EB+ CAN Hub
Installation
Guide
22
Innovative Vehicle Solutions
2020
Ø150 max
100 min
B
Ø100 min
Sensor 1A
Sensor 1B
Solenoid
Sensor 1A
Sensor 1B
Solenoid
Excess cable
Excess cable must not be allowed to hang free, but
must be attached to the chassis to prevent damage due
to vibration and abrasion.
Cable lengths less than 1 m to be coiled into loops of
100 mm minimum and 150 mm maximum diameter.
Excess length which will not form a complete loop may
be left to hang in partial loops having a cable bend
radius of 50 mm minimum.
Cable lengths greater than 1 m to be coiled and then
flattened in the centre ‘B’ to produce a ‘dog bone’
shape.
The resulting loops at the end must have a minimum
bend radius of 50 mm. Cable ties are to be used to fix
the cable in the flattened loop shape.