67
2022
Innovative Vehicle Solutions
DIAG++
Operator‘s Guide
DIAG++
Remote overload lamp
Select remote overload lamp on AUX 1 / 2 / 3 and click
on 'modify' button.
This gives a 24 V output when the trailer load goes
above the set limits. The following screen will appear to
modify the values required.
Note: Remote overload lamp works with only the Slave
ECU valve suspension unit in 3M full trailer systems.
Settings information
Function can be controlled / extended by several inputs.
OR
AUX output will change status if function OR any of
the related inputs are active.
AND
AUX output will change status, if the function AND all
related inputs are active.
24 V
Standard output: Function AND / OR logic HIGH ->
24 V to solenoid, otherwise 0 V.
0 V
Inverted output: Function AND / OR logic HIGH->
0 V to solenoid, otherwise 24 V.
*The output level can be adjusted independently of
input use!
*Possible inputs: Super AUX A / B/ C custom, general
purpose input (GPI) AUX 4 / 5
Stability lamp settings information
Function can be controlled / extended by several inputs.
OR
AUX output will change status if function OR any of
the related inputs are active.
AND
AUX output will change status, if the function AND all
related inputs are active.
24 V
Standard output: Function AND / OR logic HIGH ->
24 V to solenoid, otherwise 0 V.
0 V
Inverted output: Function AND / OR logic HIGH->
0 V to solenoid, otherwise 24 V.
*The output level can be adjusted independently of
input use!
*Possible inputs: Super AUX A / B / C custom, general
purpose input (GPI) AUX 4 / 5
Содержание DIAG++
Страница 1: ...Innovative Vehicle Solutions OPERATOR S GUIDE ...
Страница 4: ...4 Innovative Vehicle Solutions 2016 4 Innovative Vehicle Solutions 2022 Operator s Guide DIAG ...
Страница 14: ...14 Innovative Vehicle Solutions 2016 14 Innovative Vehicle Solutions 2022 Operator s Guide DIAG ...
Страница 97: ...97 2022 Innovative Vehicle Solutions DIAG Operator s Guide DIAG Notes ...