10. TECHNICAL DATA

Operating Voltage:  

6VDC 

Typical Average Standby  
Current:

0.010 mA

Typical Test Current:  

55mA 

Typical Alarm Current:  

55mA 

Peak Trouble Pulse Current:  

4.73mA 

Peak Pulse Current:  

0.074mA 

Battery Life:  

At least 3 year under 
normal conditions with 
Lithium Batteries 

Battery Type:  

2xCR123 3V Lithium battery 

Low Battery Threshold:  

5.2VDC 

Low Battery Beep rate:  

One beep every 30 seconds 

Low Battery Life:  

At least 30 days from 
warning signal 

Operating Temperature:  

-10°C to 40°C 

Operating Humidity:  

10% to 85% RH, no 
condensation or icing 

Color:  

White 

Dimensions:  

Diameter: 148 mm 

Height:  

53 mm 

Alarm Sound Level:  

Exceeds 85dB at 3m 

Transmitter Characteristics: 

Nominal Center Frequency  

868 MHz 

Supervision Time  

65 min 

In order to continue improving the product, 

Haibrain

 

reserves the right to change specifications and/or designs 
without prior notice.  

Содержание PGSD834

Страница 1: ...USER MANUAL GSD834 20547 201200711 PGSD834 ALL RIGHTS RESERVED HAIBRAIN PGSD834 Wireless Smoke Detector...

Страница 2: ...ay that the built in siren will be heard by residents even when they are asleep If necessary install several smoke detectors For additional functionality you can also use the smoke detector in combina...

Страница 3: ...product Wrong positioning can cause an explosion INTRODUCTION The PGSD834 is a brand name smoke detector with an integrated Haibrain transmitter The PGSD834 Smoke Detector is for use with the Haibrai...

Страница 4: ...tectors figure A The smoke detector should be installed on the ceiling in the centre of the room Smoke rises and gathers in this area figure B and placing the smoke alarm here guarantees the earliest...

Страница 5: ...eries into the detector s batteries Compartment See Figure Batteries Compartment 3 The PGSD834 enters Test mode From the Programming menu select Devices Zones 911 Select the zone to which you want to...

Страница 6: ...fire to the alarm and damage the house We do not recommend testing with smoke as the results can be misleading unless special device is used 6 REPLACING THE BATTERIES Fresh batteries should last about...

Страница 7: ...en the red LED indicator see Figure flashes once in 30 seconds it indicates the detector is under normal operation When the red LED flashes very frequently and an audible alarm sounds simultaneously i...

Страница 8: ...ance Smoke alarms require a source of power to work This smoke alarm will not operate and the alarm will not sound if batteries are dead or not installed properly Smoke alarms may not be heard A sound...

Страница 9: ...ow Battery Threshold 5 2VDC Low Battery Beep rate One beep every 30 seconds Low Battery Life At least 30 days from warning signal Operating Temperature 10 C to 40 C Operating Humidity 10 to 85 RH no c...

Страница 10: ...formation about the disposal of your old equipment ple contact your local authorities waste disposal service or the shop where you purchase DECLARATION OF CONFORMITY Hereby Haibrain BV declares that t...

Страница 11: ...model numbers software audio video text and photographs rests with Haibrain B V Any use of the Content but without limitation distribution reproduction modification display or transmission without th...

Страница 12: ......

Отзывы: