Instructions on transportation and storage
Functionings & principles
1. During transportation or storage, the heat pump water heater shall be packed in the
undamaged package to avoid damage to appearance and performance of the product;
2. During transportation or storage, the heat pump water heater shall be in the upright
position;
The external unit shall be kept in the upright position at any time for the best
performance !
A low-pressure liquid refrigerant is vaporized in the heat pump's evaporator and passed into
the compressor. As the pressure of the refrigerant increases, so does its temperature. The
heated refrigerant runs through a condenser coil within the storage tank, transferring heat
to the water stored there. As the refrigerant delivers its heat to the water, it cools and
condenses, and then passes through an expansion valve where the pressure is reduced and
the cycle starts over.
6
English