Required Tools for Installation
• 14/4 AWG stranded wire
• 5/8” (16mm), 7/8” (22mm), 1” (25mm) or adjustable
wrench
• R-410A refrigerant*
• Adhesive tape
• Conduit cable clamp ½”*
• Copper line set (refer to indoor specification for line set
size)
• #2 phillips screwdriver
• Drill
• R-410A flaring tool
• Hex wrench
• Hole saw 2
1/4
”
• Insulation*
• Refrigerant scale
• Level
• Manifold gauge set
• Measuring tape
• Micron gauge
• Mini-split adapter (5/16”F to 1/4”M)
• Nitrogen*
• Pipe cutter
• PVC pipe (optional)
• Razor knife
• Reamer
• Saddle clamp (L.S.) w/ screws
• Sealant, non-expanding (for lineset hole)
• Soap/water solution* or gas leakage detector
• Stud finder
• Torque wrench
• Vacuum pump
• Wire strippers
• All usual and customary HVAC hand and power tools,
meters, and testing devices
* consumable
INDOOR CLEARANCES
(Appearance may vary)
This picture is for reference only. Your product may look different.
Wrap the insulation pipe with
WKH¿QLVKLQJWDSHIURPWKH
bottom to top.
Cut thermal insulation pipe to an
appropriate length and wrap it with tape,
making sure that no gap is left in the
insulation pipe’s cut line.
Arrangement of
piping directions
Condensate piping
must have a
downward slope of
at least 1/4” per foot
for proper drainage.
Rear Left
Rear Right
Right
Below
Left
More than 4 inches
clearance from ceiling
More than 4 inches
clearance from wall
(both sides)
It is recommended that the unit
LQVWDOOHGIHHWIURPWKHÀRRU
Installation Instructions