
40
Always check the settings in the controller after restarting a unit from a power outage or
shut off. Change of settings may cause damage to the products stored.
If the power is shut off, let the unit sit for 5 minutes before it is powered up again to avoid
damaging the compressor or the system.
Wear gloves when performing maintenance to prevent personal injury as a result of sharp
edges or corners.
Hold the knob when closing the door to prevent finger pinching.
The angle of inclination shall not be greater than 45°when handling the refrigerator.
Be aware of the danger of tripping when working with the refrigerator to avoid managing
the unit or personal injury.
Do not use the door knob to prevent refrigerator damage or personal injury.
Do not use electrical appliances inside the food storage compartments of the appliance,
unless they are of the type recommended by the manufacturer.
Do not damage the refrigeration line.
Position the refrigerator to make sure the power plug is accessible.
The appliance must be placed on a solid and flat surface, or excessive vibration and
noise may be produced when the appliance in operation.
The appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capacibilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
If the power supply cord is damaged, it should be replaced by a qualified technician to
avoid a hazard condition.
Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of
obstruction.
If your cabinet is to be discard, you must remove the door and leave the shelves in
place. This will reduce the posibility of danger to children. And the flammable foaming
needs to be disposed by professional persons.
CP/IP foaming materials are flammable, need professional processing.
HYC-390
665×710×1965
530×555×1380
390L
7
R134a 305g
LED 3W
116kg
2
℃
~8
℃
220-240V~/50/60Hz
380W/2.4A
HYC-290
665×710×1665
530×555×1080
290L
5
Fin tube type / Plate type
Microprocessor controlled
R134a 300g
LED 3W
105kg
2
℃
~8
℃
220-240V~/50/60Hz
340W/2.2A
Glass door with electric heat
Force-air cooling circulation
Cold-rolled steel sheet with powder coated /HIPS plate
Pharmaceutical Refrigerator
Effective Volume
Door
Compressor
Shelves
Refrigerating Method
Refrigerant
Net Weight
Rated Power/Current
Rechargeable Battery
High & low temperature alarm, sensor error alarm, power failure alarm,
low battery power alarm, door ajar alarm
DC 12V rechargeable battery
Name
Model
48 h (when the battery is fully charged)
Anti-shock Safety
Classification
I
I
Power connection type
Y
Y
Climate Type
4
4
Foaming Agent
CP/IP
CP/IP
Noise Level(Lp)
43dB(A)
43dB(A)
Note: Climate Type 4 means the temperature is +30
℃
,the relative humidity is 55%.Technical information may vary from
the appliance that you have just purchased due to technical improvements.
665×710×1965
530×555×1380
390L
Solid Door
R134a 305g
106kg
220-240V~/50/60Hz
300W/2.4A
I
Y
7
LED 3W
2
℃
~8
℃
4
CP/IP
43dB(A)
HYC-390F
115V~/60Hz
115V~/60Hz
460W/5.0A
R404a 250g
R404a 300g
500W/5.5A
≤26kg per shelf
≤26kg per shelf
≤26kg per shelf
47dB(A)
47dB(A)
Exterior Dimensions
(W×D×H) (mm)
Interior Dimensions
(W×D×H) (mm)
Exterior / Interior
Insulation
Load
Condenser/Evaporater
Interior light
Temperature Control
Temperature Range of
sensor in glycerin bottle
Voltage
Alarm system
Battery duration
for alarm system
CFC-Free foamed-in-place urethane
High Quality Hermetically sealed compressor
5
Specification