94
Installation
G
B
You can perform programming and set
parameters with the remote-controlled socket
placed on a table and connected to the mains power
outlet via an extension lead. Disconnecting the socket
does not delete programming.
Install your S761-22 by plugging it into a discon-
nectable 230 V – 50 Hz (16 A) mains power outlet with
earthing protection and then plug the device to be con-
trolled into the socket.
Your remote-controlled socket must be installed:
• inside your home (never outside),
•
more than 1.5 m away from the device to be con-
trolled if this is likely to cause interference (neon
lighting, strobe, etc.).
Total maximum output power
(depending on type of load):
230 AC halogen lamp
500 W
12 V ELV halogen lamp 1500 W
Incandescent lamp
1500 W
Low consumption bulb
450 W
Fluorescent tube
400 W
You can now move on to the programming step.
Programming LED
Programming key
†
†
Make sure there is a distance of at least 2 m between each product, except between two detectors.