  Pay attention to the accident prevention regulations (UVV). 

  Should the hoist be used outside of Germany, please pay attention to the national regulations that apply. 

  Supporting structures and load-attached devices used in conjunction with this equipment must provide an 

adequate safety factor to handle the rated load plus the weight of the equipment. In case of doubt, consult 
a structural engineer. 

  If the equipment has not been used for a period of time, carry out visual checks of all main components 

such  as  chains,  load  hooks  etc.  and  replace  any  damaged  parts  with  new,  original  spare  parts  before 
putting the equipment back into operation! 

  Do not use a hoist that is defective, pay attention to any abnormal noise it makes during operation. 

  Stop working immediately in case of disturbances and remedy failures. 

  Any damage and faults must be reported to a responsible supervisor immediately. 

  If the unit is put into motion, any persons in the immediate vicinity must be informed by calling to them! 

  Please pay attention to the regulations for load carrying devices UVV for both positive and non-positive 

methods of attaching loads. 

 

  The  lifting tackle or the  load  must  be securely attached  to the  hook  and be seated at the bottom of the 

hook. 

  The safety catch of hooks must be closed. 

  When charged, the housing may not be in contact somewhere. 

 

 

   

DANGER!

 

Special safety measures for use in areas prone to explosion.

 

  Not to be used with IIC gases and IIB gases hydrogen sulphide, ethylene oxide and light metal and shock 

sensitive dusts! 

  No use in temperature class T5 or T6. 

  It is not allowed to use the equipment in area at risk from explosion where gas AND dust does both exist 

at the same time! 

  During assembly and operation of explosion-proof equipment, the relevant regulations of i.e. BG-Chemie 

about the use of equipment in area at risk from explosion, must be adhered to by the user/owner. 

  Please make sure that external ventilation is sufficient. 

  Please wear conductive shoes. Gloves should have a shunt resistance of < 10

8

  It is not allowed to take off clothes. 

  The  surface  temperature  of  the  devices  could  increase  by  a  variety  of  external  circumstances.  For  this 

reason, the surface temperature is to be monitored. 

  Avoid ignitable dust deposits. 

  Remove dust deposits daily before commencing work and ensure that dust cannot settle between moving 

parts. 

  Never remove dust with compressed air - remove it with a wet bolt of cloth. 

  Defective  units  or  units  that  show  abrasion  of  its  surface  rust on  chains, hooks,  or  suspension  devices, 

must be taken out of service. 

  Please observe the prescribed intervals. 

  Assembly and maintenance work must only be carried out in an atmosphere not prone to explosion. 

  Check the grease level of the bearings regularly 

  Exchange friction surfaces in time and (an exception to this are electric units - maintenance of the brakes 

must only be effected by HADEF). 

  Protect the device from impact, friction, rough handling and moisture. 

 

Special scope 

Use of different EX-zones is depended from the EX-classification of the unit. Find the EX-classification on its 
type plate. 

 

Unit classified 

in EX-classification 

 

No use 

in EX-zone 

3G 

  0,20,1,21,22 

3D 

  0,20,1,21,2 

2G 

  0,20,21,22 

Содержание 32/20EX

Страница 1: ...2D Ex h IIIA T135 C Db II 2G Ex h IIB T3 Gb or II 2D Ex h IIIA T200 C Db DANGER Not to be used with IIC gases and IIB gases hydrogen sulphide and ethylene oxide and light metal and shock sensitive du...

Страница 2: ...Information 3 2 Safety 3 2 1 Warning notice and symbols 3 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 5 2 5 Basic safety measures 5 2 6 Explosio...

Страница 3: ...damage immediately to the forwarding agent This manual serves for safe and efficient use of this hoist Illustrations serve to explain something and may differ from the illustration of the existing un...

Страница 4: ...uipment i e regarding organization of work work flow and human resources In particular the owner user must ensure that The unit is only used appropriately The device is only operated in a fault free f...

Страница 5: ...21 Devices of this category have been specially modified and labeled by the manufacturer DANGER The permissible ambient temperature must not be exceeded Moving horizontally on beams DANGER The use is...

Страница 6: ...ide and light metal and shock sensitive dusts No use in temperature class T5 or T6 It is not allowed to use the equipment in area at risk from explosion where gas AND dust does both exist at the same...

Страница 7: ...ding e g c construction safety k encapsulation of liquids IIB explosion group II gases IIA IIB IIC limit gap widths MESG 0 9 mm limit gap widths MESG 0 9 to 0 5 mm limit gap widths MESG 0 5 mm T4 Temp...

Страница 8: ...ixtures for T5 do not occur with normal use and only very rarely occur for T6 for specific gas air mixtures such as carbon disulphide IIC our hoists are not rated for these temperature classes and mus...

Страница 9: ...5 52 693 01 01 00 9 2 6 4 Explosion hazards recognizing and preventing 3 Transport and Storage...

Страница 10: ...GER Units that show corrosion must be taken out of service 4 Description 4 1 Areas of application The devices must be as far as possible installed in a covered room If they are used in the open protec...

Страница 11: ...all standard beams with inclined and parallel flanges Side plates Made of steel plate with integrated wheel fracture supports load bars Device with 2 load bolts Different bolt lengths are available f...

Страница 12: ...e inner side X increases or from the inner to the outer side X decreases Washers 6 and rubber discs depended on type leave a distance for the load hook It is important that the load hangs in the middl...

Страница 13: ...mm 1 1 5 mm each side bigger and for trolleys from 4 t up 3 5 mm 1 5 2 5 mm each side bigger than the flange width B of the beam 6 4 Tools 7 Control Only people that are familiar with the operation o...

Страница 14: ...regard to design and kind of use The license will be given to qualified person be the approved supervision authorities Z S 9 Safety check Before putting into service initially or when putting back in...

Страница 15: ...BER Renolit FEP 2 Alvania EP 2 Unirex EP 2 Mobilux EP 2 MULTIS EP2 Stabylan 5006 Optimol Viscoleb 1500 Kl beroil 4UH 1 1500 Wolfracoat 99113 Chain lubricant OKS 451 13 2 Lubricant for food industry S...

Страница 16: ...datory that all steps for decommissioning the machine are carried out in the indicated sequence First secure the working area for decommissioning leaving plenty of space Read the chapter Safety instru...

Отзывы: