5
●
Using vacuum function inoperative nozzle {N51-01(G), N51-05(G), N51-06(G)}
1. Retract the vacuum pipe to the shortest length using the vacuum pipe
control knob.
2. Tighten the nozzle mounting screw.
CAUTION
●
Pad
The pad does not last indefinitely. When it becomes deteriorated, replace it. Since exposure to
high temperatures causes it to deteriorate faster, Hakko recommends it be cooled after use.
2. Attach the pad.
a. Attach the pad.
b. Adjust the pad to an appropriate position.
Adjust the vacuum pipe so that the pipe and pad protrude as little as possible.
NOTE:
Letter G is marked on the
nozzle with the pipe guard.
←A
A
Pipe guard
CAUTION
The new N51-01/05/06 nozzle has a pipe
guard inside. These nozzles could not be
attached to HAKKO FR-810B when the vacuum
pipe is extended. Do not use excessive force.
CAUTION
CAUTION
When “G” is not marked on the nozzle, these nozzles do not
have space to blow hot air. using them with the HAKKO FR-810B
may result in danger.
●
Vacuum function inoperative nozzles. (Old nozzle)
A1124B, A1130, A1131, A1132, A1133, A1134, A1142B, A1183, A1190, A1191, A1192, A1325
These nozzles could not be attached to HAKKO FR-810B when the vacuum pipe is extended.
Do not use excessive force.
A1124, A1142
Do not use these nozzles with HAKKO FR-810B.
These nozzles do not have space to blow hot air,
using them with the HAKKO FR-810B may result in danger.
●
How to Use a old nozzle
Align the
projection part
, attach the old nozzle to the heater pipe.
There are two projection with
different heights. Align the
nozzle
screwing position
with
the higher projection part of
the pipe.
Projection part(high)
Projection part(low)
Screwing position
→
When attached in the wrong direction,
the nozzle could not be fully inserted
and can cause air leakage.
Make sure to attach the nozzle in the
correct direction.
CAUTION
M3×5
QFP nozzle
※When using the QFP nozzle, remove the
inside screw (M3 × 5) of the nozzle.
Projection part
Projection part
Projection part