background image

17

N51-05 Bent Single 1.5 x 3 (0.06 x 0.12)

①100℃

②200℃

③300℃

④400℃

⑤500℃

⑥600℃

Temp.

700

(1292

)

600

(1112

)

500

(932

)

400

(752

)

300

(572

)

200

(392

)

100

(212

)

0

(32

)

1           2           3           4           5           6           7           8           9

Air

①100℃

②200℃

③300℃

④400℃

⑤500℃

⑥600℃

N51-04  Single ø7.0 (0.28)

Temp.

700

(1292

)

600

(1112

)

500

(932

)

400

(752

)

300

(572

)

200

(392

)

100

(212

)

0

(32

)

1           2           3           4           5           6           7           8           9

Air

Содержание FR810-05

Страница 1: ...vacuum pipe Vacuum pipe control knob This knob controls the length of the vacuum pipe Pick up indicator The movement of the vacuum pipe can be checked here S START STOP button V VACUUM button Handpiec...

Страница 2: ...aximum airflow capacity CAUTION This product includes such features as electrically conductive plastic parts and grounding of the handpiece and station as measures to protect the device to be soldered...

Страница 3: ...by children without supervision To prevent accidents or damage to the HAKKO FR 810B be sure to observe the following Turn the power off when not in use or left unattended Do not strike the handpiece a...

Страница 4: ...he handpiece holder 1 Turn and loosen the knob that locks the handpiece holder 2 Slide the handpiece holder along the groove on the station in the direction of the arrow Turn the knob to lock the hand...

Страница 5: ...not have space to blow hot air using them with the HAKKO FR 810B may result in danger Vacuum function inoperative nozzles Old nozzle A1124B A1130 A1131 A1132 A1133 A1134 A1142B A1183 A1190 A1191 A119...

Страница 6: ...lly stopped The display will show indicating that the station is ready to start again Air Blow 1 Start Press the S button on the handpiece or START STOP button on the station to start blowing air Hot...

Страница 7: ...n Press the button Press the button 3 times When you want to leave the timer Press the button once Finished Vacuum Function Press the V Vacuum button on the handpiece The vacuum pump turns ON and the...

Страница 8: ...preset mode allowing the selection of temperature time and airflow from the options you define up to 5 temperature time airflow settings can be programmed Enter the parameter setting to change the mo...

Страница 9: ...fset mode Setting is available within the range of 90 F 50 C Each of the set values is displayed for two seconds and each change is finalized CAUTION If the total of a set value and an offset value ex...

Страница 10: ...ature is 650 and the timer setting is 150 seconds The HAKKO FR 810B has the following parameters Parameter No Parameter name selection Auto sleep ON OFF setting Auto shutoff ON OFF setting Setting mod...

Страница 11: ...t the password function is needed when moving to the temperature setting preset offset and air flow modes and set the password Auto shutoff time setting Set auto shutoff time The setting is available...

Страница 12: ...Auto shutoff ON OFF setting 1 Either or will be displayed if you press the button when is displayed 2 and will be switched alternately If you press the button 3 The display will return to if you press...

Страница 13: ...t the password function is needed when moving to the offset mode 9 Either without password or with password will be displayed if you press the button 10 If you press the button after selecting you wil...

Страница 14: ...hen is displayed 2 and will be switched alternately If you press the button 3 The display will return to if you press the button after selecting I Chain Preset setting 1 Either or will be displayed if...

Страница 15: ...shown to the under The hot air temperature may not reach the set temperature depending upon the combina tion of the nozzle and the set air flow In this case reduce the set temperature or the air flow...

Страница 16: ...752 300 572 200 392 100 212 0 32 1 2 3 4 5 6 7 8 9 Air N51 02 Single 4 0 0 16 100 200 300 400 500 600 100 200 300 400 500 600 N51 03 Single 5 5 0 22 Temp 700 1292 600 1112 500 932 400 752 300 572 200...

Страница 17: ...200 300 400 500 600 Temp 700 1292 600 1112 500 932 400 752 300 572 200 392 100 212 0 32 1 2 3 4 5 6 7 8 9 Air 100 200 300 400 500 600 N51 04 Single 7 0 0 28 Temp 700 1292 600 1112 500 932 400 752 300...

Страница 18: ...e to turn the power switch OFF and be careful of the following procedure when replacing the heating element B Measure the resistance value Normal heater resistance value Connect an ohmmeter across the...

Страница 19: ...it does not operate when the power switch is turned on is displayed is displayed is displayed WARNING Before checking the inside of the HAKKO FR 810B or replacing parts be sure to disconnect the power...

Страница 20: ...g Power cord 3 wired cord American plug B Power cord 3 wired cord SI plug Power cord 3 wired cord BR plug Inlet Pump Heat resistant pad Specifications 100 127V 220 240V U S A India 220V KTL 230V CE 23...

Страница 21: ...5126 Part Name Adapter for fixture C1392B Air guard assembly Specifications 2 With fixing bracket Optinal Parts 1 2 Assembly of the air guard Attach the air guard assembly Air guard assembly Screws wi...

Страница 22: ...14 BGA 12 12 4 5 0 18 4 5 0 18 7 0 28 7 0 28 9 0 35 11 0 43 13 0 51 13 0 51 15 0 59 16 0 63 16 0 63 18 0 71 19 0 75 19 0 75 21 0 83 23 0 91 25 0 98 28 1 1 30 1 18 36 1 42 9 0 35 11 0 43 15 0 59 18 0 7...

Страница 23: ...n as a rework system For usage details please refer to the instruction manual for each product Example Combination of HAKKO FR 810B Grip Fixture L Preheater HAKKO FR 870B and board holder HAKKO FR 870...

Страница 24: ...rd holder Grip Fixture M Grip Fixture L Specifications 2016 4 MA02820XZ160406 Tray Hex wrench 6 across flats Hex wrench 6 across flats O ring O ring 2016 HAKKO Corporation All Rights Reserved Test Equ...

Отзывы:

Похожие инструкции для FR810-05