Haier HSU-09H03/R Скачать руководство пользователя страница 8

It becomes high midway.

The end is immersed
in water.

It waves.

The gap with the ground
is too small

Less than 5cm

There is the bad smell
from a ditch

1.Power Source Installation

2.Cutting and Flaring Work of Piping

3.On Drainage

Check for Installation and Test Run

Check Items for Test Run

The power source must be exclusively used for air conditioner. (Over I0A)
In the case of installing an air conditioner in a moist place, please install an
earth leakage breaker.
For installation in other places, use a circuit breaker as far as possible.

Pipe cutting is carried out with a pipe cutter and burs must be removed.
After inserting the flare nut, flaring work is carried out.

Please install the drain hose so as to be downward slope without fail.
Please don't do the drainage as shown below.

Please pour water in the drain pan of the indoor unit, and confirm that drainage is
carried out surely to outdoor.
In case that the attached drain hose is in a room, please apply heat insulation
to it without fail.

Please kindly explain to our customers how to operate through the instruction manual.

Gas leak from pipe connecting?
Heat insulation of pipe connecting?
Are the connecting wirings of
indoor and outdoor firmly inserted
to the terminal block?
Is the connecting wiring of indoor
and outdoor firmly fixed?

Is drainage securely carried out?
Is the earth line securely
connected?
Is the indoor unit securely fixed?
Is power source voltage abided
by the code?
Is there any noise?

Put check mark       in boxes

Is the lamp normally lighting?
Are cooling and heating (when
in heat pump) performed normally?
Is the operation of room temperature
regulator normal?

8

Liquid side

Pipe diameter(    ) Size A(mm)

6.35mm(1/4")

9.52mm(3/8")

0.8~1.5

1.0~1.8

Gas side

Gas side

12.7mm(1/2")

1.2~2.0

Correct

Incorrect

Lean Damage of flare Crack

Partial

Too outside

Flare tooling die

A

Содержание HSU-09H03/R

Страница 1: ...te controller R 03 dry battery Mounting plate Drain hose Steel nail cement Screw Plastic cap Drain elbow Cover Cushion 1 1 2 3 4 5 6 7 8 9 2 1 1 6 4 1 1 4 Number of articles Accessory parts 4X50 4X25 more than 5cm more than 10cm more than 60cm more than 15cm more than 10cm more than 10cm more than 10cm Attention must be paid to the rising up of drain hose G F A Drawing for the installation of indo...

Страница 2: ...ase of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where...

Страница 3: ...ounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a hole of 66 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe Outdoor side Thickness of wall Indoor s...

Страница 4: ...e pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the connection par...

Страница 5: ...gure 3 BRN WHT BLK RED YEL GRN BRN WHT BLK RED YEL GRN Indoor unit Outdoor unit HSU 09H03 R QXF HSU 12H03 R QXF HSU 09H03 R DB HSU 12H03 R DB HSU 09C03 R DB HSU 12C03 R DB YEL GRN YEL GRN Indoor unit Outdoor unit RED RED BLK BLK WHT WHT Two ways for the installation of indoor part as illustrated Way One When the pipes go from the back of the indoor unit you can connect the fresh air tube with the ...

Страница 6: ...inal block and insert the plugs fully into terminal block then tighten the screws If wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installation of indoor and outdoor units Insert the cable according to terminal number in the same manner as the indoor unit...

Страница 7: ...s using specified torque 5 Tighten the caps on the valves with specified torque Valve rod Valve cap 7 9 20 25 Tighten torque N m When connecting pipe exceeds 5 meters 16g refrigerant shall be added per exceeding meter Charge according to the following list Piping length Additional amount 5m 7m 10m No need 32g During this procedure 50g refrigerant will be discharged in piping This must be strictly ...

Страница 8: ...n pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the instruction manual Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly inserted to ...

Отзывы: