Service diagnosis
Domestic air conditioner
27
10.3 Error Codes and Description indoor display
Only For 498 and
498A display
(Red/Green Time
Run
□
On
★
●
Flash
■
Off)
Indoor and
Outdoor
E7
Directly display
■
■
★
15
Communication fault between
indoor and outdoor units
Page.36
E1
Directly display
★
■
■
/
Indoor temperature sensor failure
Page.28
E2
Directly display
★
□
□
/
Indoor coil sensor failure
Page.28
E4
Directly display
★
□
★
/
Indoor eeprom failure
Page.29
E14
Directly display
■
●
□
★
/
Indoor fan failure
Page.30
E5
Trouble record
□
■
★
22
Internal unit antifreeze
protection
/
E9
Trouble record
□
■
●
★
21
Internal unit overload
Page.39
F12
Directly display
■
★
■
1
Eeprom failure
Page.29
F1
Directly display
□
★ ★
2
IPM failure
Page.31
F22
Directly display
★
★
■
3
AC current overcurrent
protection
Page.32
F3
Directly display
■
★
■
4
Communication error between module
board and main PCB board
Page.33
F20
Trouble record
■
★
□
5
High pressure protection
/
F19
Trouble record
■
★
□
6
Power over/under voltage
protection
Page.34
F27
Directly display
■
★
■
7
Compressor stall / press
instantaneous stop
/
F4
Directly display
■
★
■
8
Compressor discarging temperature
protection
Page.35
F8
Trouble record
■
★
□
9
Abnormal of DC motor
Page.30
F21
Directly display
□
●
□
★
10
Abnormal of piping sensor
Page.28
F7
Directly display
■
●
★
■
11
Suction temperature sensor
failure
Page.28
F6
Directly display
□
★
■
12
Abnormal of outdoor ambient sensor
Page.28
F25
Directly display
★
□
■
13
Abnormal of compressor discharge
sensor
Page.28
F13
Trouble record
■
★
□
16
Lack of refrigerant
/
F14
Trouble record
■
★
□
17
4-way valve reverse failure
/
F11
Directly display
■
★
■
18
Compressor jam (only for spdu)
Page.38
F28
Directly display
■
★
■
19
Module PWM select circuit error
Page.38
F15
Trouble record
■
★
□
20
Outdoor terminal block
temperature protection
/
F2
Trouble record
■
★
□
24
Instantaneous over-current
protection of the compressor
Page.32
F23
Trouble record
■
★
□
25
Compressor U-phase overcurrent
Compressor V-phase overcurrent
Compressor W-phase overcurrent
Page.32
F9
Trouble record
/
26
Module reset
/
F24
Trouble record
★
■
★
27
CT disconnection
/
F34
Trouble record
/
37
Outdoor coil protection
/
F35
Trouble record
■
★
□
38
Compressor driver board failure
/
F43
/
■
★
■
46
Model matching abnormality
/
Indoor
Malfunction
Outdoor
Malfunction
fault description
Reference
Page
Other display
Indoor displaying panel code
indication
Code indication
Outdoor
(LED1
flash
times)
Содержание AS25S2SF1FA-LW
Страница 4: ...2 5 ...
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 12: ... Piping diagrams Domestic air conditioner 5ˊPiping diagrams 10 ...
Страница 14: ...Domestic air conditioner 12 CN8 CN9 CN21 CN36 CN23 CN6 CN52 CN5 CN14 CN2 CN34 CN15 CN11 CN51 CN5 CN11 PCB ...
Страница 27: ...Seivice diagnosis Domestic air conditioner 8 Dimensional drawings 9 Center of gravity unit mm 25 ...
Страница 43: ...Circuit diagrams Domestic air conditioner 41 11 2 Circuit Diagrams ...
Страница 45: ...Removal Procedure 1 Domestic Air Conditioner Removal of front panel front panel Loosen the screw ...
Страница 46: ...Removal Procedure 2 Domestic Air Conditioner Lift up the control box cover 3 Remove the control box cover 2 ...
Страница 48: ...four 5 Removal Procedure 4 Domestic Air Conditioner 1 2 3 four Remove the casing ...
Страница 52: ...Removal Procedure 8 Domestic Air Conditioner motor cover ...
Страница 53: ...Removal Procedure 9 Domestic Air Conditioner ...