3
HSU-09LEK03
(DB)
HSU-12LEK03
(DB)
Indoor unit
Outdoor unit
HSU-108CH09
HSU-138CH09
Power cable:
3G1.0mm
Indoor unit
Outdoor unit
HSU-09LEK03
Indoor unit
Outdoor unit
HSU-12LEK03
HSU-07HEK03
HSU-12HEK03
HSU-09LEK13
HSU-12LEK13
HSU-07LEK03
HSU-09HEK03
HSU-12LEK13-M
)
2(
N
)
1(
L
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
Remove terminal cover at right bottom corner of indoor unit, then
take off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which
the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable making a loop.
Indoor unit
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
is not correct, proper operation can not be carried out and will cause defect.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the
distance between its two contacts should be not less than 3mm.
If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.
Power cable:
3G2.5mm
4G0.75mm
Indoor unit
Outdoor unit
HSU-24LEK13
HSU-24LEK03-Y2
HSU-18LEK13
HSU-18HEK03
1
/
POWER
SUPPLY
BL
BR
Y/G
Indoor unit
Outdoor uni
t
6G0.75mm
Power cable:
3G2.5mm
HSU-24HEK03
Power cable:
3G1.5mm
HSU-18LEK03/(DB)
Indoor unit
Outdoor unit
{
POWER
4G0.75mm
2
HSU-18LK2S3
HSU-12LEK03-Y3
HSU-18LEK03-Y3
HSU-09CK2S3
HSU-09LEK03-Y3
HSU-12CK2S3
HSU-09LB11T
HSU-09LD11T
HSU-12LB11T
HSU-12LD11T
HSU-18LD11T
HSU-18LB11T
HSU-24LD11T
3G1.0mm
Power cable:
HSU-24
LK2S3
HSU-05LEK03-Y
HSU-07LEK03-Y
HSU-09LEK03-Y
HSU-12LEK03-Y
HSU-18LEK03-Y
HSU-09LB11
HSU-09LD11
HSU-22LB11
HSU-22LD11
HSU-12LB11
HSU-12LD11
HSU-18LB11
HSU-18LD11
HSU-24LEK03-Y3
HSU-09LEK03-Y2
HSU-12LEK03-Y2
HSU-18LEK03-Y2
HSU-18LEK03
HSU-09CK2W3
HSU-09CK6B3
HSU-12CK2W3
HSU-12CK6B3
HSU-18LK2W3
HSU-18LK6B3
SAS-09HEK3
SAS-12HEK3
SAS-18HEK3
SAS-24HEK3
HSU-12LEK03-Y5
HSU-09LEK03-Y5
HSU-12LH03
HSU-09LH03
HSU-18LEK03-Y5
HSU-18LH03
HSU-24LEK03-Y5
HSU-24LH03
Power cable:
3G2.5mm
Indoor unit
Outdoor unit
1
/
POWER
SUPPLY
BL
BR
Y/G
4G0.75mm
HSU-18HH03
HSU-18HEG03
HSU-24HH03
HSU-24HEG03
HSU-12HH03
HSU-09HH03
HSU-12HEG03
HSU-09HEG03
HSU-18LEK03-Y6
HSU-12LEK03-Y6
3G1.0mm
-mod 09-12:
2
3G1.5mm
-mod 18:
2
Outdoor unit
Power cable:
3G2.5mm
4G0.75mm
&
/
1
1
/
POWER
N
L
Indoor unit