VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will   

  need to be shut down and restarted. The chiller (if present) does

  not need to be shut down and restarted.

2) Shut down the unit by unplugging the power cord from the wall     

  outlet or switching off the circuit breaker to the unit. 

3) Restart the unit by plugging the power cord back into the wall 

    outlet or by switching on the circuit breaker to the unit.

4) Upon start up, the bottle count display will show the software 

    designation of BF11 or BF12.

ACCESSING THE PROGRAMMING BUTTON

1) To access the program button, remove the bottom cover on 

  fountain arm (Fig 5) by removing the bottom cover screws. Reset  

  button  is located on mounting bracket.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds until the

  display changes then release. The display will change and scroll

  through two messages:

       “RST FLTR” – Reset Filter Monitor

       “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll

  through the two messages above for three cycles and then default 

  back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button  

  again. The display will change to show “FLTR =”. Depress the

  button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual filter  

  monitor has been reset.

 SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE

1) Depress the program button for approximately 2 seconds until the 

  display changes then release. The display will change and scroll 

  through two messages:

       “RST FLTR” – Reset Filter Status LED

       “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

  through the two messages above for three cycles and then default 

  back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button  

  again. The display will change to show

      “RNG SET” -  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      “FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

3) When display shows “RNG SET” push program button once the 

  display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to scroll  

  through value of 1 – 10. Select the desired range setting, "1" being 

  closest to sensor and "10" being farthest away.

5) Once range is selected allow approximately 4 seconds to pass and

  then the display will go back to bottle counter and be in run mode.

6) Test bottle filler by placing bottle or hand in front of sensor to make  

  sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

  display changes then release. The display will change and scroll  

  through two messages:

       “RST FLTR” – Reset Filter Status LED

       “SETTINGS” – System Settings Sub Menu

  If the program button is not pushed again the display will scroll 

  through the two messages above for three cycles and then default 

  back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button  

  again.  

    The display will change to show

       “RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

Continued from below:

3)  When display shows “UNIT TYPE” push program button once the

    display will show current value.  Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is    selected the display 

    will show the new value.  (Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this setting the flow rate is 

    estimated at 1.0 gallon per minute.

     “NON-RFRG“ - stands for nonrefrigerated product. In this setting the  

    flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ and 

    “NON-RFRG“ simulate   1 bottle equal to 20 oz.

5)  Allow approximately 4 seconds to pass and the display will return to    

    bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll

    through two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through  

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “RST BCNT” push program button once the

    display will show current value, e.g. “0033183”.

4) Once display shows current value push the program button once more 

    to reset back to 0. The display will show BTLCT = 0 for approximately 2 

    seconds and then return to run mode showing 00000000 bottles. 

 

NOTE: Once the bottle count is reset to zero there is no way to 

  return to the previous bottle count.

5)  Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor for approximately 

  9 seconds to see bottle counter count 00000001, 

     (This is based on filling a 20 oz. bottle).

     NON-RFRG units: Place bottle or hand in front of sensor for 

  approximately 6 seconds to see bottle counter count 00000001,

     (This is based on filling a 20 oz bottle).

    

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll through 

    two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through 

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET“-  Range set for IR sensor.

      “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      

 “FLT SIZE” - Select filter capacity

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “FLT SIZE” push program button once. The display 

     will show current value. Can be 3000GAL or 6000GAL.

4)  Push program button again to display the desired “FLT SIZE”. 

5)  Allow approximately 4 seconds to pass and the display will return to 

     bottle counter and be in run mode.

BF11 - BF12 PROGRAM

SETTING THE CONTROL BOARD

Содержание OVL

Страница 1: ...ack in the plumbing circuit which results in an electrolysis effect occurring in the fountain This may result in water which has a metallic taste to it or has a noticeable increase in the metallic con...

Страница 2: ...8 203mm MINIMUM 12 305mm RECOMMENDED FOR DRAIN CONNECTION AND ACCESS TO BOTTLE FILLER ELECTRICALS 1 1 2 38mm 16 1 2 419mm 21 1 2 546mm ACTIVATION SENSOR 1 1 2 IPS WASTE LINE 3 8 IPS SUPPLY 1 1 4 32mm...

Страница 3: ...ions supplied with mounting frame 3 For HTHB OVLEBP I Install 3 8 tee poly tubing and strainer per Fig 2 4 For HTHBWF OVLEBP I Access to the interior of the unit is necessary for filter mounting and c...

Страница 4: ...in front of sensor area and verify water dispenses Note the first initial dispenses might have air in the line which may cause a sputter This will be eliminated once all air is purged from the line A...

Страница 5: ...ter Brkt includes Fltr Head Mtg Bkt John Guest Fittings Screws 1 2 3 55898C 98926C 51469C DESCRIPTION PART NO WATERSENTRY PLUS FILTER PARTS LIST See Fig 11 2 3 Figure 8 Push Bar Mechanism Figure 9 Reg...

Страница 6: ...SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count Continued from below 3 When display shows UNIT TYPE push program butto...

Страница 7: ...LOCATION MOUNTING FRAME Figure 13 Water Supply Connections NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 4 O D TUBE WATER INLET TO COOLER 3 8 O D UNPLATED COP PER TUBE CO...

Страница 8: ...28 29 30 31 32 51546C 27006C 27000C 27002C 26988C 55840C 55836C 55839C 45683C 0000001153 1000002143 56092C 1000001940 55996C 161570808550 000001772 111008343890 112627543890 98732C 75560C 27008C 7085...

Отзывы: