3. Dismantle the product as shown on the exploded draw-
ing.
4. Clean all oil and grease residues off all components with
an ester-free, non-polar, soft, lint-free cloth and check
for visible signs of damage.
5. Assemble the product in accordance with the exploded
drawing and lubricate during assembly [see »Lubricating
the product« chapter]. Pay attention to the following dur-
ing assembly:
Replace worn or damaged fixing screws.
Tighten all fixing screws to the specified tightening
torque [see nomenclature and/or »Screw tightening
torques« chapter]. When tightening the screws, do
so evenly to prevent any distortion under load.
Only apply lubricant to the mechanical mating sur-
faces. Pay attention to notes about lubricants [see
»Use of lubricants« chapter].
Avoid too much lubricant on the locating face be-
cause this can cause face run-out errors.
Apply grease to the sealing elements [for example
O-rings, rectangular rings] and sealing surfaces.
Pay attention to notes about greases [see »Use of
lubricants« chapter].
Before installing the CENTREX ring, apply a light
coating of grease to its contact surface.
6. Install the clamping device on the product [see »Instal-
lation of the clamping device« chapter].
11.4 Visual inspection
Perform a daily visual inspection of the product to identify
any damage to the product at an early stage.
Check the product for cracks and damage.
The rubber on the CENTREX ring also needs to be exam-
ined for cracks and signs of damage.
A check is also required to ensure that all fixing screws are
tightened down.
If damage is detected, the relevant components must be ex-
changed immediately for genuine spare parts from the man-
ufacturer.
Complete cleaning of the product is required if heavily soiled
[see »Cleaning« chapter].