1000002449 (Rev. E - 04/18)
OVLEBPWSI_NF OVLEBPWSI_WF
Page 3
Figure 3 - HTHBWF-OVLEBP-I Tube Routing
REQUIRED TOOLS AND MATERIALS
These tables show special tools and/or additional materials
(not provided) which are necessary to complete installation
of these units:
12
28
Figure 2 - HTHB-OVLEBP-I Tube Routing
TO BUBBLER
16
FILTER
ASSEMBLY
12
WATER
INLET
Special Tools
Item
Description
Quantity
NONE
Additional Materials Not Included
Item
Description
Quantity
Unplated copper inlet pipe
Service Stop/Shut-off Valve
90° 1-1/4” Drain Line
1-1/4” Tee Drain Line
1
2
3
4
1
1
1
1
WATER
INLET
28
27
TO BOTTLE
FILLER
TO BUBBLER
25
28
14
TO BOTTLE
FILLER
1.
Make water supply connections
(Fig 13). Install a shut-off
valve and union connection to building water supply (valve
and union not provided). Turn on water supply and flush
the line thoroughly.
Caution:
DO NOT SOLDER tubes inserted into the
strainer or filter head as damage to the o-rings may result.
2.
Install mounting frame
(instructions supplied with mounting
frame.
3.
(For HTHB-OVLEBP-I)
Install 3/8” tee, poly tubing and strainer
per (Fig 2).
4.
(For HTHBWF-OVLEBP-I)
Access
to the interior of the unit is
necessary for filter mounting and changing. Filter mounting loca-
tion is open to installer’s discretion. Recommended location to be
within 18” of service stop (not supplied).
Install the filter head
to the bracket then install filter bracket to
appropriate surface near fountain. Next install a 1/4” elbow to
filter head outlet.
4a.
Install
the supplied 4” poly tubing and armaflex to the previously
installed elbow. Connect supplied 1/4” x 1/4” x 3/8” tee to the 4”
poly tubing. With the back panel standing close to the frame,
connect 3/8” poly tube coming from the bottle filler to the tee
per (Fig. 3).
5.
Hang main panel
on mounting frame hanger. Make sure the
power cord, reset switch wire & poly tube do not get pinched
between the panel & mounting frame. Ensure the panel engages
at the top. Align fountain holes with mounting frame holes.
6.
Remove protective coating
from main panel.
7.
Install
reset switch for bottle filler (Fig 5). Snap the switch into
position after locating wires through slot. Wrap up the excess
cord.
12