background image

SMD Rework Station

Instruction Manual

Thank you for purchasing the HAKKO FR-810 SMD Rework Station. 

This unit features digital control and display of hot air temperature.

Please read this manual before operating the HAKKO FR-810.

Keep this manual readily accessible for reference.

1. PACKING LIST AND PART NAMES

2. SPECIFICATIONS

Power cord

HAKKO FR-810 

station

Handpiece

Nozzle

 

Handpiece holder

handpiece holder 

attachment plate

HAKKO FR-810 station

Handpiece holder

FP pick-up 

{with 

FP pick-up wire

(SS)}

Heat resistant pad

Power cord

Nozzle

 N51-02 (ø4)

Instruction manual

1
1
1
1

1
1
1

電路板

水平支架

連接器

插座

 Handpiece

Power consumption 

Total length (w/o cord)
Weight (w/o cord)

Power consumption 

* This product is protected against electrostatic discharge.

* Specifications and design are subject to change without 

notice.

 Station

Power consumption 
Capacity (Airflow)
Control temperature 
Outer dimensions 

Weight

30 W

1 - 9 (5 - 115L/min*)

50 - 600℃ (120 - 1120℉)

160(W) × 145(H) × 220(D) mm

(6.3 × 5.7 × 8.7 in.)

1.5 kg (3.3 lb.)

* Airflow capacity is rated as free flowing.  Restrictions 

created by various nozzles may reduce the maximum 

airflow capacity.

FP pick-up wire

(SS)

FP pick-up

 Air indicator

Temp/Time indicator

Heat resistant pad

CAUTION

This product includes such features as electrically 

conductive plastic parts and grounding of the 

handpiece and station as measures to protect the 

device to be soldered from the effects of static 

electricity. Be sure to observe the following  

instructions:
1. The handle and other plastic parts are not 

insulators, they are conductors. When replacing 

parts or repairing, take sufficient care not to 

expose live electrical parts or damage 

insulation materials. 

2.  Be sure to ground the unit during use.

Please check to make sure that all items

listed below are included in the package.

100V-670W 110V-810W 120V-790W
220V-1070W 230V-1170W 240V-1270W

250 mm (9.8 in.)

180 g (0.40 lb.)

100V-700W 110V-840W 120V-820W
220V-1100W 230V-1200W 240V-1300W

The front panel of HAKKO FR-810 includes five operation buttons. 

 - Used to start or stop the station.

•Pressing this button when the forced cool down bypass is 

enabled will turn the airflow off and stop the cooling process.

 - Used for changing values. 

•Pressing this button when using Preset Mode will cause the 

preset selection screen to appear.

 - Used for changing values. 

•Hold this button for at least two seconds to enter the Offset 

Mode.

 - Used for finalizing entered values and checking settings.

•Hold this button for at least two seconds to display the 

temp/timer screen. 

 - Used to set air flow. 

When setting the airflow, you may press        or        to 
finalize your airflow setting value.

4. INITIAL SETUP

A.  Station assembly

  Attach the handpiece holder.

1. Turn and loosen the knob that locks the handpiece holder.

2. Slide the handpiece holder along the groove on the station in the direction of 

the arrow. Turn the knob to lock the handpiece holder in place.

B. Attaching a nozzle
Aligning the groove on the nozzle with the tabs on the 

heater pipe and slide the nozzle onto the heater pipe. 

Turn the nozzle to lock it in place.

* The handpiece holder can be attached to either side of 

the station by removing the handpiece holder attachment 

plate and attaching it to the opposite side of the handpiece 

holder.

● 

Controls and displays

When powered, the temperature of the hot air and the nozzle will become extremely hot, reaching 

a maximum temperature of 600℃ (1120℉). Be sure of the following to avoid possible burns / fires :

 

Do not direct the hot air toward personnel or touch the metal 

parts near the nozzle.

 

Do not allow the nozzle to come close to, or touch, flammable materials.

 

Inform others in the area that the unit is hot and should not be touched.

 

Turn the power off and allow the unit to cool when changing 

parts or storing the HAKKO FR-810.

 

This appliance can be used by children aged from 8 years and 

above and persons with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge if they have 

been given supervision or instruction concerning use of the 

appliance in safe way and understand the hazards involved.

 

Children shall not play with the appliance.

 

Cleaning and user maintenance shall not be made by 

children without supervision.

● 

To prevent accidents or damage to the HAKKO FR-810, be sure to observe the following:

● 

Turn the power off when not in use, or left unattended.

● 

The unit is for a counter or workbench use only.

● 

Do not strike the handpiece against hard surfaces or otherwise subject it to physical shock.

● 

Be sure the unit is grounded. Always connect power to a grounded receptacle.

● 

Do not modify the unit.

● 

Use only genuine HAKKO replacement parts.

● 

Do not allow the HAKKO FR-810 to become wet, or use it when hands are wet.

● 

Remove the power cord by holding the plug - not the cord.

● 

Be sure the work area is well ventilated.

To avoid damage to the unit, do not turn the power switch OFF until the pump stops automatical by 

cooling down after use until           appears on the display.

3. WARNINGS, CAUTIONS AND NOTES

Warnings, cautions and notes are placed at critical points in this manual to direct the operator’s 

attention to significant items. They are defined as follows:

CAUTION :

 

Failure to comply with a CAUTION may result in injury to the operator, or damage to the 

 

items involved. 

WARNING:

 

Failure to comply with a WARNING may result in serious injury or death.

NOTE :

 

A NOTE indicates a procedure or point that is important to the process being described.

WARNING

CAUTION

5. OPERATION

  Air Blow

1. Start

Press the “S” button on the handpiece or          (START/STOP) button on the station to start blowing air. 

Hot air blows out of the tip of the nozzle. Hot air temperature is controlled according to the temperature 

setting.

2. Stop

Press the “S” or          button again. Power to the heater is shut off and cooling begins. When the 

temperature falls to 100°C (200°F), or after 1.5 minutes of cooling, air blow is automatically stopped. The 

display will show               indicating that the station is ready to start again.

 

Setting of the air flow
Pressing the AIR button in the station causes the LED for AIR display to blink and allows 
you to change air flow. The air flow setting range is 1 to 9.
Actual airflow may be affected by the size and shape of the nozzle(s) used.

WARNING

Do not stop the hot air by turning the power switch OFF.

If power is turned off after use, there will be no cool-down. To avoid damage to the equipment, do not turn 

the power switch OFF until            appears on the display.

4. INITIAL SETUP

CAUTION

When not in use, place the handpiece 

on the holder.

C. Electrical connection and power ON

1. Insert the power cord into the receptacle on the rear panel of the station. 

2. Place the handpiece on the holder. 

3. Plug the other end of the power cord into a grounded 

wall socket.

4. Turn the power switch ON.

CAUTION

This product is protected against electrostatic 

discharge. Be sure the unit is grounded.

“S” 

button

START/STOP

button

Example:

 Changing the air flow setting from 5 to 7

Example : When the set temperature is 300°C and the timer setting is ---.

Finished

  Setting/Changing the Temperature and Timer

NOTE:  

After accepting the value for the ones digit for temperature, you will have the option to set the timer 

starting over with the hundreds digit.

The factory default : "Temperature 300℃ / 540℉" "Timer 

ーーー (

No setting

)

"

Setting the 

Timer

Press the         or 

button 5 times.

Each of the set values is displayed for 

one second, and each change is finalized. 

The rim of the handpiece 

must rest on the area 

circled in the illustration.

Press the         

button.

Press the         

button twice.

Press the         

button once.

Press the         

button twice.

Press the         

button.

Press the         

button.

Press the         

button.

Press the         

button.

Press the         

button.

Press the         

button.

Press the         or      

         button.

Press and hold the 
      button for more 
than one second.

Press the          

button 3 times.

1. Setting the Temperature (from 300℃ to 450℃)

2. Setting the Timer (from --- to 130sec)

* When you want to leave the timer "

ーーー

".

Press the         

button once.

Finished

Отзывы: