Selection of pipe
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
2
Liquid pipe (
)
For 07 09 108
6.35mm(1/4")
Gas pipe ( )
9.52mm(3/8")
For 12 18 138
12.7mm(1/2")
HSU-09HEK03
HSU-09LEK03
HSU-12HEK03
HSU-12LEK03
6.35mm(1/4")
HSU-09LEK13
HSU-12LEK13
HSU-07LEK03
HSU-07HEK03
1.Fitting of the Mounting Plate and Positioning of the wall Hole
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
Make a hole of 60 mm in diameter,
slightly descending to outside the wall.
Install piping hole cover and seal it
off with putty after installation
Indoor unit
(Section of wall hole)
Piping hole pipe
Outdoor side
Thickness
of wall
Indoor side
Wall hole
60mm
G
A=145mm
B= 60mm
30mm
HSU-09LEK03/ (DB)
HSU-12LEK03/ (DB)
HSU-18LEK13
60mm
30mm
HSU-108CH09
HSU-138CH09
30mm
HSU-12LEK13-M
9K 12K
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
140
500
140
256
113.5
583
113.5
19
5.
3
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
140
140
415
280
15.88mm(5/8")
9.52mm(3/8")
For 24
HSU-24LEK13
A=145mm
B= 60mm
A=145mm
B=
HSU-18HEK03
18K
HSU-24HEK03
24K
HSU-18LEK03/ (DB)
HSU-18LK2S3
HSU-12LEK03-Y3
HSU-24LK2S3
HSU-18LEK03-Y3
HSU-24LEK03-Y2
HSU-09CK2S3
HSU-09LEK03-Y3
HSU-12CK2S3
HSU-108CH09
HSU-138CH09
HSU-09LB11T
HSU-09LD11T
HSU-12LB11T
HSU-12LD11T
HSU-18LD11T
HSU-18LB11T
HSU-24LD11T
HSU-05LEK03-Y
HSU-07LEK03-Y
HSU-09LEK03-Y
HSU-12LEK03-Y
HSU-18LEK03-Y
HSU-09LB11
HSU-09LD11
HSU-22LB11
HSU-22LD11
HSU-12LB11
HSU-12LD11
HSU-18LB11
HSU-18LD11
HSU-09LEK03-Y2
HSU-12LEK03-Y2
HSU-18LEK03-Y2
HSU-24LEK03-Y3
HSU-18LEK03
HSU-09CK2W3
HSU-09CK6B3
HSU-12CK2W3
HSU-12CK6B3
HSU-18LK2W3
HSU-18LK6B3
SAS-09HEK3
SAS-12HEK3
SAS-18HEK3
SAS-24HEK3
HSU-12LEK03-Y5
HSU-09LEK03-Y5
HSU-12LH03
HSU-09LH03
HSU-18LEK03-Y5
HSU-18LH03
HSU-24LEK03-Y5
HSU-24LH03
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-12HH03
HSU-09HH03
HSU-18HH03
HSU-24HH03
HSU-12HEG03
HSU-09HEG03
HSU-18HEG03
HSU-24HEG03
HSU-18LEK03-Y5(6)
HSU-18LH03
HSU-12LEK03-Y5(6)
HSU-12LH03
HSU-18LEK03-Y6
HSU-18HH03
HSU-18HEG03
HSU-18LEK03-Y6