![Hakko Electronics FR-810 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/hakko-electronics/fr-810/fr-810_instruction-manual_3315136002.webp)
5. OPERATION
In addition to the procedure described remove above, HAKKO FR-810 includes a preset mode allowing the
selection of temperature, time, and airflow from the options you define (up to 5 temperature/time/airflow
settings can be programmed). Enter the parameter setting to change the mode.
(Please refer to [
●
Changing Parameter Settings])
Initial preset settings:
The initial number of active presets is set to 5 at the factory.
The default selected preset is set to at the factory.
Example : Changing preset selection from preset No.1 to No.3.
Control will begin with new preset setting.
The procedure for making changes to the preset temperatures, timer and air flow is the same as the
“Setting/Changing the Temperature and Timer” and “Setting of the air flow”.
Example:
Changing the offset setting from 0℃ to -30℃
*Preset selection screen
●
Preset mode
●
Offset mode
{Setting is available within the range of ±50°C (90°F)}
Be displayed
alternately.
Be displayed
alternately.
Each of the set values is displayed for two seconds,
and each change is finalized.
Temp. : 100℃ (212℉) Timer : “−−−” Air flow : 5
Temp. : 300℃ (572℉) Timer : “−−−” Air flow : 5
Temp. : 500℃ (932℉) Timer : “−−−” Air flow : 5
Temp. : 200℃ (392℉) Timer : “−−−” Air flow : 5
Temp. : 400℃ (752℉) Timer : “−−−” Air flow : 5
CAUTION
If the total of a set value and an offset value exceeds 600°C, the exceeding portion in the offset value is
not effective.
* Timer function
In this product, setting the timer allows you to control the time during which hot air is blown.
Either of the following two modes is selectable by parameter setting: Open Timing in which count is
started from the time when temperature reaches the set temperature and Closed Timing in which count is
started upon start. The timer setting range is 001 to 999 seconds.
(When not using the timer function, select “---”. When set in the timer setting “000” , don't work. )
●
Restriction on setting changes (Password function)
It is possible to restrict certain setting changes to the unit.
There are three choices for the password setting.
Enter the parameter settings to change the mode. (Please refer to [
●
Changing Parameter Settings])
○
: You can make changes without entering a password.
△
: You can choose whether or not a password is needed to make changes.
×
: A password is required to make changes.
Select and input three letters for password
from six letters on the right.
Example: The procedure for changing the set temperature when the unit is restricted by a password.
(Password is "AbC")
The unit will move to the change setting screen for each mode after entering the password. Please change
the setting for each mode according to the procedure covered in this manual.
The letters
for password
Switch to the parameter setting mode
Switch to the temperature setting mode
Switch to the preset selection mode
Switch to the offset setting mode
Make airflow adjustments
0 : Open
○
○
○
○
○
1 : Partial
×
△
△
△
△
2 : Restricted
×
×
×
×
×
Press the
button once.
Press the
button twice.
Press the
button.
Press and hold the
button for more
than one second.
Press and hold the
button for more
than one second.
Press the
button once.
Press the
button once.
Press the
button twice.
Press the
button three times.
Press the
button thrice.
Press the
button.
Press the
button.
Press the
button.
Press the
button.
Press the
button.
Press the
button.
CAUTION
・
If the password you entered is incorrect, the display will show
three dashes for you to re-enter the password.
・
If you enter the password incorrectly twice in a row, the display
will return to the previous screen.
5. OPERATION
In this station, when you turn on “Preset mode” and “Chain Presets function” in the parameter settings
and set the timer for each preset, available presets are called in from “P-1” to “P-5” allowing you to
simulate up to a 5 step rework profile. (The number of available presets changes depending on the setting.
Refer to “6. PARAMETER SETTING”.)
When the handpiece is placed in the holder, the automatic sleep function starts working (by default).
Pressing the “S” button ( button) in this state will not turn on the station. If the handpiece is placed
in the holder while it is blowing hot air, start of automatic cooling is forced before the stop of operation.
The auto shutoff function works by default after the station is idle for 30 minutes and it automatically
enters a power save state.
With this function enabled, if you press the “S” button ( button) again during cooling, cooling is stopped.
This function is used when working temperature is low and you do not have to wait until automatic stop is
made. When the set temperature is 380°C or more, the function is unavailable.
●
Chain Presets function
●
Auto sleep function
●
Auto shutoff function
●
Forced cooling bypass function
●
Check of settings
Other main functions
CAUTION
When installing this station, do not place flammable substances behind the outlet of the handpiece. If
the handpiece is placed in the iron holder while blowing hot air, serious accidents such as fire may be
caused by hot air.
Temp. : 100℃ (212℉) Timer : “200” Air flow : 2
Temp. : 300℃ (572℉) Timer : “000” Air flow : 5
Temp. : 500℃ (932℉) Timer : “030” Air flow : 6
Temp. : 200℃ (392℉) Timer : “100” Air flow : 3
Temp. : 400℃ (752℉) Timer : “050” Air flow : 5
Temp. : 100℃ (212℉) Timer : “200” Air flow : 2
Temp. : 300℃ (572℉) Timer : “050” Air flow : 5
Temp. : 500℃ (932℉) Timer : “030” Air flow : 6
Temp. : 200℃ (392℉) Timer : “- - -” Air flow : 3
Temp. : 400℃ (752℉) Timer : “050” Air flow : 5
Pressing the button once allows you to check the settings of the set temperature and set
time in this order.
