WaterMax RO Owner’s Manual 

9/2020 

26 

Changing Filters, Cont. 

Changing the Membrane 

We strongly recommend that you seek the services of a Hague dealer to change your RO membrane, as well 

as perform a complete check-up and re-sanitize your appliance. 
Be sure to order the proper membrane for your appliance: TFC. See 

Assembly and Parts, RO Assembly

1.

 

Turn off the ball valve on top of the storage tank 1/4 turn clockwise (See Figure 2).  

2.

 

Turn off the feed water supply valve (See Figure 11).  

3.

 

Lift the black handle on the dispensing spigot and wait at least five minutes for the pressure to be 

relieved from the appliance.  

4.

 

Detach the red tubing connection on the pressure vessel end cap. (See Figure 17)  

5.

 

Remove the pressure vessel end cap by turning counterclockwise.  

6.

 

Remove the membrane, use needle nose pliers to grab the product tube and pull the membrane out of 

the housing.  

7.

 

Sanitize the appliance. (See 

Sanitizing the WaterMax RO Appliance

).  

8.

 

Insert the new membrane, making sure that the brine seal (See Figure 15)

 

and the product water 

O-Rings are seated. Lubricate the brine seal and O-Rings with glycerin. 

Caution:

 Do not touch the filter(s) with your bare hands. Peel the wrapper and use as a sleeve to 

prevent contamination. Wearing clean latex gloves can help prevent hand contact.  

9.

 

Inspect the O-Rings on the pressure vessel end cap and lubricate with glycerin. Replace if damaged or 

out of round.  

10.

 

Replace the end cap by turning clockwise.  

11.

 

Reattach the tubing to the pressure vessel end cap. 

Changing the Carbon Post-Filter 

1.

 

Turn off the ball valve on top of the storage tank 1/4 turn clockwise. (See Figure 2.)  

2.

 

Turn off the feed water supply valve (See Figure 11).  

3.

 

Lift the black handle of the dispensing spigot and wait at least five minutes for the pressure to be 

relieved from the system.  

4.

 

Remove the Carbon Post-Filter housing by turning it counterclockwise (as viewed from the bottom) and 

dispose of the spent cartridge. If you encounter difficulty, use the filter wrench provided with your RO.  

5.

 

Wash out the Post-Filter housing using warm soapy water and rinse thoroughly.  

6.

 

Be sure the O-Ring is properly seated in the groove located in the top of the post-filter housing and 

lubricate with glycerin. 

7.

 

Sanitize the storage tank. (See 

Sanitizing the WaterMax RO Appliance

.)  

8.

 

Insert the new Carbon Post-Filter of the same type and reattach the Post-Filter housing. 

9.

 

Turn on the feed water supply valve.  

10.

 

Turn on the storage tank valve.  

11.

 

Inspect for leaks.  

12.

 

Allow the first two tanks full of water to flush the Carbon Post-Filter before use.  

Содержание WaterMax H3500

Страница 1: ...S A AP PP PL LI IA AN NC CE E O OW WN NE ER R S S M MA AN NU UA AL L A AN ND D I IN NS ST TA AL LL LA AT TI IO ON N G GU UI ID DE E M MO OD DE EL LS S H H3 35 50 00 0 H H6 60 00 00 0 A AN ND D L LC C1...

Страница 2: ...usions and Limitations on Warranty This warranty is null and void unless the Hague Appliance was purchased from an independent Hague dealer THERE ARE NO WARRANTIES OTHER THAN THOSE DESCRIBED IN THIS W...

Страница 3: ...n for Pentavalent Arsenic Treatment Appliances 12 INSTALLATION AND MAINTENANCE INFORMATION 13 Checklist Before Installation 13 Installation Tool List 14 Installation Diagram 15 Typical Flow Diagram 16...

Страница 4: ...ent Hague dealer install and maintain this appliance Note The manufacturer reserves the right to make specification and product changes without prior notice This manual is for installation operation a...

Страница 5: ...ter Post Carbon Flow Restrictor Check Valve Sanitize Air Precharge Shutoff Valve Water Pressure Water Temperature pH Feed TDS Product TDS Rejection Recovery Notes Important Meeting operational mainten...

Страница 6: ...from water at the molecular level By using your household water pressure to squeeze your water against a special membrane water molecules are separated from impurities Rejected dissolved solids are a...

Страница 7: ...ditional tanks may be added to your appliance to provide more storage space permitting 3 Your WaterMax RO Drinking Water Appliance can be connected to your automatic ice maker and cold water dispenser...

Страница 8: ...Model H6000 If you are using softened water replace your Sediment Pre Filter annually If you are not using softened water the replacement interval will vary Every six months schedule an inspection an...

Страница 9: ...change is needed Consult your Hague dealer for additional monitoring devices or water check programs Note The installation of your WaterMax RO appliance on a soft water supply will greatly increase th...

Страница 10: ...tial for these appliances to perform to specification as advertised FACTORS WHICH AFFECT THE LIFETIME AND PERFORMANCE OF YOUR WATERMAX RO 1 TYPE OF MEMBRANE Thin Film Composite TFC Up to 2 000 PPM TDS...

Страница 11: ...Max NTU 1 0 1 0 TDS Max ppm 2000 2000 CAUTION Contaminants in excess of the established limits will require pretreatment WARNING Do not use with water that is microbiologically unsafe or of unknown q...

Страница 12: ...at http www epa gov ORD publications ordpubs html Private water supplies and waters that do not have detectable free chlorine residuals should be analyzed to determine the form s of arsenic present an...

Страница 13: ...all local and state plumbing codes To prevent back siphoning provide an adequate air gap or a siphon break See Installation Steps and Start Up Procedures Water Characteristics pH The appliance requir...

Страница 14: ...h High speed drill bit with 3 8 inch shank for non air gap spigot Air pressure test gauge 1 20 psi 1 inch High speed drill bit with 1 2 inch shank for air gap spigot 7 8 inch chassis punch 1 2 inch Dr...

Страница 15: ...3500 and H6000 Figure 2 Installation Diagram Notes 1 For maximum flow keep yellow tubing to tank and blue tubing to spigot as short as practical 2 Install feed water line on COLD WATER LINE ONLY 3 Ins...

Страница 16: ...WaterMax RO Owner s Manual 9 2020 16 Typical Flow Diagram WaterMax H3500 Figure 3 WaterMax H3500 Flow Diagram...

Страница 17: ...ppliance Failure to install as instructed will void the product warranty Step 1 Study the Installation Diagram Study the overall installation diagram before proceeding to familiarize yourself with the...

Страница 18: ...sert tube E Pull to check security The fitting grips before it seals Pull on the tube to check that it is secure Test the appliance before leaving the site or before use C Push up to tube stop F Disco...

Страница 19: ...illing a porcelain clad steel or cast iron sink A Mark the sink location for the center of the faucet Be sure the location you select is not over a reinforcing rib Check the location from below B Grin...

Страница 20: ...replace the red locking clip Slip the 1 4 inch black tube onto the small hose barb on the base of the spigot C Slip one end of the loose 3 8 inch black tube over the large hose barb on the base of the...

Страница 21: ...upply valve Do not overtighten D Reconnect the riser tube to the other end of the feed water supply valve Do not overtighten Caution A longer riser tube assembly will be required if a gentle loop cann...

Страница 22: ...nch hole through one side of drain pipe only C Peel off the white backing from the drain gasket and apply the gasket to the port connection of the drain saddle Make sure to align the drain saddle to t...

Страница 23: ...e they are tight with locking clips in place B Turn on the feed water and check for leaks C Open the valve on top of the storage tank D The appliance is now in operation Step 9 Operation Procedure A O...

Страница 24: ...h your RO 5 Inspect the Pre Filter If it is visibly dirty discard it 6 Wash out the filter housing using warm soapy water and rinse thoroughly 7 Sanitize the appliance See Sanitizing the WaterMax RO A...

Страница 25: ...ure 2 2 Turn off the feed water supply valve See Figure 11 3 Lift the black handle of the dispensing spigot and wait at least five minutes for the pressure to be relieved from the system 4 Remove the...

Страница 26: ...r and use as a sleeve to prevent contamination Wearing clean latex gloves can help prevent hand contact 9 Inspect the O Rings on the pressure vessel end cap and lubricate with glycerin Replace if dama...

Страница 27: ...e to between 5 and 7 psi 34 and 48 kPa 2 Close the RO spigot 3 Remove the pre filter housing s and discard the spent cartridge s Wash out the housing s with warm water and soap using a bottlebrush and...

Страница 28: ...Option 2 1 Follow steps 1 and 2 as outlined above then proceed as follows 2 Remove the Pre Filter housing and discard the spent cartridge Wash out the housing with warm water and soap using a bottleb...

Страница 29: ...s Manual 9 2020 29 Assembly and Parts Feed Water Service Valve Assembly Figure 12 Feed Water Assembly Part Description Quantity 1 100236312 Feed Water Service Valve Assembly 1 2 100236204 1 4 inch Lo...

Страница 30: ...ad Free Figure 13 RO Air Gap Spigot Lead Free Part Description Quantity 1 100236513 Filter housing wrench 1 2 100236281 Air gap spigot assembly 1 3 100236285 Spigot adapter 3 8 inch x 7 16 inch J G 1...

Страница 31: ...ner s Manual 9 2020 31 Assembly and Parts Cont Drain Saddle Assembly Figure 14 Drain Saddle Assembly Part Description Quantity 1 100236147 Drain saddle assembly 2 Piece Plastic 1 2 100236202 3 8 inch...

Страница 32: ...WaterMax RO Owner s Manual 9 2020 32 Assembly and Parts Cont RO Assembly Front View Figure 15 H3500 RO Assembly Front View...

Страница 33: ...dels 1 8 100236243 Membrane housing black 1 9 100236204 Locking clip 1 4 inch 3 10 100236432 Male elbow 1 4 inch x 1 4 inch Plastic 3 11 100236169 Prolonged contact filter 12 inch 1 12 100236179 Inlin...

Страница 34: ...WaterMax RO Owner s Manual 9 2020 34 Assembly and Parts Cont RO Assembly Back View Figure 16 H3500 RO Assembly Back View...

Страница 35: ...100236169 Prolonged contact filter 12 inch 1 5 100236514 Plug in elbow 1 4 inch tube x 1 4 inch Stem 6 6 100241864 Male elbow 3 8 inch x 1 4 inch Plastic 1 7 100236202 Locking clip 3 8 inch 3 8 10023...

Страница 36: ...WaterMax RO Owner s Manual 9 2020 36 Assembly and Parts Cont RO Assembly Top Back View Figure 17 H3500 RO Assembly Top Back View...

Страница 37: ...2 Membrane housing cap black with O Ring 1 12 100236432 Male elbow 1 4 inch x 1 4 inch 2 13 100236135 2 inch vessel clip 2 14 100242366 Permeate pump shutoff valve 1 15 100236306 Screw 10 32 2 16 1002...

Страница 38: ...18 Storage Tank Assembly Part Description Quantity 1 100236440 Tank shutoff valve 3 8 inch x 1 4 inch plastic 1 2 100236202 3 8 inch Locking clip 1 3 100236124 RO storage tank 4 4 gallon 16 7 L capac...

Страница 39: ...al Hague dealer No water or not enough water Feed water shut off Turn on your feed water valve Low feed pressure See Filter Specifications chart to verify minimum feed pressure for your model A pre fi...

Страница 40: ...e cubes are cloudier Change ice cube mold shape make cubes manually if using automatic Let water sit to release dissolved air before freezing RO membrane is bad Membrane fouled hydrolyzed ruptured or...

Страница 41: ...ing6 16 6 27 2 N A 1 H6000 and H3500 are certified by WQA to NSF ANSI Standard 58 for specific performance claims as verified and substantiated by the test data These are the only units certified by W...

Страница 42: ...Notes...

Страница 43: ...2013 100338947 9 2020 Notes...

Страница 44: ...000 systems are certified by the Water Quality Association according to NSF ANSI 58 NSF ANSI 372 and CSAB483 1 see performance data sheet for specified claims Hague Quality Water Int l 4343 South Hami...

Отзывы: