SECTION 9 –
MAINTENANCE AND STORAGE
9-20
Dual Product Solution Line Strainers (2)
-If Equipped
Maintain consistent application rates by
inspecting both Solution Line Strainers
(Primary Solution Line Strainer located
beneath the center right-hand side of
machine, and the Secondary Solution Line
Strainer located near the front right-hand
side of machine) daily for blockage. Clean
the strainer screen as needed and ensure
the gasket is in place before reinstalling the
screen.
NOTE: Wear appropriate PPE while
removing and cleaning the strainer
screen.
Section Strainers
(80-Mesh Strainer Screens)
Two (2) Section Strainers are located on
the transom and filter impurities to aid in the
avoidance of spray nozzle buildup. Remove
bottom section of each strainer and clean
strainer screen as needed.
NOTE: Wear appropriate PPE while
removing and cleaning the strainer
screen.
To Clean the Strainer Screens
1. Rotate the Section Strainer Inlet Valve
(A) in the CLOSED position.
CAUTION
Ensure both Solution Tank Valves and
the Agitation Valve are CLOSED before
servicing the Solution Line Strainers.
Failure to comply may result in chemical
contact.
Solution Line Strainer
(Located beneath the center
right-hand side of machine)
-Typical View
Solution Line Strainer -
Primary
(Located beneath the center
right-hand side of machine)
-Typical View
Solution Line Strainer -
Secondary
(Located near the front
right-hand side of machine)
-Typical View