20
Maximizer
®
97 Owner’s Manual
OR-05/18/15
Quality Water International
®
Mode Setting Chart
This section provides guidance for using different service settings to achieve the desired capacity.
Mode Setting Chart
97 Maximizer
97MM
Mode 1 and Mode 2
Yes
Regeneration Frequency
Mode 1 only
96 hour regeneration (if iron present—yes)
1
Yes or No
#1 Salt Setting
Backwash 1 (minutes)
01.0
Brine/Rinse (minutes)
19.5
Backwash 2 (minutes)
03.0
Capacity–grains @ salt–lb (grams @ salt–kg)
5,400 @ 1 (350 @ 0.5)
#2 Salt Setting
Backwash 1 (minutes)
01.0
Brine/Rinse (minutes)
22.0
Backwash 2 (minutes)
03.0
Capacity–grains @ salt–lb (grams @ salt–kg)
13,700 @ 3 (888 @ 1.4)
#3 Salt Setting
Backwash 1 (minutes)
2
01.0
Brine/Rinse (minutes)
26.0
Backwash 2 (minutes)
03.0
Capacity–grains @ salt–lb (grams @ salt–kg)
23,700 @ 6 (1,540 @ 2.7)
#4 Salt Setting
3
Backwash 1 (minutes)
2
01.0
Brine/Rinse (minutes)
30.0
Backwash 2 (minutes)
03.0
Capacity–grains @ salt–lb (grams @ salt–kg)
30,800 @ 9 (2,000 @ 4.1)
1
If iron is present in water supply, use salt setting #3 or #4.
2
If iron is present in the water supply, set Backwash 1 to 7 minutes.
3
Do not use this salt setting in California.