background image

 

 

 

 

10 

 

 

5.52.693.01.01.00 

 

 

   

CAUTION!

 

Transport  may  only  be  done  by  qualified  personnel.  No  liability  for  any  damage  resulting  from  improper 
transport or improper storage. 

 

3.1 

Transport 

 The devices are checked and if so adequately packed before delivery. 

  Do not throw or drop the equipment.  

  Use adequate means of transport. 

Transport and means of transport must be suitable for the local conditions. 

3.2 

Safety device for transport 

 

NOTICE!

 

Should a safety device for transport exist, please remove it before commissioning. 

3.3 

Storage 

  Store the equipment at a clean and dry place. 

  Protect the equipment against dirt, humidity and damage by an appropriate cover. 

  Protect hooks, wire ropes, chains and brakes against corrosion. 

 

 

   

DANGER!

 

Units that show corrosion must be taken out of service!

 

 

Description  

 

 

 

4.1 

Areas of application 

The devices must be as far as possible installed in a covered room. 

If they are used in the open, protect the units against the effects of weather such as rain, hail, snow, direct 
sunshine,  dust,  etc.  -  we  recommend  to  use  a  cover  in  parking  position.  If  the  device  is  set  up  in  a 
continuously  humid  environment  with  strong  temperature  fluctuations,  the  correct  functionings  are 
endangered by the forming of condensation. 

NOTICE!

 

Use only in the intended atmosphere with a humidity of up to 100%, but not under water! 

 

 

Depending on the type of device, it is suitable for use in area at risk from explosion in the EX-classification 
stated. 

The EX-classification is mentioned on the EX-type plate on the hoist. The use of the unit is only allowed for 
the EX-classification mentioned on the EX-type plate or lower EX classification.  

 

 

 

Содержание 32/20EX

Страница 1: ...2D Ex h IIIA T135 C Db II 2G Ex h IIB T3 Gb or II 2D Ex h IIIA T200 C Db DANGER Not to be used with IIC gases and IIB gases hydrogen sulphide and ethylene oxide and light metal and shock sensitive du...

Страница 2: ...Information 3 2 Safety 3 2 1 Warning notice and symbols 3 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 5 2 5 Basic safety measures 5 2 6 Explosio...

Страница 3: ...damage immediately to the forwarding agent This manual serves for safe and efficient use of this hoist Illustrations serve to explain something and may differ from the illustration of the existing un...

Страница 4: ...uipment i e regarding organization of work work flow and human resources In particular the owner user must ensure that The unit is only used appropriately The device is only operated in a fault free f...

Страница 5: ...21 Devices of this category have been specially modified and labeled by the manufacturer DANGER The permissible ambient temperature must not be exceeded Moving horizontally on beams DANGER The use is...

Страница 6: ...ide and light metal and shock sensitive dusts No use in temperature class T5 or T6 It is not allowed to use the equipment in area at risk from explosion where gas AND dust does both exist at the same...

Страница 7: ...ding e g c construction safety k encapsulation of liquids IIB explosion group II gases IIA IIB IIC limit gap widths MESG 0 9 mm limit gap widths MESG 0 9 to 0 5 mm limit gap widths MESG 0 5 mm T4 Temp...

Страница 8: ...ixtures for T5 do not occur with normal use and only very rarely occur for T6 for specific gas air mixtures such as carbon disulphide IIC our hoists are not rated for these temperature classes and mus...

Страница 9: ...5 52 693 01 01 00 9 2 6 4 Explosion hazards recognizing and preventing 3 Transport and Storage...

Страница 10: ...GER Units that show corrosion must be taken out of service 4 Description 4 1 Areas of application The devices must be as far as possible installed in a covered room If they are used in the open protec...

Страница 11: ...all standard beams with inclined and parallel flanges Side plates Made of steel plate with integrated wheel fracture supports load bars Device with 2 load bolts Different bolt lengths are available f...

Страница 12: ...e inner side X increases or from the inner to the outer side X decreases Washers 6 and rubber discs depended on type leave a distance for the load hook It is important that the load hangs in the middl...

Страница 13: ...mm 1 1 5 mm each side bigger and for trolleys from 4 t up 3 5 mm 1 5 2 5 mm each side bigger than the flange width B of the beam 6 4 Tools 7 Control Only people that are familiar with the operation o...

Страница 14: ...regard to design and kind of use The license will be given to qualified person be the approved supervision authorities Z S 9 Safety check Before putting into service initially or when putting back in...

Страница 15: ...BER Renolit FEP 2 Alvania EP 2 Unirex EP 2 Mobilux EP 2 MULTIS EP2 Stabylan 5006 Optimol Viscoleb 1500 Kl beroil 4UH 1 1500 Wolfracoat 99113 Chain lubricant OKS 451 13 2 Lubricant for food industry S...

Страница 16: ...datory that all steps for decommissioning the machine are carried out in the indicated sequence First secure the working area for decommissioning leaving plenty of space Read the chapter Safety instru...

Отзывы: