REMOVING A THERMOSTAT FROM THE Z-WAVE NETWORK  

 
When prompted by Z-Wave primary or inclusion controller to exclude the thermostat from the network, press 
and release the ‘Hold’ button on the thermostat.  This will exclude the thermostat from the Z-Wave network. 
  
The thermostat supports the following command classes: 
 
COMMAND_CLASS_THERMOSTAT_MODE 
COMMAND_CLASS_THERMOSTAT_SETPOINT 
COMMAND_CLASS_THERMOSTAT_FAN_MODE 
COMMAND_CLASS_THERMOSTAT_FAN_STATE 
COMMAND_CLASS_THERMOSTAT¬_OPERATING_STATE 
COMMAND_CLASS_SENSOR_MULTILEVEL 
COMMAND_CLASS_ASSOCIATION 
COMMAND_CLASS_CONFIGURATION 
COMMAND_CLASS_VERSION 
COMMAND_CLASS_MANUFACTURER_SPECIFIC 
COMMAND_CLASS_SWITCH_BINARY 
COMMAND_CLASS_CLOCK 
 

COMMAND_CLASS_THERMOSTAT_MODE 

 
Upon power up, allow 10 seconds for the RC-112BZ thermostat to initialize.  After 10 seconds, a controller can 
set the mode, get the current mode, and get the modes supported by the thermostat. 
 

COMMAND_CLASS_THERMOSTAT_SETPOINT 

 
Upon power up, allow 10 seconds for the RC-112BZ thermostat to initialize.  After 10 seconds, a controller can 
change setpoints, get current setpoints, and request the setpoints that are supported by thermostat. 
 

COMMAND_CLASS_SENSOR_MULTILEVEL 

 
The RC-112BZ thermostat uses this command class to report the actual temperature. 
 

COMMAND_CLASS_ASSOCIATION 

 
Upon power up, allow 10 seconds for the RC-112BZ thermostat to initialize.  After 10 seconds, a controller can 
issue an Association Set, Remove, or Get command.  The thermostat must be associated with a controller to 
provide feedback. 
 

COMMAND_CLASS_CONFIGURATION 

 
Upon power up, allow 10 seconds for the RC-112BZ thermostat to initialize.  After 10 seconds, a controller can 
change individual register settings for the outdoor temperature.  The Parameter Number is 67.  The size of the 
data is a 1 byte value.  The Value is the temperature to which the register is set. 
 

Содержание OMNISTAT RC-112BZ

Страница 1: ...Maximum current 2 A on any circuit 3 A total Thermostat operating current less than 15 mA The following requirements must be observed for installation in Europe CE 1 This equipment must be installed i...

Страница 2: ...ting thermostat 3 Disconnect the wires going to each terminal on the thermostat Label each wire with the letter or number at the terminal 4 Remove the existing plate or base from the wall MOUNTING Whe...

Страница 3: ...tat push all excess wiring into the hole in the wall Plug the hole with the supplied insulating foam to ensure an accurate temperature reading by the thermostat Align the tabs of the thermostat face w...

Страница 4: ...energized for cooling B Terminal is energized for heating In most applications the reversing valve is energized for cooling and should be connected to the O terminal If the heat pump requires the rev...

Страница 5: ...5 5 Figure 5...

Страница 6: ...6 2 To configure the display backlight to always be on set the JP2 Select Backlight Mode jumper to the ON position between the middle and bottom pin on the connector See Figure 6 3 To configure the di...

Страница 7: ...a convenience to the installer the compressor start up protection delay can be canceled To cancel the delay press the Prog key 3 times then press the Fan key 2 times If the thermostat or system does n...

Страница 8: ...ured with the following system options WITH NO EEC EEC 0 8 Auto changeover no fan with heat 1 9 Auto changeover fan on with heat 4 12 Manual changeover no fan with heat 5 13 Manual changeover fan on w...

Страница 9: ...r displays add 16 to each value The default setting is 1 04 Calibration offset This item is used to raise or lower the current temperature reading by 1 degree Fahrenheit or 1 2 degree Celsius If this...

Страница 10: ...nimum time set by this item When the cooling system turns off it must remain off for a minimum time set by this item Setting Cycles per hour maximum 5 6 6 5 7 4 8 3 7 10 3 The recommended setting is 8...

Страница 11: ...tem operation before this reminder is displayed Days Counting down from 10 0 The filter reminder can be disabled by setting this item to 60 16 System runtime This week This item logs the amount of tim...

Страница 12: ...System runtime This week 17 System runtime Last week WIRELESS COMMUNICATIONS WITH HAI CONTROLLER This thermostat has been preprogrammed with energy saving settings recommended under the EPA Energy St...

Страница 13: ...r can set the mode get the current mode and get the modes supported by the thermostat COMMAND_CLASS_THERMOSTAT_SETPOINT Upon power up allow 10 seconds for the RC 112BZ thermostat to initialize After 1...

Страница 14: ...and application version from the device COMMAND_CLASS_MANUFACTURER_SPECIFIC Upon power up allow 10 seconds for the RC 112BZ thermostat to initialize After 10 seconds a controller can request a Manufa...

Страница 15: ...tween the equipment and receiver Consult the dealer or an experienced radio TV technician for help TROUBLESHOOTING TIPS SYMPTOM ACTION TO TAKE 1 Check power to the thermostat 2 Check wiring diagrams T...

Страница 16: ...Pump is not able to meet load due to cold weather Aux Heat On Too Often 2 Thermostat is in EM Heat mode Set thermostat to Heat or Auto mode In EM Heat mode the auxiliary heat is turned on SYMPTOM ACTI...

Отзывы: