Commercial Air Conditioner
Model: AU182AFERA
AD182AMERA, AS182AVERA
Usage of the Sleep function
After starting, set the Run mode and press the Sleep
button.
Run mode
1. In cooling and dry
After starting of the Sleep operation, the temperature Will
be raised for 1 C higher than the set temperature 1 hour
later,and be raised for 1 C after another hour. It continues
under that condition for 6 hours, then the machine will be
switched off. The temperature is higher than the set
temperature so as to avoid catching cold in sleeping.
About 6 hours
The Sleep running starts
The Sleep running stops
Set the
temperature
Close down
the machine
In cooling and dry
1 hour
Raise 1 C
1 hour
Raise 1 C
Timer on/off operation
Remote control unit
TIMER operation
Set Clock correctly before starting Timer operation (refer to page 2)
You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or
after you fall asleep at night.
TIMER ON/OFF
(1) After unit start, select your desired operation mode.
Operation mode will be displayed on LCD.
(2) TIMER mode selection
Press TIMER button to change TIMER mode.
Every time the button is pressed, display changes as follows:
2. In heating
( the single-cooling conditioners do not
have the function)
After the Sleep running starts, the temperature will drop for 2 C after another
one hour. The temperature will raise for 1 C after 3 hours running under
the above temperature, and the conditioner will be closed down after running
for 3 hours. The temperature is lower than the set temperature so as to
avoid uneasiness in sleeping.
3. In automatic running
The conditioner will run under automatically selected working mode of sleeping.
4. In Fan running
The Sleep function is invalid.
Raise 1 C
Drop for 2 C
Drop for 2 C
About 3 hours
The Sleep running starts
The Sleep running stops
Set the
temperature
Close down
the machine
In heating
1 hour
1 hour
3 hours
ON
OFF
TEMP
HEALTH
FAN
MODE
SLEEP
SWING
CLOCK
TIMER
SET
LOCK
LIGHT
RESET
HEAT
Remote
controller
Select your desired TIMER mide (TIMER ON or TIMEROFF) ON or OFF will flash.
ON
ON
OFF
OFF
TIMER ON
TIMER OFF
TIMER ON-OFF
AM
12:00
PM
12:00
PM
12:00
AM
12:00
BLANK
-39-