FOR MORE INFO REFERENCE OIM MANUAL P/N FSG–MNL–00210 

 

 

 

1.

 

SAFETY 

Firefighting is an inherently risky activity. Knowledge and training may manage that risk. This document is 

not a training manual and does not provide all detailed operation. This guide serves as a quick reference for 

SAM operation. AHJ (Authority Having Jurisdiction) shall provide training and guidelines for system operation. 
1.1

 

DANGERS, WARNINGS, CAUTIONS, and NOTICES 

DANGERS, WARNINGS, CAUTIONS, and NOTICES consist of two parts: a heading (that identifies possible re- 

sult if disregarded) and a statement of the hazard (that provides the minimum precautions). The following 

warnings and cautions are used throughout the Hale SAM manuals. 

 

INDICATES A HAZARDOUS SITUATION, WHICH IF NOT AVOIDED WILL RESULT IN SERIOUS INJURY 

OR DEATH. 

 

INDICATES A HAZARDOUS SITUATION, WHICH IF NOT AVOIDED COULD RESULT IN SERIOUS INJURY 

OR DEATH. 

INDICATES A POTENTIALLY HAZARDOUS SITUATION, WHICH IF NOT AVOIDED MAY RESULT IN MI- 

NOR OR MODERATE INJURY. 

 

ADDRESSES PRACTICES NOT RELATED TO PERSONAL INJURY. 

1.2

 

SAM General WARNING And NOTICES 

 

ENSURE THE OK TO PUMP (GREEN LIGHT ON THE IN-CAB CONTROL PANEL) AND THROTTLE READY 

(GREEN LED ON THE TWISTER) INDICATORS AND THE PUMP CONTROLLER ARE ON BEFORE AT- 

TEMPTING TO OPERATE THE PUMP. FOLLOW ALL SOG (STANDARD OPERATING GUIDELINES) FOR 

PARKING BRAKE, PUMP ENGAGEMENT, AND WHEEL CHOCKS. 

 

SAM PROVIDES AUTOMATED CONTROL OF EACH INDIVIDUAL DISCHARGE LINES PRESSURE. 

WHILE FLOWING, THE VALVES GATE TO MAINTAIN THE SET PRESSURE. ADDITIONAL FEATURES 

ASSIST THE OPERATOR WITH THE TRANSITION FROM TANK TO HYDRANT (OR DRAFTING). LOW 

INTAKE MONITORING FOR A HYDRANT AND LOW FLOW DETECTION FOR DISCHARGES (CAN HELP 

INFORM THE OPERATOR IF A NOZZLE IS CLOSED OR A HOSE LINE IS SEVERELY KINKED). AD- 

VANCED FEATURES CALCULATE PUMP FLOW RATES ABOVE 600 GPM AND PROVIDE ADVANCED 

MAINTENANCE REMINDERS TO REDUCE LIFE CYCLE COSTS. 

WHILE SAM CAN REDUCE PUMP OPERATOR WORKLOAD, IT DOES NOT TAKE THE PLACE OF THE 

PUMP OPERATOR. THE PUMP OPERATOR STILL NEEDS TO CALCULATE THE REQUIRED LINE PRES- 

SURE TO SUPPORT THE HOSE LAY AND NOZZLE IN USE. SAM WILL MAINTAIN THE SET PRESSURE 

IN AUTO MODE. 

 

AHJ MUST INSURE PROPER TRAINING IS IN PLACE FOR ALL OPERATORS. THIS QUICK START GUIDE 

DOES NOT REPLACE OR SUPERSEDE THE OPERATION INSTALLATION MAINTENANCE MANUAL OR 

PROPER TRAINING. 

 

 

ONLY TOUCH THE SCREEN IN ONE PLACE AT A TIME. THE TOUCHSCREENS DO NOT SUPPORT 

MULTI–TOUCH. 
 

Содержание SAM

Страница 1: ...CES THIS GUIDE IS INTENDED FOR QUICK REFERENCE ONLY DO NOT USE IT TO REPLACE REQUIRED TRAINING STANDARD OPERATING GUIDELINES REQUIRED BY THE AUTHORITY HAVING JURISDIC TION THE OPERATION INSTALLATION M...

Страница 2: ...N LIGHT ON THE IN CAB CONTROL PANEL AND THROTTLE READY GREEN LED ON THE TWISTER INDICATORS AND THE PUMP CONTROLLER ARE ON BEFORE AT TEMPTING TO OPERATE THE PUMP FOLLOW ALL SOG STANDARD OPERATING GUIDE...

Страница 3: ...3 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210 2 Typical Panel layout...

Страница 4: ...4 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Страница 5: ...P primer system respectively OTHER ELECTRICAL COMPONENTS MUST NOT BE SUPPLIED FROM THE SAM SYSTEM SUPPLY DO NOT CONNECT THE PRIMER AND HALE SAM TO THE SAME POWER WIRE When an optional SmartFOAM system...

Страница 6: ...uts Located by the Blue engine can bus connection on the left frame rail 4 4 Tank level transducer s Install tank level transducers as per ITL40 manual Calibrate ITL40 s per ITL40 manual or from 800 s...

Страница 7: ...dards Connect to Truck Air Tag 6 Plumbing Connections 6 1 Water Column tubing A Coil of 3 4 in tubing loose or pre connected at SAM end SAM end connects to fitting on the SAM Drain Manifold Assy Plumb...

Страница 8: ...y constant 12Vdc power and ground to provided power supply and connect to docking station This should be always powered and protected on a 10amp circuit 8 WIFI router antenna if equipped 8 1 Mount abo...

Страница 9: ...Verify SAM system water column sensor hose 10 feet of 3 4 in flex tubing provided is connected to vehicle Refer to Technical Manual FSG MNL 00211 Verify SAM system interlock wiring is connected to veh...

Страница 10: ...10 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210 10 SAM panel components...

Страница 11: ...11 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Страница 12: ...12 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Страница 13: ...13 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Страница 14: ...14 FOR MORE INFO REFERENCE OIM MANUAL P N FSG MNL 00210...

Отзывы: