Indoor unit

1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
   qualified person. The type of connecting wire is H05RN-F or H07RN-F.
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.

5

6.Easily-demount cleaning of indoor unit

1.Top inlet can be taken down

Open the inlet grille, press the claw of the clip on the unit,then
take down the top inlet.(according to figure 1)

2.Vertical flap can be taken down

Overturn the vertical flap, press the claw of the clip ,then take
down vertical flap.(according to figure 2)

3.Horizontal louvers can be taken down

After taking down vertical flap.Horizontal louvers are appeared,draw
the middle louver,and take down the horizontal louvers .
(according to figure 3)

5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance
    between its two contacts should be not less than 3mm.

claw of the clip

 Figure 1

 Figure 2

Daff

 Figure 3

BRN

WHT

BLK

RED

YEL/GRN

BRN

WHT

BLK

RED

YEL/GRN

Indoor unit

Outdoor unit

HSU-09H03/R(QXF)

HSU-12H03/R(QXF)

HSU-09H03/R(DB)

HSU-12H03/R(DB)

HSU-09C03/R(DB)

HSU-12C03/R(DB)

YEL/GRN

YEL/GRN

Indoor unit

Outdoor unit

RED

RED

BLK

BLK

WHT

WHT

Two ways for the installation of indoor part, as illustrated:
Way One : When the pipes go from the back of the indoor unit, you can connect the fresh air tube with the outlet joint
                  on the two sides of the frame,and then fix it at the pipe exit of the frame
Way Two : When installing the side outlet pipe,connect the fresh tube and the outlet joint ,and then fix it on the left side
                 or right side of the frame.Outlet pipe is connected with the pipe hole cover by the pipe lid.

5.Installation instruction on the indoor part of the fresh air device

Installation way One

Installation way Two

See the Installation from the fresh air sets for the installation of outdoor unit.

Connecting wiring:

5G1.0mm

2

+1x0.75mm

2

Connecting wiring:

3G1.5mm

2

+2x0.75mm

2

Power cable:

3G1.5mm

2

Lid for right piping

Lid for left piping

 Change-for-fresh-air tube

Drain hose

Fix with adhesive tape

Outlet joint

Fresh air tube

Outlet joint
(in guard ring)

Guard ring

To indoor unit

To outdoor fresh air motor

The connecting method of
 fresh air box signal wire

For the units with
fresh air function

Power cable:

3G1.5mm

2

Содержание HSU-09H03/R

Страница 1: ...te controller R 03 dry battery Mounting plate Drain hose Steel nail cement Screw Plastic cap Drain elbow Cover Cushion 1 1 2 3 4 5 6 7 8 9 2 1 1 6 4 1 1 4 Number of articles Accessory parts 4X50 4X25 more than 5cm more than 10cm more than 60cm more than 15cm more than 10cm more than 10cm more than 10cm Attention must be paid to the rising up of drain hose G F A Drawing for the installation of indo...

Страница 2: ...ase of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where...

Страница 3: ...ounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a hole of 66 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe Outdoor side Thickness of wall Indoor s...

Страница 4: ...e pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the connection par...

Страница 5: ...gure 3 BRN WHT BLK RED YEL GRN BRN WHT BLK RED YEL GRN Indoor unit Outdoor unit HSU 09H03 R QXF HSU 12H03 R QXF HSU 09H03 R DB HSU 12H03 R DB HSU 09C03 R DB HSU 12C03 R DB YEL GRN YEL GRN Indoor unit Outdoor unit RED RED BLK BLK WHT WHT Two ways for the installation of indoor part as illustrated Way One When the pipes go from the back of the indoor unit you can connect the fresh air tube with the ...

Страница 6: ...inal block and insert the plugs fully into terminal block then tighten the screws If wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installation of indoor and outdoor units Insert the cable according to terminal number in the same manner as the indoor unit...

Страница 7: ...s using specified torque 5 Tighten the caps on the valves with specified torque Valve rod Valve cap 7 9 20 25 Tighten torque N m When connecting pipe exceeds 5 meters 16g refrigerant shall be added per exceeding meter Charge according to the following list Piping length Additional amount 5m 7m 10m No need 32g During this procedure 50g refrigerant will be discharged in piping This must be strictly ...

Страница 8: ...n pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the instruction manual Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly inserted to ...

Отзывы: