background image

13

8.  TROUBLE SHOOTING GUIDE

 WARNING

Before checking the inside of the HAKKO FN-1010 or replacing parts, be sure to disconnect the power 

plug. Failure to do so may result in electric shock.

The unit does not operate when 

the power switch is turned on.

CHECK

  Is the power cord and/or the connection plug disconnected?

ACTION

  Connect it.

CHECK

  Is the fuse blown?

ACTION

   Investigate why the fuse blew and then replace the fuse. If the cause can not be 

determined, replace the fuse. If the fuse blows again, send the unit in for repair.

The tip does not heat up.

The 

Sensor Error” is displayed.

CHECK

   Is the tip for HAKKO FN-1101 soldering iron?

ACTION

   Turn the power switch OFF and insert the genuine HAKKO FN-1101 tip. Turn the 

power switch ON.

CHECK

  Is the tip inserted properly?

ACTION

  Insert the tip completely.

CHECK

  Is the connection cord and/or the heater/sensor broken?

ACTION

   See the appropriate section  

of this manual regarding  

how to check the connection cord  

and/or the heater/sensor  
for breakage. 

Measure the resistance of the heater and sensor while

at room temperature, and it should be 

5Ω±10%.

Solder does not wet the tip.

CHECK

  Is the tip temperature too high?

ACTION

  Set the appropriate temperature.

CHECK

  Is the tip contaminated with oxide?

ACTION

  Remove the oxide (see “7. MAINTENANCE”.).

The tip temperature is too high.

CHECK

  Is the connection cord broken?

ACTION

  If the connection code is broken, replace the HAKKO FN-1101.

CHECK

  Is the entered offset value correct?

ACTION

  Enter the correct value.

The tip temperature is too low.

CHECK

  Is the tip contaminated with oxide?

ACTION

  Remove the oxide (see “7. MAINTENANCE”.).

CHECK

  Is the entered offset value correct?

ACTION

  Enter the correct value.

The low-temperature alarm 

tolerance error occurs frequently.

CHECK

  Is the tip too small for the items to be soldered?

ACTION

  Use a tip with a larger thermal capacity.

CHECK

  Is the setting value for the low-temperature alarm tolerance too low?

ACTION

  Increase the setting value.

Heater terminal short circuit error 

is displayed.

CHECK

  Is the tip for HAKKO FN-1101 soldering iron?

ACTION

   Turn the power switch OFF and insert the genuine HAKKO FN-1101 tip. Turn the 

power switch ON.

Содержание FN-1010

Страница 1: ...ct is a soldering iron with added functions for use with peripheral equipment such as thermometer Please read the manual carefully before operating the HAKKO FN 1010 Please keep this manual readily ac...

Страница 2: ...tip 4 5 2 2 Removing tip 5 5 2 3 About tips 5 5 3 Station 5 6 OPERATION 6 6 1 Setting changing the temperature 6 6 2 Selecting a preset temperature 7 6 3 Setting changing the offset 7 6 3 1 Direct in...

Страница 3: ...measured using the HAKKO FG 101 thermometer HAKKO FN 1101 soldering iron Power consumption 95W 21V Tip to ground resistance 2 Tip to ground potential 2mV Length of cord 1 2 m Length w o cord 180 mm wi...

Страница 4: ...unter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if t...

Страница 5: ...item selection During normal operation Opens setting screen In setting screen Cancels input value and moves to previous screen During normal operation In normal screen switches between digital display...

Страница 6: ...e and retighten the screws to secure it in place 2 Insert the cleaning wire A1561 into the tip cleaner FT401 81 and attach the tip cleaner to the iron holder FH210 81 Note It is possible to switch the...

Страница 7: ...the Tip Info screen Refer to 6 7 Load repetition count alarm 5 3 Station CAUTION When connecting or disconnecting the soldering iron cord to from the receptacle always be sure to switch the power off...

Страница 8: ...r changed by the following steps The settable temperature range is 50 450 120 840 F Input Time Date 2018 01 01 00 00 1 With the normal screen shown press the button The menu screen will appear Select...

Страница 9: ...or button to select the desired Preset No After selecting press the button The selection will be stored in the internal memory and after the new temperature setting has been displayed heater control w...

Страница 10: ...AUTO SEND button to send the measured data to the IR receptor of the FN 1010 Note For details on using the thermometer equipped with IR transfer function refer to the instruction manual for the thermo...

Страница 11: ...ithin the set range it will be judged as passed If it is outside the set range temperature measurement and sending will be performed repeatedly for the previously set number of retries Note If the mea...

Страница 12: ...om the list and then press the button Temp Set Auto Cal Auto Cal Info Tip Info Load Detection Preset Temp Offset Temp 400 OFF 00 1 2018 03 23 17 15 P 2 2018 03 23 17 13 F 3 2018 03 23 17 13 F 4 2018 0...

Страница 13: ...instruction manuals available from the HAKKO Document Portal Please download the desired documents from there https doc hakko com 3 The count alarm value input screen will be shown Select ON and pres...

Страница 14: ...with fresh solder 4 Turn the power OFF and remove the tip using the heat resistant pad Set the tip aside to cool 5 Remaining oxides such as the yellow discoloration on the tip shaft can be removed wi...

Страница 15: ...nsor for breakage Measure the resistance of the heater and sensor while at room temperature and it should be 5 10 Solder does not wet the tip CHECK Is the tip temperature too high ACTION Set the appro...

Страница 16: ...TE LTD TEL 6748 2277 FAX 6744 0033 http www hakko com sg E mail sales hakko com sg Please access to the following address for the other Sales affiliates http www hakko com HEAD OFFICE 4 5 Shiokusa 2 c...