18
Putting power to machine and testing operation
# Swing the blade guard over the blade.
Wind blade fully up
Wind blade to be on the 90 degree stop.
# Ensuring the isolation switch on the RH side of the machine is in the off position ( 0 ), the
emergency stop on the front panel is depressed and the scouring saw switch in the OFF position,
Have a fully licensed Electrician put power to the machine.
# Turn the isolation switch to ON ( 1 ) position and release the emergency stop button.
# Check correct rotational direction of them main blade by quickly pressing the MAIN SAW ON
Button and straight after that main saw OFF Button
The main blade should spin clockwise.
If it does not, have licensed electrician reverse the phase direction of the power to the machine.
Retest as above and when all is correct, switch on the SCOURER BLADE,
This should go anticlockwise,
(NB the Scouring blade will not operate unless the main blade is switched on)
# The Blade Angle LED may be flashing. If so press and HOLD down the small red reset button
under the LED panel for 10 to 20 seconds.
LED will set itself to 00.00
NB: the resetting of the LED may have to be done if the Emergency stop is pressed or there is a power
cut when the blade is not on 90 degree cut
Always wind blade to 90 deg before resetting to 00.00
Reset button to
Zero DRO
Main blade On/Off
Buttons
Scouring blade On/Off switch
Will only operate when main blade is
turned on.
Emergency Stop Button Only
Do not use to turn blades off in general use
Blade Angle LED
Power on Light