first initial dispenses might have air in the line which may cause a sputter This will be eliminated once all air is purged from the line A...

Страница 5: ...ter Brkt includes Fltr Head Mtg Bkt John Guest Fittings Screws 1 2 3 55898C 98926C 51469C DESCRIPTION PART NO WATERSENTRY PLUS FILTER PARTS LIST See Fig 11 2 3 Figure 8 Push Bar Mechanism Figure 9 Reg...

Страница 6: ...SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count Continued from below 3 When display shows UNIT TYPE push program butto...

Страница 7: ...LOCATION MOUNTING FRAME Figure 13 Water Supply Connections NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 4 O D TUBE WATER INLET TO COOLER 3 8 O D UNPLATED COP PER TUBE CO...

Страница 8: ...28 29 30 31 32 51546C 27006C 27000C 27002C 26988C 55840C 55836C 55839C 45683C 0000001153 1000002143 56092C 1000001940 55996C 161570808550 000001772 111008343890 112627543890 98732C 75560C 27008C 7085...

Отзывы: