Functions and Control
Domestic air conditioner
7.Funcitions and Control
7.1 Main functions and control specification
7.1.1 Automatic operation
When the running mode is turned to automation after starting the system, the system will first determine
the running mode according to the current room temperature and then will run according to the determined
mode. Tr in the following selection conditions means room temperature, Ts means setting temperature, Tp
means temperature of indoor coil pipe
Tr≥Ts-3
℃
Choose Cooling Mode
Tr
<
Ts-3
℃
Choose Heating Mode
After turning to the automation mode, the running mode can be switched between cooling mode, fan
mode and heating mode according to the change of the indoor ambient temperature. But the automatic
conversion between cooling mode and heating mode must be conducted after 15 minutes.
7.1.2 Cooling operation mode
Temperature control range: 16 ---30
Temperature difference:
1
* Control features: When Tr input airflow >Ts set temperature
, the compressor will be opened, the indoor
fan will operate at the set speed and the mode signal will be sent to the outdoor system. When Tr input
airflow Ts set temperature
, the compressor will be opened, the indoor fan will operate at the set speed
and the mode signal will be sent to the outdoor system. The system will keep the original status if Tr= Ts.
Airflow speed control: (temperature difference 1 )
Automatic: When Tr Ts+3 , high speed.
When Ts+1
Tr<Ts+3 , medium speed
When Tr<Ts+1 , low speed
When the sensor is off, low speed
When the airflow speed has no delay from the high to low switching, the speed should be delayed for 3
minutes (remain at high speed for 3 minutes.) before the next switch.Manus: When the system is operating,
you can set the high, medium or low speed manually. (When the sensor is on or off, the system will change
the speed 2 seconds after receiving the signal.)*Airgate location control: the location for the airgate can be
set according to your needs.*Defrosting function: preventing the frosting on the indoor heat exchanger
(when cooling or dehumidifying). When the compressor works continuously for 6 minutes and the temperature
of the indoor coils has been below one centigrade for 10 seconds, the compressor will be stopped and the
malfunction will be recorded in the malfunction list. The indoor system will continue to run. When the temperature
of the indoor coil is raised to 9
℃
, the compressor will be restarted again (the requirement of 3 minutes’ delay
should be satisfied.)
* timing system on/off function.
* Dormant control function.
1
3
7.1.3 Dehumidifying mode.
* temperature control range: 16---30
℃
* temperature difference:
±
1
℃
Содержание AS25S2SF1FA-LW
Страница 4: ...2 5 ...
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 12: ... Piping diagrams Domestic air conditioner 5ˊPiping diagrams 10 ...
Страница 14: ...Domestic air conditioner 12 CN8 CN9 CN21 CN36 CN23 CN6 CN52 CN5 CN14 CN2 CN34 CN15 CN11 CN51 CN5 CN11 PCB ...
Страница 27: ...Seivice diagnosis Domestic air conditioner 8 Dimensional drawings 9 Center of gravity unit mm 25 ...
Страница 43: ...Circuit diagrams Domestic air conditioner 41 11 2 Circuit Diagrams ...
Страница 45: ...Removal Procedure 1 Domestic Air Conditioner Removal of front panel front panel Loosen the screw ...
Страница 46: ...Removal Procedure 2 Domestic Air Conditioner Lift up the control box cover 3 Remove the control box cover 2 ...
Страница 48: ...four 5 Removal Procedure 4 Domestic Air Conditioner 1 2 3 four Remove the casing ...
Страница 52: ...Removal Procedure 8 Domestic Air Conditioner motor cover ...
Страница 53: ...Removal Procedure 9 Domestic Air Conditioner ...