6. PARAMETER SETTING
The HAKKO FR-810 has the following parameters:
Parameter No.
Parameter name
℃ / ℉ selection
Auto sleep ON/OFF setting
Auto shutoff ON/OFF setting
Setting mode selection
The number of preset *
Password setting
Temperature setting mode **
Preset selection mode**
Offset setting mode**
Air flow mode**
Password***
Auto shutoff time setting
Timer mode
Forced cooling bypass
Preset connection
ON/OFF
setting
Value
C/F
0: OFF / 1: ON
0: OFF / 1: ON
0:
Normal
/ 1:
Preset
(2 pcs)〜 (5 pcs)
0:
Open
/ 1:
Partial
/ 2:
Restricted
:○ / :×
:○ / :×
:○ / :×
:○ / :×
Select three letters
30
〜
60min
(
Set in units of minutes
)
o: Open Timing / c: Closed Timing
0: OFF / 1: ON
0: OFF / 1: ON
Initial value
℃
1
1
0
0
-
30
o
0
0
Example : When the set temperature is 350°C and the timer setting is 150 seconds.
* It is displayed only when "1:Preset mode" is selected in the setting mode.
** It is displayed only when "1:Custom" is selected in the password setting.
***It is displayed only when either "1:Custom" or "2:valid" is selected in the password setting.
A preset in which “000” is set in the timer setting is skipped and the next preset is automatically started.
(In case of the example 1, this setting corresponds to )
Unless you stop blowing hot air by pressing the “S” or ( ) button manually, the unit will keep up
the state if you set “---” in the timer setting. (In case of the example 2, this setting corresponds to )
The unit will not move to next step.
Example 1
)
Operation : 100℃ (200sec)
→
200℃ (100sec)
→
400℃ (50sec)
→
500℃ (30sec)
Example 2
)
Operation : 100℃ (200sec)
→
200℃
6. PARAMETER SETTING
● :
℃ or ℉ temperature display seletion
The displayed temperature can be switched between Celsius and Fahrenheit.
● :
Auto sleep ON/OFF setting
Select whether you will activate the auto sleep function.
● :
Auto shutoff ON/OFF setting
Select whether you will activate the auto shut off function.
● :
Setting mode selection
Temperature setting can be switched between the normal mode and the preset mode.
If selecting the preset mode, you will be asked for the number of preset to have available for programming.
Press the or button to set the number.
● :
Password setting
Select "Open", "Partial" or "Restricted" for password setting. If selecting the Restricted, perform the setting
for password. If selecting partial, choose whether or not the password function is needed when moving
to the temperature setting, preset, offset, and air flow modes and set the password.
● :
Auto shutoff time setting
Set auto shutoff time. The setting is available within 30 to 60 minutes in increments of one minute.
● :
Timer mode selection
Timer mode setting can be switched between the Opened timing and the Closed timing modes.
● :
Forced cooling bypass
Specify whether or not to enable the function that allows you to force the termination of cooling after
completion of work. Forced termination in high temperature may cause premature failure of the heating
element. Do not use the function except for work in low temperature.
● :
Chain Preset setting
Select whether you will activate the Chain Preset function. If you turn on “Preset mode” and “Chain Preset
function”, available presets are called in sequence from “P-1” to “P-5” allowing you to simulate up to a 5 step
rework profile.
●
Parameter entering mode
1. Turn off the power switch.
2. Turn on the power switch while pressing the button.
3. When the display shows , the station is in parameter entering mode.
4. You can switch the parameter No. by pressing the or .
A. ℃ or ℉ temperature display selection
1. Either
or will be displayed if you press the button when is displayed.
2. and will be switched alternately If you press the ( ) button.
3. The display will return to if you press the button after selecting.
B. Auto sleep ON/OFF setting
1. Either
or will be displayed if you press the button when is displayed.
2. and will be switched alternately If you press the ( ) button.
3. The display will return to if you press the button after selecting.
C. Auto shutoff ON/OFF setting
1. Either
or will be displayed if you press the button when is displayed.
2. and will be switched alternately If you press the ( ) button.
3. The display will return to if you press the button after selecting.
D. Setting mode selection
1. Either
or will be displayed if you press the button when is displayed.
2. (The normal mode) and (The preset mode) will be switched alternately, if you press
the ( ) button.
3. The display will return to if you press the button after selecting.*
* If you select the preset mode, the display will move to the preset selection screen.
4.The number of active preset will be displayed If you press the button at 3.
(Example : If the number is three, is displayed.)
5. Press the ( ) button to change the value and select the number of active preset you required.
The unit will accept values from 2 through 5.
6. The display will return to if you press the button after selecting.