Specifications
Domestic air conditioner
TECHNICAL SPECIFICATIONS-PARTS
cooling
heating
Fan
Type
Cross flow fan
Motor output
W 40 40
Air flow rate(high)
m³/h 650 650
Speed(super/high/low) rpm
1050/900/750 1000/850/700
Heat exchanger
Type
ML fin-
¶
7HI-HX tube
Segment *stage*fitch
3*14*1.4
Air direction control
Right,Left,Horizontal,Downward
Air filter
Removable/Washable/Mildew Proof
Temperature control
Microcomputer Control
Remote controller model
YR-HB01
Note: the data are based on the conditions shown in the table below
cooling heating
Piping
length
Indoor: 27 DB/19 WB
ć
ć
Outdoor: 35 DB/24 WB
ć
ć
Indoor:20 DB
ć
Outdoor: 7 DB/6 WB
ć
ć
5m
4
ˊ
Sensors list
type
Description
Qty
Room sensor
Its used for detecting room temperature
1
Pipe sensor
Its used for detecting temperature of evaporator
1
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3
9
Содержание N-Series
Страница 47: ...Circuit diagrams Domestic air conditioner 12 Circuit diagrams 45 ...
Страница 48: ...Circuit diagrams Domestic air conditioner 46 ...
Страница 51: ...Removal of procedure 1 Removal of Air Filter 1 Domestic Air Condition ...
Страница 54: ...Removal of procedure three two HOOKS 4 Domestic Air Condition ...
Страница 55: ...Removal of procedure 3 Removal of horizontal flap flap flap flap flap 5 Domestic Air Condition ...
Страница 56: ...Removal of procedure 4 Removal of Drain pan 6 Domestic Air Condition ...
Страница 57: ...Removal of procedure 5 Removal of vertical blades and swing motor 7 Domestic Air Condition ...
Страница 58: ...Removal of procedure 6 Removal of Electrical Box 8 Domestic Air Condition ...
Страница 59: ...Removal of procedure 7 Removal of Heat Exchanger 9 Domestic Air Condition ...
Страница 60: ...Removal of procedure 10 Domestic Air Condition ...
Страница 61: ...Removal of procedure 8 Removal of Fan Rotor and Motor 11 Domestic Air Condition ...
Страница 62: ...Removal of procedure 12 Domestic Air Condition ...