background image

序号/

No.

0
1
2

时间/

Time

20130425
20130425
20130425

设定温度/

Setting Temp.

5
5
5

箱内温度/

Inner Temp.

5.6

5

4.9

...

...

...

...

Press the “Cal” for 10s and the display area of inner temperature shows “1P” stably. Press the “Cal ”, 
and the display area of inner temperature blinks the year. Press the “Sensor ” (decrease) or 
“Cal Cancel” (increase) to choose the year. It displays 10 to 99 recurrently. For example, to set 2013,
choose 13 and press the “Cal ” to save it. And then the display area of inner temperature shows "2P" 
stably. Press the “Cal”, and the display area of inner temperature blinks the month . Press the 
“Sensor ” (decrease) or “Cal Cancel” (increase) to choose the month. It displays 01 to 12 recurrently.
When the current month comes out, press the “Cal ” to save it. And then the display area of inner 
temperature shows “3P” stably. Press the “Cal ”, and the display area of inner temperature blinks 
the date . Press the“Sensor ” (decrease) or “Cal Cancel” (increase) to choose the date. It displays 
01 to 31 recurrently. When the current local date comes out, press the “Cal ” to save it. After that, 
the display area of inner temperature shows “4P” stably. Press the “Cal ”, and the display area of 
inner temperature blinks the hour.Press the “Sensor ” (decrease) or “Cal Cancel” (increase) to 
choose the hour. It displays 00 to 23 recurrently. When the current local hour comes out, press the
 “ Cal ” to save it. After that, the display area of inner temperature shows “5P” stably. Press the 
“ Cal ”, and the display area of inner temperature blinks the minute. Press the “Sensor ”(decrease)
or “Cal Cancel” (increase) to choose the minute. It displays 00 to 59 recurrently. When the current 
local minute comes out, press the “Cal ” to save it. After that, the display area of inner temperature 

USB Function

The computer has a USB function.  Test data can be exported via the USB port. The computer can 
automatically collect and store the test data within the recent 10 years. It collects data every other 6 
minutes and stores them automatically. The latest data will automatically replace the earliest data 
when the data storage is full.With a USB port plugged in, the computer will automatically identify it 
and start to export data to the USB port.In the data exporting process, if you press “ Cal ” , the 
screen will blink “ USb” , which indicates the data are now exporting and not finished yet. After 
blinking 5s, it exits and displays the actual temperature in the case.If the displays “ ALL”  stably, the 
data export is finished. It exits 5s later can displays the actual temperature in the case.The USB port 
can be removed at this point. The exported data are in the following formats:

Functions of USB interface

Time setting of USB interface data recording (time system current setting):

26

19

HYC-940F

Control panel

Light switch

Door lock

Door ajar alarm switch

Handle

Caster

Leveling leg

Содержание HYC-260

Страница 1: ...ersion 1st 2017 Dedicated code 0270501031 V13026 Read the Operation Manual carefully before using your appliance Keep the Operation Manual in a safe place Appearance color and layout of the door may vary Translation of the original instruction This product is only applicable for storage of pharmaceutical products or drugs Not applicable for storage of blood or blood products including biological p...

Страница 2: ...0 HYC 290 HYC 390 HYC 390F HYC 610 HYC 890 HYC 940 HYC 940F Haier Type Designation Trademark Packing List Plastic bag Key Shelves Label strip Drain hole cap Fixed card Model Operation Manual HYC 360 HYC 260 HYC 290 1 2 4 4 1 16 1 1 2 5 5 1 20 1 1 2 5 5 1 1 Brackets for rear wall distance 2 2 HYC 390 1 2 7 7 1 1 2 Pad lock Handle Kits Power cord Kits 1 0 1 0 1 1 2 HYC 390F 1 2 7 7 1 1 2 1 1 1 Plast...

Страница 3: ...echnologies except HYC 260 360 Automatic removal of condensate water Note Technical information might be somewhat different on your refrigerator than published due to continuous improvement The product is applicable to pharmacies pharmaceutical factories quarantine stations health centers and hospitals used to store pharmaceuticals medicine and other related products which need a storage environme...

Страница 4: ...gh low temperature alarm sensor error alarm power failure alarm low battery power alarm door ajar alarm DC 12V rechargeable battery Name Model 48 h when the battery is fully charged Anti shock Safety Classification I Power connection type Y Climate Type 4 Foaming Agent CP IP Noise Level Lp 45dB A 770W 4 5A 115V 60Hz 850W 11A 1130 755 1980 1030 590 1425 Note Climate Type 4 means the temperature is ...

Страница 5: ... the unit over to cause personal injury Only connect the refrigerator unit with a dedicated power outlet specified by the nameplate of the unit This is to avoid fire or electric shock If the supply voltage is lower than 198 V or higher than 242 V an automatic voltage regulator of at least 4 000 W should be installed with the refrigerator Safety Precautions Ignoring this warning may result in death...

Страница 6: ...supervision is unavailable for a long time make sure children are not near the unit and the door cannot be completely closed and locked End of life disposal of a unit should only be performed by a professional Remove the door to avoid accidents such as suffocation Do not store flammable explosive or volatile articles inside the refrigerator and do not use flammable sprays nearby This is to avoid a...

Страница 7: ...e built in structure clear of obstruction If your cabinet is to be discard you must remove the door and leave the shelves in place This will reduce the posibility of danger to children And the flammable foaming needs to be disposed by professional persons CP IP foaming materials are flammable need professional processing HYC 390 665 710 1965 530 555 1380 390L 7 R134a 305g LED 3W 116kg 2 8 220 240V...

Страница 8: ...n in a short time The refrigerator is designed to operate at a condition of 16 to 32 and humidity less than 85 RH for HYC 260 360 the humidity should be less than 70 RH Small amount of condensation can occur on the surface of the unit if the actual condition is outside of this range The storage temperature of the unit however is not impacted To reduce the condensation please improve the ventilatio...

Страница 9: ...o ensure the supply voltage is within 10 of the rated voltage supply The refrigerator must be grounded reliably Check the integrity of the socket ground before power up If it is not grounded appropriately repair the wiring before installing the unit Do not ground the refrigerator through gas lines water lines telephone lines or lighting rods as these devices may cause electric shock and danger Pro...

Страница 10: ...hould be used to remove the unit off the pallet Forklift should reach the bottom of the wood pallet for lifting The unit should not be tilted at an angle of more than 45 degree Circuit diagram HYC 890 CN2 Compressor Defrosting heating strip CN2 CN1 CN3 CN11 BT1 BAT BAT Main control panel CN5 Display panel CN2 CN3 Sensor Alarm Defrosting Control Lower temperature Upper temperature VCC GND Heating s...

Страница 11: ...he shelf is placed firmly See Pic 1 see Pic 2 for HYC 610 HYC 890 Pic 1 Pic 2 9 Circuit diagram HYC 610 CN2 Cooling fan Compressor Defrosting heating strip CN2 CN1 CN3 CN11 BT1 BAT BAT Main control panel CN5 Internal fan Display panel CN2 CN3 Sensor Alarm Defrosting Control Lower temperature Upper temperature VCC GND Heating strip at the cabinet outlet CN1 t Door heating strip Door heating transfo...

Страница 12: ...he mechanical thermostat can be exchanged CN6 NO COM NC NO COM NC Remote alarm port Compressor Note The content in the frame with dotted lines are applicable for products with the printer LED lamp bank Printer door Door switch Note HYC 390F has no Door heating strip Door heating transformer and mechanical thermostat 8 Back Bracket HYC 260 360 290 390 390F Pic 5 9 Power line bracket installation HY...

Страница 13: ... stable condition When the temperature becomes stable inspect the actual temperature to make sure it matches the set point Turn on the light switch and ensure the light inside the freezer operates properly When the refrigerator passes all the functional inspections load in products in batches Initial Power on 11 Circuit Diagram Circuit diagram HYC 260 360 CN2 CN2 CN1 CN6 NO COM NC CN3 CN11 BT1 BAT...

Страница 14: ...ot be closed completely Do not place any article in the space between liner bottom and underbed shelf of the refrigerator to avoid blocking of air duct which may affect homogeneity of temperature inside Operation after Power Outage 12 The refrigerator does not work Fault Troubleshooting The refrigeration effect is weak and temperature exceeds upper limit Unit seems to emit too much noise Alarm lig...

Страница 15: ... replacement b Battery removal 1 Unplug the unit from the power outlet 2 Remove the screws on the cover with a screw driver 3 Unplug the battery s connecting plugs 4 Remove the battery s holding clip and remove the battery 5 Recycle or dispose of the used battery as required When replacing the battery make sure that brown wire is connected to the battery s positive pole and blue wire to the batter...

Страница 16: ...nth to keep the appearance new and reduce the chance for gem formation Use a damp cloth to clean off dust on the refrigerator If necessary use light detergent water to wipe off the unit if necessary Then use a dry cloth to wipe it again Do not dump water directly onto the interior of the unit to avoid damage to electrical systems Compressor and other mechanical parts are hermetically sealed They d...

Страница 17: ... alarm terminals are installed on the refrigerator and the alarm signal behind the compartment is output by the terminals The bearing capacity of the terminals is DC 30V 2A Terminal output Remote alarm terminals include NO NC and COM The user can choose NO or NC if needed Remote Alarm Terminals HYC 290 390 390F 610 890 940 940F has remote alarm terminals HYC 260 360 series does not have the remote...

Страница 18: ...en repeat Alarm light flashes after 10 min delay Impulsive sound alarm Impulsive sound alarm within 48h outage Give impulsive sound alarm after 10 min delay If upper temperature sensor or lower temperature sensor perceives temperature of the refrigerator 8 Outage of the refrigerator Outer door ajar or open Open circuit or short circuit of the upper temperature sensor If upper temperature sensor or...

Страница 19: ... all changes of parameters will not become effective The previous settings are restored 2 If the unit is powered off before the parameters are saved the control parameters in the RAM will be lost The unit will retain the previous set up once the power recovers 3 Humidity measuring range 20 90 RH humidity measurement accuracy 5 RH 40 RH 80 RH 8 RH Others ...

Страница 20: ...rameter if other parameters do not need to set press the Cal for 5s to save it and exit Please checking the time before use if the time is not right follow the upper method to adjust the time HYC 940 Control panel Handle Light switch Shelf Glass door Door lock Leveling leg Caster Anti condensation controller HYC 890 Anti condensation controller intelligently operates the heating on the door and ca...

Страница 21: ... hour comes out press the Cal to save it After that the display area of inner temperature shows 5P stably Press the Cal and the display area of inner temperature blinks the minute Press the Sensor decrease or Cal Cancel increase to choose the minute It displays 00 to 59 recurrently When the current local minute comes out press the Cal to save it After that the display area of inner temperature USB...

Страница 22: ...n for at least 2 additional hours after it reaches stable condition 2 Place a standard thermocouple in the temperature solution bottle filled with 100 ml 10 glycerol solution Place the sensor of the temperature recorder into the sensor bottle as well 3 Place the sensor bottle in the refrigerator for at least 4 hours Compare the thermocouple reading and the recorder reading If there is a discrepanc...

Страница 23: ...ding pen to make the nib contact with the recording paper Note Do not damage the nib and crossbeam If it is difficult to be adjusted use a screwdriver to dismount the crossbeam After bending the crossbeam with a little strength install back the crossbeam and repeat the above operations 6 Ensure the accuracy of the recorder Calibrate the preciseness of the recording pen after each replacement of pa...

Страница 24: ...r surface The equipment will start the forced defrost cycle Once the frost is thawed the refrigerator will resume normal operation Chart Adjustment Buttons 9 volt battery Chart Adjustment Buttons Imprinting Stylus Date Reference Mark Center Nut and Chain Chart Paper Temperature Recorder optional Chamber temperature recorder with 6 inch standard panel is optional for HYC 610 to record chamber tempe...

Отзывы: