INSTALLATION REQUIREMENTS
IMPORTANT:
e
v
r
e
s
b
O
all governing codes and ordinances. Check the location where the air
conditioner will be installed. Make sure you have everything necessary for correct
installation.
THE LOCATION SHOULD PROVIDE:
•
A
grounded electrical outlet within 6 ft. (183 cm) of where the power supply cord exits the air
conditioner, for models: ESAQ406T HWQ08XCT
NOTE:
o
D not use an extension cord, plug adapter, surge protector or multi-outlet adapter.
• Free movement of air in the room to be cooled.
• A large enough window opening for the air conditioner. (See Fig.2)
• The air conditioner must not be installed in a through-the-wall sleeve or in a wall. It can only be
installed in a double-hung window.
NOTE: The outside cabinet louvers and air discharge must not be obstructed by bushes, trees,
etc. Air must be able to pass freely through the cabinet louvers. (See Fig.1)
WINDOW INSTALLATION
Window opening measurements:
ESAQ406T
HWQ08XCT
A. Width
26-1/16" - 39-1/4"
B. Height
13-3/8"
LOCATION REQUIREMENTS
WIDTH
LENGTH
WIDTH
A-WIDTH
B-HEIGHT
Fig. 2
CABINET LOUVERS
Fig. 1
AIR DISCHARGE