background image

Preface

Dear customer,
Thank you for choosing our product.
The Hailo TOPlift CCV is an enhanced version of the Hailo TOPlift L.
The CCV (cold climate version) enables operation of the service lift to temperatures as low as

-35°C.
This manual describes the distinctive features and enhancements of the Hailo TOPLift CCV and is

valid only together with the original operating instructions of the Hailo TOPlift L.
You will find the operating instructions in the service lift.

Read the operating instructions!
Observe the notices regarding safety. Follow all applicable safety and operating

instructions.

Always keep this supplement together with the operating instructions in the service lift.

The end user must ensure the product is handled correctly through the fol-

lowing:

Correct operation by trained personnel

Maintenance and inspection of the service lift at the prescribed intervals

Creation of an emergency plan

Machine described:

Hailo TOPlift CCV

Language: EN

Addition to the original operating instructions
(supplement to a complete machine)

Revision:

 

Number, date, revision

Initial generation 01, 2013-10

We at Hailo Wind Systems wish you every success in your work!

This manual is valid only in connection with the original operating instructions.

You will find the operating instructions in the service lift.

The manufacturer's warranty for all components is two years, provided that the technical docu-

mentation is observed.

Adhere to the stipulated schedules for periodic tests and inspections.

Warranty

Schedules

Preface

• TOPlift CCV •

 

4

Содержание TOPlift CCV

Страница 1: ...Read the instructions prior to performing any task Supplement to the operating instructions Valid only in connection with the orig inal operating instructions Hailo TOPlift CCV...

Страница 2: ...upport for this device Hailo reserves the right without prior notice to make changes to this manual and the product it describes The content of this manual does not include any contractual or other ob...

Страница 3: ...Table of contents 1 Preface 4 2 Introduction 6 3 Safety 7 4 Operation 9 5 Maintenance 11 Table of contents TOPlift CCV 3...

Страница 4: ...n the service lift The end user must ensure the product is handled correctly through the fol lowing Correct operation by trained personnel Maintenance and inspection of the service lift at the prescri...

Страница 5: ...s and maintenance must be performed according to the specifications of the manufac turer Mechanical components must be checked for proper functioning as well as for wear or damage and replaced if nece...

Страница 6: ...in the service lift n Temperature measurement in the arrester device n Heating mat on the back of the arrester device n Temperature measurement in the switch cabinet n Switch cabinet heater n Lock mec...

Страница 7: ...to carry voltage even with the main switch turned off Never perform work on the control unit if it is under voltage Switch the voltage supply to the service lift off if necessary A temperature sensor...

Страница 8: ...the lift is now operational The Hailo TOPlift CCV is equipped with a special shutter door lock 1 This safety device prevents the shutter door from opening during ascent or descent as well as when stop...

Страница 9: ...utes WARNING Temperature settings Never change the temperature settings on the controls The proper functioning of safety related components will otherwise be jeopardised You can find the correct setti...

Страница 10: ...hment points in the cabin ceiling with a connecting device component of the personal protective equipment PPE to prevent falls DANGER Caution danger of falling If you are not secured with your persona...

Страница 11: ...travel path be travelled The structure should therefore prior to beginning the maintenance work be placed in an operating state which allows climbing of the tower n Maintenance work may only be carri...

Страница 12: ...rk For maintenance and repair work performed on the electrical system the entire machine must be switched free of current on the lowest level by means of the main switch on the switch cabinet or with...

Страница 13: ...the main switch turned off Many areas of the control unit continue to carry voltage even with the main switch turned off Never perform work on the control unit if it is under voltage Switch off the vo...

Страница 14: ......