WaterMax RO Owner’s Manual
9/2020
13
Checklist Before Installation
Refer to this checklist before installation.
WaterMax
®
H3500 and H6000 are designed for chlorinated municipal and well water supplies.*Refer to RO
Specifications.
WaterMax
®
Water Softener or additional types of pretreatment are highly recommended should your water not
meet water quality or characteristics standards. Should you have any questions about your water not meeting
these standards, contact your Hague dealer.
Water Quality
—If the water supply contains sand, sulfur, bacteria, iron bacteria, tannins, algae, oil, acid, or
other unusual substances, consider pre-treating the water to remove these contaminants before the water
supply enters the appliance, unless the appliance is represented as being capable of treating these
contaminants in its specifications. Consider purchasing and installing a
WaterMax
®
water conditioner or filter.
Water Pressure
—Not less than 40 psi (276 kPa) constant for
WaterMax
®
RO appliances.
Drain
—Drain the appliance to an appropriate drain that complies with all local and state plumbing codes. To
prevent back-siphoning, provide an adequate air gap or a siphon break. See
Installation Steps and Start-Up
Procedures
.
Water Characteristics: pH
—The appliance requires a pH of between 5.0 and 9.0 for H3500, H6000, and
LC100P models.
Water Characteristics: Iron and/or manganese
—A test to determine iron or manganese levels is necessary.
Should iron exceed 0.1 ppm, or manganese exceed 0.05 ppm, additional pretreatment is recommended.
If you have any questions, contact your Hague dealer.
Precautions
Do
1.
Comply with all state and local, building, plumbing, and electrical codes.
2.
Check all fittings and locking clips to ensure none are loose.
3.
Install the appliance after the pressure tank on well-water installations.
4.
Connect to the cold water supply only!
Do Not
1.
Do not install if checklist items are not satisfactory. See
Checklist Before Installation
.
2.
Do not install if the incoming or outlet piping water temperature exceeds 113°F (45°C). See
Specifications
.
3.
Do not use to treat water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the appliance.
4.
Do not allow your appliance to freeze.
5.
Do not tie into hot water feed.
I
NSTALLATION AND
M
AINTENANCE
I
NFORMATION
Содержание WaterMax H3500
Страница 16: ...WaterMax RO Owner s Manual 9 2020 16 Typical Flow Diagram WaterMax H3500 Figure 3 WaterMax H3500 Flow Diagram...
Страница 42: ...Notes...