background image

12

7.  MAINTENANCE

Performing proper and periodical maintenance extends the products life and contributes to use it always in a 

good condition. Efficient soldering depends upon the temperature, the quality and quantity of the solder and flux. 

Apply the following service procedure as dictated by the conditions of the usage.

 WARNING

Since the soldering iron can reach a very high temperature, please work carefully. Except the case 

especially indicated, always turn the power switch OFF and disconnect the power plug before 

performing any maintenance procedure.

 CAUTION

NEVER file the tip to remove oxides!

1. 

Set the temperature to 250°C. (482°F.)

2. 

When the temperature stabilizes, clean the tip (see “Cleaning”, below) and check the condition of the tip. If the 

tip is badly worn or deformed, replace it.

3. 

If the solder plated part of the tip is covered with black oxide, apply fresh solder, containing flux, and clean the 

tip again.

Repeat until all the oxide is removed, then coat the tip with fresh solder.

4. 

Turn the power OFF and remove the tip, using the heat resistant pad. Set the tip aside to cool.

5. 

Remaining oxides, such as the yellow discoloration on the tip shaft, can be removed with isopropyl alcohol.

— Notes —

Tip temperature

High temperatures shorten tip life and may cause thermal shock to components. 

Always use the lowest possible temperature when soldering. The excellent thermal 

recovery characteristics of the HAKKO FN-1010 ensure effective soldering at low 

temperatures.

Cleaning

Always clean the soldering tip before use, to remove any residual solder or flux 

adhering to it. Use the tip cleaner. Contaminants on the tip have many deleterious 

effects, including reduced heat conductivity, which contribute to poor soldering 

performance.

After use

Always clean the tip and coat it with fresh solder after use. This guards against 

oxidation.

When the unit is 

not being used 

and the auto 

power shutoff is 

not active.

Never allow the unit to idle at a high temperature for extended periods. This will allow 

the tip to become oxidized. Turn the power switch OFF. If it is to be out of service for 

several hours, it is advisable to pull the power plug as well.

Содержание FN-1010

Страница 1: ...ct is a soldering iron with added functions for use with peripheral equipment such as thermometer Please read the manual carefully before operating the HAKKO FN 1010 Please keep this manual readily ac...

Страница 2: ...tip 4 5 2 2 Removing tip 5 5 2 3 About tips 5 5 3 Station 5 6 OPERATION 6 6 1 Setting changing the temperature 6 6 2 Selecting a preset temperature 7 6 3 Setting changing the offset 7 6 3 1 Direct in...

Страница 3: ...measured using the HAKKO FG 101 thermometer HAKKO FN 1101 soldering iron Power consumption 95W 21V Tip to ground resistance 2 Tip to ground potential 2mV Length of cord 1 2 m Length w o cord 180 mm wi...

Страница 4: ...unter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if t...

Страница 5: ...item selection During normal operation Opens setting screen In setting screen Cancels input value and moves to previous screen During normal operation In normal screen switches between digital display...

Страница 6: ...e and retighten the screws to secure it in place 2 Insert the cleaning wire A1561 into the tip cleaner FT401 81 and attach the tip cleaner to the iron holder FH210 81 Note It is possible to switch the...

Страница 7: ...the Tip Info screen Refer to 6 7 Load repetition count alarm 5 3 Station CAUTION When connecting or disconnecting the soldering iron cord to from the receptacle always be sure to switch the power off...

Страница 8: ...r changed by the following steps The settable temperature range is 50 450 120 840 F Input Time Date 2018 01 01 00 00 1 With the normal screen shown press the button The menu screen will appear Select...

Страница 9: ...or button to select the desired Preset No After selecting press the button The selection will be stored in the internal memory and after the new temperature setting has been displayed heater control w...

Страница 10: ...AUTO SEND button to send the measured data to the IR receptor of the FN 1010 Note For details on using the thermometer equipped with IR transfer function refer to the instruction manual for the thermo...

Страница 11: ...ithin the set range it will be judged as passed If it is outside the set range temperature measurement and sending will be performed repeatedly for the previously set number of retries Note If the mea...

Страница 12: ...om the list and then press the button Temp Set Auto Cal Auto Cal Info Tip Info Load Detection Preset Temp Offset Temp 400 OFF 00 1 2018 03 23 17 15 P 2 2018 03 23 17 13 F 3 2018 03 23 17 13 F 4 2018 0...

Страница 13: ...instruction manuals available from the HAKKO Document Portal Please download the desired documents from there https doc hakko com 3 The count alarm value input screen will be shown Select ON and pres...

Страница 14: ...with fresh solder 4 Turn the power OFF and remove the tip using the heat resistant pad Set the tip aside to cool 5 Remaining oxides such as the yellow discoloration on the tip shaft can be removed wi...

Страница 15: ...nsor for breakage Measure the resistance of the heater and sensor while at room temperature and it should be 5 10 Solder does not wet the tip CHECK Is the tip temperature too high ACTION Set the appro...

Страница 16: ...TE LTD TEL 6748 2277 FAX 6744 0033 http www hakko com sg E mail sales hakko com sg Please access to the following address for the other Sales affiliates http www hakko com HEAD OFFICE 4 5 Shiokusa 2 c...