5. Compressed Air Requirements  

 

 

5.1 The OEM/apparatus builder shall supply dry compressed air with a minimum of 75 psi, a maxi-mum of 

150 psi. (Typically, from the vehicle air brake system which is typically capable of the 90 psi to 150 psi at 

approximately 13 cfm at 1250 rpm.) The pump kit or module provides a loose coil of hose to connect the 

OEM/apparatus builder supplied air. See Figure 53. The air supply should include a protection valve as 

required by DOT standards. 

 

 

Connect to Truck Air Tag 

 

 

6.  Plumbing Connections 

 

 

6.1 Water Column tubing.  
A Coil of 3/4-in tubing (loose or pre-connected at SAM end) SAM end connects to fitting on the SAM Drain 

Manifold Assy. Plumb to top of onboard water tank fill tower (above the overflow level–in atmosphere)  
Labeled as “PLUMB TO TOP OF TANK” 
Note: At the onboard water tank access/fill tower, route the 3/4-in flex line to prevent (to maximum extent 

possible) incidental items (bags of oil dry, spare supply containers, etc.) from being placed on the tubing and 

damaging/breaking it. 
 

 

6.2 Tank Valves 

Connect tank-to-pump and tank fill valves to the apparatus on board tank. 

 

 

6.3 Connect Drains as labeled. No connection needed on those labeled “to atmosphere”. 

 

 

 

 

 

 

 

 

Содержание SAM

Страница 1: ...CES THIS GUIDE IS INTENDED FOR QUICK REFERENCE ONLY DO NOT USE IT TO REPLACE REQUIRED TRAINING STANDARD OPERATING GUIDELINES REQUIRED BY THE AUTHORITY HAVING JURISDIC TION THE OPERATION INSTALLATION M...

Страница 2: ...N LIGHT ON THE IN CAB CONTROL PANEL AND THROTTLE READY GREEN LED ON THE TWISTER INDICATORS AND THE PUMP CONTROLLER ARE ON BEFORE AT TEMPTING TO OPERATE THE PUMP FOLLOW ALL SOG STANDARD OPERATING GUIDE...

Страница 3: ...3 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210 2 Typical Panel layout...

Страница 4: ...4 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Страница 5: ...P primer system respectively OTHER ELECTRICAL COMPONENTS MUST NOT BE SUPPLIED FROM THE SAM SYSTEM SUPPLY DO NOT CONNECT THE PRIMER AND HALE SAM TO THE SAME POWER WIRE When an optional SmartFOAM system...

Страница 6: ...uts Located by the Blue engine can bus connection on the left frame rail 4 4 Tank level transducer s Install tank level transducers as per ITL40 manual Calibrate ITL40 s per ITL40 manual or from 800 s...

Страница 7: ...dards Connect to Truck Air Tag 6 Plumbing Connections 6 1 Water Column tubing A Coil of 3 4 in tubing loose or pre connected at SAM end SAM end connects to fitting on the SAM Drain Manifold Assy Plumb...

Страница 8: ...y constant 12Vdc power and ground to provided power supply and connect to docking station This should be always powered and protected on a 10amp circuit 8 WIFI router antenna if equipped 8 1 Mount abo...

Страница 9: ...Verify SAM system water column sensor hose 10 feet of 3 4 in flex tubing provided is connected to vehicle Refer to Technical Manual FSG MNL 00211 Verify SAM system interlock wiring is connected to veh...

Страница 10: ...10 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210 10 SAM panel components...

Страница 11: ...11 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Страница 12: ...12 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Страница 13: ...13 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Страница 14: ...14 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Отзывы: