10. PARTS LIST
8. MAINTENANCE / INSPECTION
A. Remove the heating element
1. Remove the 4 screws that attach the heater pipe to the handpiece. Remove the heater pipe.
2. Remove the mica, heat insulation fiber and insulation ring in the heater pipe.
3. Disconnect and remove the heating element.
B. Measure the resistance value
●
Normal heater resistance value
Connect an ohmmeter across the connector terminals (a).
The correct values are approximately: 14Ω (
±10%
100-110V), 17Ω (
±10%
120V), 41Ω (
±10%
220-240V).
If the resistance value is incorrect, replace the part.
●
Normal sensor resistance value
Connect an ohmmeter across the connector terminals (b). If the resistance value is ∞, replace the part.
Refer to the instructions included with the replacement part.
Pipe
CAUTION
Replacing the heating element is very dangerous. Be sure to turn the power switch OFF and be careful of
the following procedure when replacing the heating element.
(a)
(b)
Mica
Heat insulation fiber
Mica
Heat insulation fiber
Insulation ring
Insulation ring
CAUTION
Handle the heating element with care. Never touch the heating element wire!
● The unit does not operate when the
power switch is turned on.
● is displayed
● is displayed
● is displayed
9. TROUBLE SHOOTING GUIDE
WARNING
Before checking the inside of the HAKKO FR-810 or replacing parts, be sure to disconnect the power
plug. Failure to do so may result in electric shock.
Is the fuse blown?
Investigate why the fuse blew and then replace the fuse. If
the cause can not be determined, replace the fuse. If the fuse
blows again, send the unit in for repair.
Is the sensor broken?
Measure the resistance value of the sensor. When the resistance
value is ∞, replace the heater.
Is the heater broken?
Measure the resistance value of the heater. The corr
ect values are approximately: 14Ω (
±10%
100-110V), 17Ω (
±10%
120V), 41Ω (
±10%
220-240V). When the resistance value is not
within the normal range, replace the heater.
The fan may be broken. Replace the fan with a new one.
CHECK
:
ACTION
:
CHECK
:
ACTION
:
CHECK
:
ACTION
:
ACTION
:
2014.9
MA02638XZ140906
11. OPTIONAL PARTS (Nozzle)
①
②
③
④
⑤
⑥
⑦
Heat insulation fiber
Insulation ring
⑧
⑨
⑩
⑪
1
2
3
4
Item No.
①
②
③
④
Part No.
B5056
B5057
B2300
B5059
Part Name
FP pick-up
FP pick-up wire (SS)
Heat resistant pad
adapter
Specifications
With pick-up wire (SS)
×2
●
Optional parts
Item No.
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
Part No.
A5005
A5006
A5007
B5043
B5044
B5060
B5045
B5046
B5048
B5049
B5050
B5051
B5052
B5053
B5054
B2421
B2422
B2424
B2425
B2426
B2436
B3508
B3550
B3616
Part Name
Heating element
Heating element
Heating element
Joint hose
Fuse/250V-10A
Fuse/250V-6.3A
Pipe
Handle with cord assembly
Handpiece holder
Mica
P.W.B. / 100-127V
P.W.B. / 220-240V
Fan
Power unit
Power cord, 3 wired cord & American plug
Power cord, 3 wired cord but no plug
Power cord, 3 wired cord & BS plug
Power cord, 3 wired cord & European plug
Power cord, 3 wired cord & BS plug
Power cord, 3 wired cord & Australian plug
Power cord, 3 wired cord & Chinese plug
Power cord, 3 wired cord & American plug (B)
Power cord, 3 wired cord & SI plug
Power cord, 3 wired cord & BR plug
Specifications
100-110V
120.127V
220-240V
100-127V
220-240V
U.S.A.
India
220V KTL, 230V CE
230V CE, U.K.
China
●
HAKKO FR-810
Unit: mm (in.)
How to Use a old nozzle
1. Attach old nozzle to B5058 Conversion adaptor.
2. Attach B5058 (with old nozzle attached) to the heater pipe.
Copyright © 2014 HAKKO Corporation. All Rights Reserved.
OVERSEAS AFFILIATES
U.S.A.: AMERICAN HAKKO PRODUCTS, INC.
TEL: (661) 294-0090 FAX: (661) 294-0096
Toll Free (800)88-HAKKO
4 2 5 5 6
http://www.hakkousa.com
HONG KONG: HAKKO DEVELOPMENT CO., LTD.
TEL: 2811-5588 FAX: 2590-0217
http://www.hakko.com.hk
E-mail:[email protected]
SINGAPORE: HAKKO PRODUCTS PTE LTD.
TEL: 6748-2277 FAX: 6744-0033
http://www.hakko.com.sg
E-mail:[email protected]
Please access to the following address for the other Sales affiliates.
http://www.hakko.com
HEAD OFFICE
4-5, Shiokusa 2-chome, Naniwa-ku, Osaka 556-0024 JAPAN
TEL:+81-6-6561-3225 FAX:+81-6-6561-8466
http://www.hakko.com E-mail:[email protected]
B5058 Conversion adapter
N51-05
Bent single 1.5×3 (0.06×0.12)
N51-04
Single ø7 (0.28)
N51-03
Single ø5.5 (0.22)
N51-01
Single ø2.5 (0.1)
N51-02
Single ø4 (0.16)
ø7 (0.28)
ø5.5 (0.22)
ø2.5 (0.1)
ø4 (0.16)
1.5
(0.06)
45°
3
(0.12)