background image

3.  

Time setting

In active state (figures on display do not flash and On/Off indicators are off), directly press SET 
key  to  select  time  function,  then  set  time  by  pressing 

 

 

 

and 

   

.  The  setting  range  of  hour 

figure is 00~23, that of minute figure is 00~59. Press 

  

 

 

or  

   

once, then for the figure to be 

set  add  or  reduce  1.  The  figure  to  be  set  will  continuously  increase  or  decrease  under 
continuous  pressing.  Hour  figure  circulates  from  00  to  23  as  per  24H  system,  minute  figure 
changes circularly from 00 to 59. When time is set by pressing SET key, hour figure shall be 
set  firstly:  hour  figure  flashes  and  the  figure  is  set  by  pressing 

     

  or 

     

,  if  there  is  no 

operation within 6 seconds or the hour figure is confirmed by pressing SET key directly, hour 
figure  will  become  constant  lighting  state  from  flashing.  Afterwards,  minute  figure  begins 
flashing, press  

   

or 

   

 to set minute. If there is no operation within 6 seconds or the minute 

figure is confirmed by pressing SET key directly, minute figure will start constant lighting state 
from flashing, indicating the completion of temperature (

疑为时间即:

time) setting.

Note: if keys other than SET are selected when the figure flashes (within 6s), the flashing state 
setting will not work and the figure will return to the original state before setting. 
For example: in case of initial power-on startup state, the time of the heater is adjusted to be 
11:10. (As shown in Figure 7)

5

8

Usage

Current Temp.

Heating Temp.

Normal Fast

 Turbo

SPEED

SET

TIMER

Kw

.

On  Off

:

Current Temp.

Current Temp.

Heating Temp.

Heating Temp.

Normal Fast 

Turbo

Normal Fast 

Turbo

SPEED

SPEED

SET

SET

TIMER

TIMER

Kw

Kw

.

.

On  Off

On  Off

:

:

Current Temp.

Current Temp.

Current Temp.

Current Temp.

Heating Temp.

Heating Temp.

Heating Temp.

Heating Temp.

                      T urbo

                      T urbo

                      T urbo

                      Turbo

SPEED

SPEED

SPEED

SPEED

SET

SET

SET

SET

TIMER

TIMER

TIMER

TIMER

Kw

Kw

Kw

Kw

.

.

.

.

On  Off

On  Off

On  Off

On  Off

:

:

:

:

(Figure 7)

Installation must be made by installers of or designated by our company after-service 
department. The water heater shall be wall-mounted.

Make 2 holes

φ

12mm, 65mm deep in wall with an impact drill according to installation 

dimension. Insert and fix expansion hooks in corresponding wall holes. Lift the water heater. 
Make wall rack correspond to the hooks. Hang the ring of extended connection line onto a 
hook and hand the wall rack (see Figure 2). Install accessories such as safety valve as shown 
in Figure 3. Use sealing compound to prevent water leakage.

To facilitate installation and removal, it is suggested a G1/2” movable nut is fitted at 
appropriate locations on inlet and outlet pipes respectively. Find the location requiring hot 
water supply. Connect inlet pipe, outlet pipe and city water pipe respectively to the use point 
for hot water.

Note: The hot water pipe shall not be too long to reduce the heat losses.

Please reserve some space in installation for the future maintenance.

Connection and use of safety valve:
The  safety  valve  should  be  connected  to  the  water  inlet  pipe.  Please  check  carefully  if  the 
direction is correct after installation. The correct direction of installation is that the arrowhead 
on the safety valve should point to the water heater.
Please connect the drain hose to the safety valve. Connect one end of the hose to the safety 
valve vent and the other end to the sewage drain for fear of indoor contamination. The hose 
can be cut short or extended as necessary. The hose shall be installed as inclined downward.
The heater should work with the safety valve whose rated pressure is 0.80MPa. When the tap 
water pressure is no less than 0.80MPa, a large amount of water may flow out from the drain 
hose  of  the  safety  valve,  which  indicates  water  pressure  is  overly  high  and  after-service 
department shall be notified for a solution.

Installation

Installation

(Figure 2)

H

o

w

a

te

o

u

tl

e

t

Safety valve

Extended connection line

Wall rack

(Figure 6)

Expansion 

hook

(Figure 3) for installation 

reference only.

Hot water 

outlet 
valve

Cold 

water 
outlet 
valve

Mixing 

valve

Shower 

head

Cold water 

inlet

P

re

s

s

 

  

 

 k

e

y

 to

 a

d

ju

s

t t

h

e

 te

m

p

e

ra

tu

re

 in

to

 

5

5

. (

p

re

s

s

in

g

 ti

m

e

 c

a

n

 b

e

 ig

n

o

re

d

)

P

re

s

s

 S

E

T

 k

e

y

 to

 d

ire

c

tly

 c

o

n

fir

m

 o

r a

u

to

m

a

tic

a

lly

 

c

o

n

fir

m

 th

e

 ti

m

e

 if

 n

o

 o

p

e

ra

tio

n

 w

ith

in

 6

 s

e

c

o

n

d

s

.

P

re

s

s

 S

E

T

 k

e

y

th

e

n

 h

o

u

fig

u

re

 f

la

s

h

e

s

 

(p

re

s

s

in

g

 t

im

e

 c

a

n

 b

e

 ig

n

o

re

d

).

A

d

ju

s

h

o

u

fig

u

re

 t

o

 1

1

 a

n

d

 c

o

n

fir

m

 i

t, 

th

e

n

 m

in

u

te

 f

ig

u

re

 b

e

g

in

s

 f

la

s

h

in

g

.

S

im

ila

rl

y

a

d

ju

s

m

in

u

te

 

fig

u

re

 

to

 

1

0

 

a

n

d

 

c

o

n

fir

m

 it

, t

h

e

n

 t

im

e

 s

e

tt

in

g

 is

 c

o

m

p

le

te

d

.

Normal Fast

 Turbo

Normal Fast

 Turbo

Normal Fast

 Turbo

Normal Fast

 Turbo

Содержание ES15V-P1

Страница 1: ...Little Sea ox Haier Household Electric Water Heater Please read this manual before usage Retain it for future reference 0040502335 V ES15V P1 ES25V P1 ES35V P1 ...

Страница 2: ...ipeline In this case no smoke or fire is permitted near the open valve Carefully check and confirm all parts are in good condition This mark is the designation of Pre safe Expert by Haier Water Heater Company which indicates use of the company s patented technology inside the product It ensures you a safe bath while continuously monitoring whether your house ground wire is live or not If this mark...

Страница 3: ... apologize for the inconvenience occurred therefrom 12 Usage 4 Holding temperature preset Without presetting of bath state when the temperature is set to be less than 55 reheating will be started when the temperature is decreased by 5 if the temperature is set to be 55 75 including 55 and 75 reheating will be started when the temperature is decreased by 10 5 Shutdown After bath press key if you wa...

Страница 4: ...ght press SET key to preset bath and shutdown time When presetting bath time On indicator flashes when presetting shutdown time Off indicator flashes After setting if no operation is made within 2 minutes the system will enter into power saving mode and only On Off and clock on display light When up to the preset heating time calculated by the system the heater will automatically heat and the Heat...

Страница 5: ...10 Current Temp Current Temp Current Temp Current Temp Heating Temp Heating Temp Heating Temp Heating Temp Normal Turbo Fast Normal Turbo Fast Normal Fast Turbo Normal Fast Turbo SPEED SPEED SPEED SPEED SET SET SET SET TIMER TIMER TIMER TIMER Kw Kw Kw Kw On Off On Off On Off On Off Current Temp Heating Temp Normal Fast Turbo SPEED SET TIMER Kw On Off Current Temp Heating Temp Normal Turbo Fast SPE...

Страница 6: ...interface Heating Temp indicator flashes when entry into heating state from power saving mode The heater is provided with auto heating function The system automatically calculates the time required for heating to set temperature according to the heating power set by the customer and then determines the starting time for heating Before water using time set automatically heat to set temperature and ...

Страница 7: ...orresponding wall holes Lift the water heater Make wall rack correspond to the hooks Hang the ring of extended connection line onto a hook and hand the wall rack see Figure 2 Install accessories such as safety valve as shown in Figure 3 Use sealing compound to prevent water leakage To facilitate installation and removal it is suggested a G1 2 movable nut is fitted at appropriate locations on inlet...

Страница 8: ...sphere Check safety valve once a month as follows move the small handle of safety valve if there is water flowing out safety valve is normal if there is no water flow please contact local after sales service station The pressure relief hole is to be operated regularly to remove lime deposits and to verify that it is not blocked Installation Attentions in installation Installation Attentionsininsta...