 PERMA PURE LLC 

Model 3300 User’s Manual 

Doc. #532: Revision: 000 
Page 6 of 14 

 

 

Important Safety Warnings 

 

Please be sure to review the following basic safety procedures. These procedures 

represent the MINIMUM requirements to operate the equipment safely. It is the ultimate 
responsibility of the operator to ensure proper safety practices are utilized at the point 
of operation. 

 

 

NEVER 

attempt to operate this equipment in an explosive or otherwise hazardous area.

 

 

NEVER

 exceed any specified rating for the equipment. Voltage, temperature and pressure 

ratings must be closely observed and not exceeded. Voltage rating of the equipment 

MUST

 

match the rating on the data label. Please make sure that it matches before powering up the 

equipment.

 

 

This equipment is 

NOT

 designed to be used in an explosive environment.

 

 

This equipment is 

NOT

 designed to operate in a wet environment.

 

 

Sample gas is potentially dangerous

. A leak test is recommended at initial startup and as 

often as necessary to maintain a safe working environment around the equipment. The gas 
stream exhaust must exit away from all personnel to prevent dangerous exposure. 

 

NEVER operate the equipment with any part of the enclosure unsecured

. All operated 

doors and covers must be in place and secured prior to operation. Electrical current may be 

present behind covers or doors, even if tools are not necessary to access these components. 

 

NEVER

 attempt service on this equipment without first disconnecting all energy sources. 

Repair of this equipment should only be done by properly trained personnel that are familiar 

with the potential risks involved with servicing of the equipment. 

 

NEVER

 replace fuses with types other then the sample specification of type and current. Do 

not bypass this or any other safety device. 

 

NEVER

 operate this equipment if it is visibly damaged or the possibility exists that it may have 

been damaged. 

 

The use of components that have not been purchased through an authorized Perma Pure 

dealer or directly from Perma Pure may compromise the safety of the operator. Additionally, 
use of non-authorized components may change the operating characteristics of this equipment. 
Any changes to the equipment, that modify its operation in any way, are dangerous, and are 

strictly prohibited. 

 

Read the entire operating manual before attempting to set up or operate the equipment. 

 

Please heed all warning labels that are on the equipment. They are there to remind you of 
possible hazardous conditions. 

 

Verify the integrity of any mechanical and/or electrical connections that are made to the unit. 

ƒ

 

Verify that the unit is connected to the proper rated power for the system 

ƒ

 

Verify that the unit is plumbed properly to operate effectively 

Содержание PERMA PURE 3300

Страница 1: ...C 732 244 0010 800 337 3762 fax 732 244 8140 www permapure com info permapure com PERMA PURE LLC 8 Executive Drive P O Box 2105 Toms River NJ 08754 Baldwin Series Model 3300 3300P Flow Control Drawer...

Страница 2: ...ard Option 7 Local Mode Operation 8 Computer Control Mode Operation 8 Computer Control Terminals Summary 9 Computer Sense Terminals Summary 9 COMPUTER CONTROL TRUTH TABLE 10 Pressure Sensor Model 3300...

Страница 3: ...ly a carrier must be notified within 24 hours of the delivery to make a hidden damage claim Items in the carton include 1 Model 3300 Flow Control Drawer 1 User s Manual If any of the above parts are m...

Страница 4: ...to the stack filter head and through the entire sample system to the calibration gas introduced directly to the continuous gas analyzer common sample manifold This check indicates problems such as sy...

Страница 5: ...ack Specify 12 VDC line voltage or dry contact Electrical requirements 90 240 VAC 50 60 Hz 100 watts Connections refer to Appendix A3 for back panel drawing 1 All Sample Gas Connections are via 1 4 st...

Страница 6: ...ed prior to operation Electrical current may be present behind covers or doors even if tools are not necessary to access these components NEVER attempt service on this equipment without first disconne...

Страница 7: ...gas solenoid valve and either the system solenoid valve or direct solenoid valve have been selected In Local mode the calibration gas solenoid valves are cascaded that is if there are more than one 1...

Страница 8: ...calibration toggle the Direct System switch to the left Then toggle any of the Calibration Gas switches to the right This will allow the selected calibration gas to flow to the analyzer suite directl...

Страница 9: ...ong with the computer control mode of operation a computer verification method is also incorporated into the system A 40 pin vertical terminal block on the back panel allows the computer to verify the...

Страница 10: ...n 7 Direct Calibration 8 Blowback D Disabled Pressure Sensor Model 3300P The pressure sensor option provides Vacuum pressure sensor 0 15 psig Sample pressure sensor 0 30 psig Calibration gas pressure...

Страница 11: ...tle Cal gas solenoid not operating Flow drawer regulator set 10psig Cal gas Flowmeter closed Block bleed solenoid constantly vents System cal gas solenoid valve defective Direct cal gas solenoid valve...

Страница 12: ...001 2 way solenoid valve 12 VDC 2VSB 002 3 way solenoid valve 12 VDC 2FTS 021 Cal Gas connector 3DCB 006 Circuit board switch board FCD 4D 3300P 2FTS 021 Cal Gas connector 3DCB 006 Circuit board swit...

Страница 13: ...PYRIGHT 2008 ALL RIGHTS RESERVED Original Instructions PERMA PURE LLC Model 3300 User s Manual Doc 532 Revision 000 Page 13 of 14 Appendix A Flow Control Drawer Drawings A1 Panel drawing A2 Flow schem...

Страница 14: ...e suitable or desirable for any particular use or application 2 Buyer takes sole responsibility for the use and applications to which the product is put and Buyer shall conduct all testing and analysi...

Страница 15: ...Form C contact 1 Amp 2 Outputs are terminated on the Flow Control Drawer back panel on the Pressure Transducer Terminal Strip Connections N O Common N C Vacuum Pin 11 Pin 12 Pin 13 Sample Pin 14 Pin 1...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Отзывы: