RO Specifications
Model Part #
H6000
1
3140
H3500
1
2141
LC100P
N/A
Membrane
TFC
TFC
TFC
Production Rates
Gallons per day
2
Liters per day
2
WQA gpd
3
WQA lpd
3
N/A
N/A
19
72
N/A
N/A
29
109.77
100
378
N/A
N/A
Water Pressure
(Min-Max) psi (kPa)
40–100
(276–689)
40–100
(276–689)
40–100
(276–689)
Water Temperature
(Min-Max) Deg. F (Deg. C)
40–113
(4.4–45)
40–113
(4.4–45)
40–113
(4.4–45)
Chlorine Tolerance (ppm)
0
0
0
Max. Hardness (Gr. pg)
10
10
10
Max. Iron (ppm)
< 0.1
< 0.1
< 0.1
Max. Mang. (ppm)
< 0.05
< 0.05
< 0.05
pH Limit
5.0–9.0
5.0–9.0
5.0–9.0
Max. TDS Limit (ppm)
2000
2000
2000
Hydrogen Sulfide (ppm)
0.00
0.00
0.00
Max. Turbidity (NTU)
1.0
1.0
1.0
TDS Rejection
Typical @ 60 psi (414 kPa)
WQA @ 50 psi (345 kPa)
N/A
WQA=90.1%
N/A
WQA=90.1%
97%–98%
N/A
Storage–Gal. (L)
3 (11.35)
3 (11.35)
Optional
7
Water Supply
Municipal, Well, Non-
Chlorinated
Municipal, Well, Non-Chlorinated Municipal, Well, Non-Chlorinated
Treatment Stages
5
5
4
4
Prefiltration
5 Micron
Sediment, GAC
1 Micron
Sediment/ Carbon Block
5 Micron,
20-inch
Sediment, GAC
PCF
Standard
Standard
N/A
Postfilter
GAC
GAC
GAC
Height–inches (cm)
16.75 (42.5)
16.75 (42.5)
28.75 (73)
Width–inches (cm)
14.5 (36.8)
14.5 (36.8)
14.5 (36.8)
Depth–inches (cm)
7 (17.8)
7 (17.8)
7 (17.8)
Weight–lb (kg)
35 (15.9)
35 (15.9)
40 (18.1)
Efficiency Rating
5
8.2%
13.7%
N/A
Recovery Rating
6
16.6%
27.2%
N/A
1
H6000 and H3500 are certified by WQA to NSF/ANSI Standard 58 for specific
performance claims as verified and substantiated by the test data. These are the only
units certified by WQA.
2
Product output is measured to atmosphere with feed water of 77°F (25°C), 60 psi
(414 kPa) and 360 ppm TDS.
3
WQA production is measured against a pressure tank @ 5 psi (34 kPa) backpressure,
77°F (25°C), 50 psi (345 kPa) and 750 mg/L ± 40 mg/L TDS,
1 NTU turbidity 7.5 ± 0.5 pH, 1 US/cm.
4
LC100P uses dual function prefilter for chlorine taste and odor removal.
Note:
Actual production rates may vary depending on water temperature, pressure, TDS
level and membrane type.
5
Efficiency Rating means the percentage of the influent water to the system that is
available to the user as reverse osmosis treated water under operating conditions that
approximate typical daily usage.
6
Recovery Rating means the percentage of the influent water to the membrane portion of
the system that is available to the user as reverse osmosis treated water when the
system is operating without a storage tank or when the storage tank is bypassed.
7
Storage tank not included. Can use any size storage tank.
This reverse osmosis system contains a replaceable component critical to the efficiency of
the system. Replacement of the reverse osmosis component should be with one of
identical specifications, as defined by the manufacturer, to assure the same efficiency and
contaminant reduction performance.
Содержание WaterMax H3500
Страница 16: ...WaterMax RO Owner s Manual 9 2020 16 Typical Flow Diagram WaterMax H3500 Figure 3 WaterMax H3500 Flow Diagram...
Страница 42: ...Notes...
Страница 43: ...2013 100338947 9 2020 Notes...