Do not ground the refrigerator through gas pipes, water supply pipes, telephone lines or lighting 
conductors. These types of connections can cause electric shock.

Do not touch electric parts such as power plugs or switches with wet hands to prevent electric 
shock.

When pulling  the plug out  of the  power  socket, hold the power  plug instead  of  power  cable. 
Pulling the cable can cause a damage and personal injury.

Unplug the refrigerator unit if it malfunctions to avoid fi re or personal injury.

Dismantling, repairing and retrofi tting a unit should only be performed by a professional to avoid 
personal injury.

Disconnect the refrigerator when  repairs or maintenance are performed on the  refrigerator to 
prevent electric shock or personal injuries.

Do not inhale airborne particles inside and near the refrigerator during routine maintenance. This 
is to avoid health hazard.

To avoid any potential danger to human health or environment, the refrigerator should be used in 
safe regions to store toxic, harmful or radioactive particles.

If  the  refrigerator  is  to  be  decommissioned,  unplug  the  power  cord  to  avoid  electric  shock, 
current leakage, or fi re caused by aged power lines.

If the refrigerator is left unused in area where supervision is unavailable for a long time, make 
sure children are not near the unit and the door cannot be completely closed and locked.

Do  not  store  flammable,  explosive  or  volatile  articles  inside  the  refrigerator  and  do  not  use 
fl ammable sprays nearby. This is to avoid an explosion or a fi re.

Do  not  store  corrosive  articles  such  acid  or  alkali  in  the  refrigerator. These  chemicals  can 
damage internal components or electrical parts.

Do not place packaging plastic bags within the reach of children to prevent suff ocation accidents.

Do not climb to the top of the refrigerator or place plastic bags on top of the refrigerator. This is 
to prevent tip over of the refrigerator, which can cause personnel injury.

Do not use any metal objects such as iron nails or wires into holes, gaps or vents for internal air 
circulation. This is to prevent personal injury due to contact of articles behind the holes.

Always check the settings in the controller after restarting a unit from a power outage or shut off . 
Change of settings may cause damage to the products stored.

If  the  power  is shut  off, let  the  unit  sit  for  5  minutes  before  it  is  powered  up  again  to  avoid 
damaging the compressor or the system.

Wear gloves when performing maintenance to prevent personal injury as a result of sharp edges 
or corners.

Hold the knob when closing the door to prevent fi nger pinching.

Caution

Содержание HXC-106

Страница 1: ......

Страница 2: ...guidelines 5 Product Feature 6 Product Installation 7 Component Names Control Panel 12 Application method 16 Display and alarm 22 Cleaning and Maintenance 26 FAQ 28 Refrigeration Schematic Circuit Di...

Страница 3: ...en replacing the light from the power source to avoid electric hazards Warning 1 Unauthorized opening of the top cover of the control cabinet is prohibited to avoid damages to the parts inside or inju...

Страница 4: ...it is equipped with a 16A or 13A power plug Do not remove the ground pin of the power plug under any circumstances Make sure the plug is securely plugged into the power outlet to prevent re The power...

Страница 5: ...harmful or radioactive particles If the refrigerator is to be decommissioned unplug the power cord to avoid electric shock current leakage or re caused by aged power lines If the refrigerator is left...

Страница 6: ...accelerate the defrosting process other than those recommended by the manufacturer Do not damage the refrigerant circuit In order to reduce ammability HAZARDS the installation of this equipment shall...

Страница 7: ...e as the temperature in the center of the refrigerator The cabinet temperature will gradually reach an equilibrium state Only clean the unit with light soapy water Never use brushes acids gasoline soa...

Страница 8: ...lood bank refrigerator provided to you may be a little di erent from the gure in the manual due to product improvement The manual may be subject to changes without further notice 35 Name Blood Bank Re...

Страница 9: ...frigerator Do not install the refrigerator in a narrow and con ned space as heat may be trapped to increase ambient temperature Additionally a unit should not be installed in a space where the entry d...

Страница 10: ...14 1055 Interior dimensions W x D x H mm 460 370 950 430 350 830 E ective volume 158L 106L Door Glass door with electric heat Insulation CFC Free foamed in place urethane Compressor High Quality Herme...

Страница 11: ...mal operation 6 Installation of the Handle Handle installation of products shall be conducted in the following steps Orient the handle with the hole downwards Align the handle and handle guide on door...

Страница 12: ...ce the unit is powered up the audible alarm is turned on Turn on the battery switch and press the buzz cancel button to silence the alarm Visual alarm continues until the temperature in the measuremen...

Страница 13: ...oducts Do not load in too much warm product at one time Overloading the refrigerator will reduce the system s expected life Therefore product and samples should be placed into the refrigerator in batc...

Страница 14: ...g Temperature recorder Optional for HXC 158 Blood storage basket or drawer Shelf USB port optional Interior light Temperature measurement box Caster Door ajar alarm switch Air filter grille 29 Refrige...

Страница 15: ...perature is too high Air duct is blocked Unit seems to emit too much noise Check the installation of the unit to make sure the unit does sit on a solid oor without vibration Whether certain part of th...

Страница 16: ...temperature recorder is standard on the product optional for HXC 158 If additional chart paper is needed please contact Haier Biomedical The ordering cycle is 1 2 months Consult us by phone for detail...

Страница 17: ...e after sales service personnel Cleaning and Maintenance Warning Clean the refrigerator Replace the illumination light Condensate evaporator is located in the back of the refrigerator Remove the 2 scr...

Страница 18: ...tem is in a n alarm mode press the Buzzer Cancel key on the display board and the audible alarm is silenced temporarily Remote alarm condition will not be a ected After 30 minutes if the alarm conditi...

Страница 19: ...timely manner to protect the samples When there is a fault in the battery E5 will show after pressing Alarm test Check the battery charge switch to make sure it is in the On position If it is O turn...

Страница 20: ...ly Buzzing Alarm light ashes Display actual temperature Remote alarm contacts reverse and audible alarm starts Remote alarm can be cancelled after pressing Silence button If the alarm condition persis...

Страница 21: ...y battery is low ashing of LED indicator lamp on the recorder indicates that the battery needs to be changed Maintenance and change of emergency battery of the recorder When the green LED of recorder...

Страница 22: ...lay panel ashes USB which indicates the data are now exporting and not nished yet After 5 seconds the display will return to the temperature mode If the display shows ALL indicating the data export pr...