Domestic air conditioner
11.4.9 Overheat Protection For Discharge Temperature
Electrify the machine again and turn it on with the remote controller,
then measure the temperature at the exhaust temperature sensor of
the compressor on the outdoor unit
the temperature exceeds
110
ć
shortly after the
machine starts up?
1) The cryogen may have been leaked during
installation, or there may be leakage in the piping
system.
2) There may be other causes to make the exhaust
temperature too high.
Malfunctions occur after running for some time even
though the measured temperature is below 110
ć
. Pull
out the exhaust sensor and measure its resistance at
standard temperatures according to the
resistance-temperature table
the results deviate
much?
The sensor is damaged. Replace the sensor
with a new one.
The outdoor mainboard is damaged and needs be
replaced
YES
NO
NO
YES
Method of
malfunction detection
Malfunction detection
conditions
Troubleshooting
The Discharge temperature control is checked with the temperature being detected by
the Discharge pipe thermistor
when the compressor discharge temperature is above 110
ć
Ŷ
Electronic expansion valve defective
Ŷ
Faulty thermistor
Ŷ
Faulty PCB
Supposed causes
* Caution
Be sure to turn off power switch before connect or disconnect connector, or else
parts damage may be occurred.
LED1 flash 8 times
Outdoor diplay
40
Содержание N-Series
Страница 47: ...Circuit diagrams Domestic air conditioner 12 Circuit diagrams 45 ...
Страница 48: ...Circuit diagrams Domestic air conditioner 46 ...
Страница 51: ...Removal of procedure 1 Removal of Air Filter 1 Domestic Air Condition ...
Страница 54: ...Removal of procedure three two HOOKS 4 Domestic Air Condition ...
Страница 55: ...Removal of procedure 3 Removal of horizontal flap flap flap flap flap 5 Domestic Air Condition ...
Страница 56: ...Removal of procedure 4 Removal of Drain pan 6 Domestic Air Condition ...
Страница 57: ...Removal of procedure 5 Removal of vertical blades and swing motor 7 Domestic Air Condition ...
Страница 58: ...Removal of procedure 6 Removal of Electrical Box 8 Domestic Air Condition ...
Страница 59: ...Removal of procedure 7 Removal of Heat Exchanger 9 Domestic Air Condition ...
Страница 60: ...Removal of procedure 10 Domestic Air Condition ...
Страница 61: ...Removal of procedure 8 Removal of Fan Rotor and Motor 11 Domestic Air Condition ...
Страница 62: ...Removal of procedure 12 Domestic Air Condition ...