Haier HXC-106 Скачать руководство пользователя страница 4

2

Actions or operations 
which are prohibited

Actions or operations 
which must be followed

Under all conditions marked with

, It is 

necessary to consult the documentation to 
undesratnd , the potential risks and know any 
countermeasures that must be taken.

Ignoring this warning may result in deatn or 
serious injury

Ignoring this warning may result in deatn 
or serious injury,and/or damage to the 
refrigerator and property

When  there  is  a  leak  of  flammable  gas,  turn  off  the  gas  supply  valve.  Open  windows  for 
ventilation and exhaust. Do not plug in your refrigerator or unplug your refrigerator as spark in 
these processes can cause an explosion or fi re.
We recommend the unit be installed by a professional to avoid any electrical hazard.
Place the refrigerator on solid and fl at ground to avoid tipping the unit over to cause personal 
injury.
Only connect the refrigerator unit with a dedicated power outlet specifi ed by the nameplate of the 
unit. This is to avoid fi re or electric shock.
If the supply voltage is out of rated voltge ±10%, an automatic voltage regulator of at least 4,000 
W should be installed with the refrigerator.
If the power cord needs to be lengthen, the cross section area of the extension line’s conductor 
should be at least 2 mm² and the length of the extension cord should be limited to 3 m. This is to 
prevent electric fi re or shock.
The power cord of the unit is equipped with a 16A or 13A power plug. Do not remove the ground 
pin of the power plug under any circumstances. Make sure the plug is securely plugged into the 
power outlet to prevent fi re.
The power socket must be equipped with a ground wire to prevent electric shock. If the socket 
fails to be grounded, the ground wire must be installed before the refrigerator is plugged in.
Do  not  use  the  refrigerator  outdoors.  Such  installation  may  result  in  electric  leakage  if  the 
refrigerator gets wet by rainwater.
Do not place the refrigerator in humid places or places where the unit may get splashed on by 
water. This is to avoid electric shock due to deterioration of insulation.
When this is a fi re, do not pour water onto the refrigerator unit as a means to prevent electric 
shock or short circuit.
Do not place containers of water or heavy objects on the refrigerator. Falling objects may cause 
personal injury and overfl own water may damage the insulation to cause electric shock and fi re.

Safety precautions

39

Global Warning Potential

Model

Rated voltage(VAC)

Rated frequency(Hz)

CO

2

 

equivalent(Tonnes)

HXC-106

220-240V~

50/60

0.001

HXC-158

220-240V~

50/60

0.002

HXC-158B

220-240V~

50/60

0.002

HXC-358

220-240V~

50/60

0.601

HXC-358B

220-240V~

50/60

0.601

HXC-608

220-240V~

50/60

0.601

HXC-608

115V

50

0.601

HXC-608B

220-240V~

50/60

0.601

HXC-1308

220-240V~

50/60

0.701

HXC-1308B

220-240V~

50/60

0.701

This product contains fl uorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into 
the atmosphere.

GWP=global warning potential

Refrigerant type

GWP

R134a

1430

R600a

20

Содержание HXC-106

Страница 1: ......

Страница 2: ...guidelines 5 Product Feature 6 Product Installation 7 Component Names Control Panel 12 Application method 16 Display and alarm 22 Cleaning and Maintenance 26 FAQ 28 Refrigeration Schematic Circuit Di...

Страница 3: ...en replacing the light from the power source to avoid electric hazards Warning 1 Unauthorized opening of the top cover of the control cabinet is prohibited to avoid damages to the parts inside or inju...

Страница 4: ...it is equipped with a 16A or 13A power plug Do not remove the ground pin of the power plug under any circumstances Make sure the plug is securely plugged into the power outlet to prevent re The power...

Страница 5: ...harmful or radioactive particles If the refrigerator is to be decommissioned unplug the power cord to avoid electric shock current leakage or re caused by aged power lines If the refrigerator is left...

Страница 6: ...accelerate the defrosting process other than those recommended by the manufacturer Do not damage the refrigerant circuit In order to reduce ammability HAZARDS the installation of this equipment shall...

Страница 7: ...e as the temperature in the center of the refrigerator The cabinet temperature will gradually reach an equilibrium state Only clean the unit with light soapy water Never use brushes acids gasoline soa...

Страница 8: ...lood bank refrigerator provided to you may be a little di erent from the gure in the manual due to product improvement The manual may be subject to changes without further notice 35 Name Blood Bank Re...

Страница 9: ...frigerator Do not install the refrigerator in a narrow and con ned space as heat may be trapped to increase ambient temperature Additionally a unit should not be installed in a space where the entry d...

Страница 10: ...14 1055 Interior dimensions W x D x H mm 460 370 950 430 350 830 E ective volume 158L 106L Door Glass door with electric heat Insulation CFC Free foamed in place urethane Compressor High Quality Herme...

Страница 11: ...mal operation 6 Installation of the Handle Handle installation of products shall be conducted in the following steps Orient the handle with the hole downwards Align the handle and handle guide on door...

Страница 12: ...ce the unit is powered up the audible alarm is turned on Turn on the battery switch and press the buzz cancel button to silence the alarm Visual alarm continues until the temperature in the measuremen...

Страница 13: ...oducts Do not load in too much warm product at one time Overloading the refrigerator will reduce the system s expected life Therefore product and samples should be placed into the refrigerator in batc...

Страница 14: ...g Temperature recorder Optional for HXC 158 Blood storage basket or drawer Shelf USB port optional Interior light Temperature measurement box Caster Door ajar alarm switch Air filter grille 29 Refrige...

Страница 15: ...perature is too high Air duct is blocked Unit seems to emit too much noise Check the installation of the unit to make sure the unit does sit on a solid oor without vibration Whether certain part of th...

Страница 16: ...temperature recorder is standard on the product optional for HXC 158 If additional chart paper is needed please contact Haier Biomedical The ordering cycle is 1 2 months Consult us by phone for detail...

Страница 17: ...e after sales service personnel Cleaning and Maintenance Warning Clean the refrigerator Replace the illumination light Condensate evaporator is located in the back of the refrigerator Remove the 2 scr...

Страница 18: ...tem is in a n alarm mode press the Buzzer Cancel key on the display board and the audible alarm is silenced temporarily Remote alarm condition will not be a ected After 30 minutes if the alarm conditi...

Страница 19: ...timely manner to protect the samples When there is a fault in the battery E5 will show after pressing Alarm test Check the battery charge switch to make sure it is in the On position If it is O turn...

Страница 20: ...ly Buzzing Alarm light ashes Display actual temperature Remote alarm contacts reverse and audible alarm starts Remote alarm can be cancelled after pressing Silence button If the alarm condition persis...

Страница 21: ...y battery is low ashing of LED indicator lamp on the recorder indicates that the battery needs to be changed Maintenance and change of emergency battery of the recorder When the green LED of recorder...

Страница 22: ...lay panel ashes USB which indicates the data are now exporting and not nished yet After 5 seconds the display will return to the temperature mode If the display shows ALL indicating the data export pr...

Отзывы: