background image

97

After installation is completed, the following method must be used to determine if the exhaust system is acceptable:

Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the
performance of the dryer:

The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage. The more
the dryer is used, the more often you should check the exhaust system and vent hood for proper operation.

1. Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer.
2. Set the dryer timer and temperature to air fluff (cool down) and start the dryer.
3. Read the measurement on the manometer.
4.The system back pressure MUST NOT be higher than 0.75 inches of water column. If the system back pressure is
less than 0.75 inches of water column, the system is acceptable. If the manometer reading is higher than 0.75 inches
of water column, the system is too restrictive and the installation is unacceptable.

1. Only the rigid metal duct work should be used.
2. Venting vertical through a roof may expose the exhaust system to down drafts causing an increase in vent

restriction.

3. Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint.
4. Compression or crimping of the exhaust system will cause an increase in vent restriction.

C

C

Location of your dryer

Rough-in dimensions

Do not install your dryer:

Installation in recess or closet:

In an area exposed to dripping water or outside water conditions.

The dryer installation in a bedroom, bathroom, recess or closet, must be exhausted outdoors.

In an area where it will come in contact with curtains drapes, or anything that will obstruct of combustion
and ventilation air.

Your dryer needs the space around it for proper ventilation.

On carpet, floor must be solid with a maximum slope of inch (2.54 cm).

A minimum of 120 square inches(774.2 square cm) of opening, equally divided at the top and bottom of

the door, is required. Air openings are required to be unobstructed when a door is installed. The full length of
the door is acceptable.

REAR VIEW

SIDE VIEW

DIMENSIONS

DOOR OPEN 90

28

(71.8 cm)

1/4''

50 3/5''

(128.5 cm)

Service Manual

 

 

Model No. CGDE480BW

Issue

Rev.

Содержание CGDE480BW

Страница 1: ...Electric Dryer Model No CGDE480BW Order No TL1309S001V1 2 2008 Haier Washing Machine Edition 2014 04 22 ...

Страница 2: ... 2 s t r a p f o s e m a N 4 3 s b o n k n o i t a r e p o e h t f o e g a s U 5 4 s e r u t a e f w e n d n a f e i r b s t c u d o r P 6 6 y l b m e s s a s i d d n a t n e m t s u j d a n o i t a l l a t s n i n i t n i o p y e K 7 8 Analysis of the common breakdowns 10 Service Manual Model No CGDE480BW Issue Rev ...

Страница 3: ...etting 10 min 30 min 60 min 90 min User s manual product registration card Rated voltage rated frequency Rated dry capacity Rated power consumption in drying Rated input consumption of motor Manual setting Automatic Accessories Dimension W Net eight kg 4800W 379W 1 Specification List 1 2 Dimensional Drawing 686 718 7 9 0 1 Unit mm Service Manual Model No CGDE480BW Issue Rev ...

Страница 4: ... leaf barrel roll lint filter lock body 4 Names of parts Service Manual Model No CGDE480BW Issue Rev Power line Computer Program Controller Red White White Gray Yellow Yellow Black Motor Thermal Blue Purple Orange Blue Orange Orange Relay Brown Brown Black Door Switch High Limit Thermostat Heater Control Thermostat Orange 5 4 1 6 L1 N L2 Red White Limiter Green G Gray Gray Gray Thermostat Back up ...

Страница 5: ...use Button 4 Push to shart after selecting the dry cycle and seting the temperature Push once to pause Push again to start after pushing Cycle Progress 5 This indicates the process the cycle is currently in At the end of cycyle the dryer will automatically go in the wrinkle saves mode Here the dryer tub will tumble periodically for 1 hour after the dry cycle is completed To stop simply open the do...

Страница 6: ...and exhaust system has high degree of tightness and improves the thermal efficiency 5 Heating system The electric heating thread installed on the heating plate at the rear of the cabinet is the heating source of the appliance The exchanging of cold and hot air is realized by it The heating power of the electric heating thread is about 4700W It can raise the air temperature rapidly and offer hot ai...

Страница 7: ... off Your dryer has four leveling legs which are located in the front and rear corners of your dryer After properly placing your dryer or by turning them counter clockwise to lower your dryer Leveling legs can be adjusted by turning them clockwise to raise your dryer or by turning them counter clockwise to lower your dryer 6 Lint filter It is a kind of wearing part made of filter screen frame and ...

Страница 8: ...h leveling legs located on the bottom of the dryer 1 remove all packaging material This includes the foam base and all adhensive tape holding the dryer acessories inside and outside 2 inspect and remove any remains of packing tape or printed material before using the dryer 7 Key points in installation adjustment and disassembly C C C Tools and materials required Electrical requirements Unpacking y...

Страница 9: ...rigid metal duct work should be used 2 Venting vertical through a roof may expose the exhaust system to down drafts causing an increase in vent restriction 3 Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint 4 Compression or crimping of the exhaust system will cause an increase in vent restriction C C Location of your dryer Rough in dimen...

Страница 10: ...DON T Correct Incorrect Correct DO DON T Incorrect C C Requirements and instructions Electrical connections 1 This appliance be properly grounded Electrical shock can result if the dryer is not properly grounded Follow the instructions in this manual for proper grounding MUST 3 A U L approved strain relief must be installed onto power cord If the strain relief is not attached the cord can be pulle...

Страница 11: ... nut securely so that the tension relief does not turn 9 Reinstall the terminal block cover Grounding instruction This appliances must be connected to a ground metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance nut tighten nut to these threads power cord strain relief m...

Страница 12: ... Close the door Check if the wire unit is good No No No Yes Service Manual Model No CGDE480BW Issue Rev Correctly installed Cut off the power Check if the door of the dryer is closed Check if the wire connecting of the motor and the PCB is disconnected Connect the wire properly You can replace or use ohmmeter Check if the wire connecting of the back up thermostat and the thermal limiter is ok Chec...

Страница 13: ...place the control thermostat and high limit thermostat Measure the resistance of the heater Replace the heater Broken Theresistance is infinite Well The resistance is 10 3 Yes Check the ventilation condition Check if the vent pipe and the vent way is blocked No ventilating No No Broken Yes Yes Yes Yes Check if the wire unit is good Check if the belt is broken Check if the tensive arm unit is insta...

Страница 14: ... cabinet and the cabinet or the abrasion between the support wheel and the bracket of support wheel Yes Yes Yes Yes No No No Fasten the support bracket or replace the support wheel Check the tensive condition replace the tensive spring Fasten the heating ring and the fasten screw Adjust or replace the worm shell If there is a noise from the tensive spring If there is metallic bangs because the scr...

Страница 15: ...o Yes Service Manual Model No CGDE480BW Issue Rev Cut off the power Check if the wire connecting of the door switc and PCB is disconnection Well the You can replace it or use ohmmeter resistence is 0 Broken the resistence is infinite Check if the Door switch is good Replace the door switch and make sure wire is connected properly Broken Replace the PCB Check if the PCB is good Well No Check if the...

Страница 16: ...Group Sincere Forever Haier Industrial Park No 1 Haier Road 266101 Qingdao China http www haier com ...