Technical parameters
Model
(system)
HP200S1
HP300S1
Tank volume
195L
293L
Rated voltage/ frequency
230V/50Hz
230V/50Hz
Tank rated pressure
0.85MPa
0.85MPa
Corrosion protection
Magnesium rod
(x2)
Magnesium rod
(x2)
Water proof grade
IPX4
IPX4
Water inlet and outlet connection
G3/4"F
G3/4"F
Safety valve connection
G3/4"F
G3/4"F
Drain & Water intlet connection
G3/4"F
G3/4"F
Product dimension
(
tank unit
)
544*512*1765 mm
632*600*1795 mm
Packing dimension
(
tank unit
)
676*636*1927 mm
737*696*1958 mm
Packing dimension
(
external unit
)
960*425*735 mm
960*425*735 mm
Net/Gross weight
(
tank unit
)
77/89kg
98/112kg
* Tested by LCIE France according to CDC LCIE N° 103-15/B:2011 +A1:2013 and EN16147:2011.
Model (tank unit)
Dimension and connections
7
English
Product dimension
(
external unit
)
Net/Gross weight
(
external unit
)
899*352*681 mm
899*352*681 mm
41/44kg
44/48kg
Model (external unit)
TS200HE-S1
TS300HE-S1
UE1.0-S1
UE1.5-S1
Power input by electric backup
2150W
2150W
Rated power input by heat pump
665W
885W
Maximum power input by heat pump
1000W
1350W
Maximum power input
3150W
3500W
Type of extraction
Exterior
Exterior
Coefficient of performance (COP) *
3.09
3.20
Tapping cycle
L
XL
Max volume of usable hot water at 40
℃
setting at 55
℃
245.1L
382.6L
Performance certified at 7 ° C air (CDC LCIE 103-15 / B)
Standby power input/ Pes
28W
29W
Heating up time
4h03
4h45
Reference temperature /Tref
53.86
℃
53.91
℃
Assembled System
Default temperature setting
55
℃
55
℃
Temperature setting range- with heater
35
℃
-75
℃
35
℃
-75
℃
20m
20m
Max working pressure of refrigerant
0.8/2.8MPa
0.8/2.8MPa
Refrigerant type / weight
R134a/1.3kg
R134a/1.5kg
Sound power level
64dB
64dB
Ambient temperature for use of product
-7~45
℃
-7~45
℃
Operating temperature of heat pump
-7~45
℃
-7~45
℃
Maximum length of refrigerant pipe