Expl.-group of dust 

IIIA 

IIIA 

Temperature class - gases 

Temperature class - dust 

T4 

T135°C 

T3 

T200°C 

 

 

   

DANGER!

 

The classification for the device can be found on the EX-type plate on the unit. 

The device must only be used in the classification stated or in a lower classification.

 

 

2.6.2 

Surface temperature of the devices 

 

   

DANGER!

 

The temperature class mentioned on the EX-type plate on the unit must be observed, - make sure 
that the max. surface temperature is even fallen short of. 

 

 

   

DANGER!

 

The maximum surface temperature of the equipment must always be lower than the ignition 
temperature of the gas/vapour/dust/air mixture. Equipment which has been classified in higher 
temperature classes is, of course, also approved for use in applications with lower temperature 
classes. As gas/air mixtures for T5 do not occur with normal use, and only very rarely occur for T6, 
for specific gas/air mixtures such as carbon disulphide (IIC), our hoists are not rated for these 
temperature classes and must not be used for these classes.

 

 

 

Temperature 

class 

Ignition tem-

perature of gas 

°C 

max. surface 

temperature of the 

operating material in 

°C 

T1 

>450 

450 

T2 

>300  <450 

300 

T3 

>200  <300 

200 

T4 

>135  <200 

135 

T5

 

>100  <135

 

100 

T6

 

>85    <100

 

85 

 

2.6.3 

EX zone classification 

Areas that are prone to explosion are classified into zones. The owner must determine the zone that exists. 
Information on the zone classification can be found in IEC 60079-10 and in national standards. The following 
table contains an overview of the zone classification in combination with the device category. 

 

Gases 

Vapours 

Mist 

device category 

(Gases) 

Dust 

device category 

(dust) 

explosive 

atmosphere 

is present 

Zone 0 

1G 

Zone 20 

1D 

continuously, long-term or 

frequently 

Zone 1 

2G 

Zone 21 

2D 

occasionally 

Zone 2 

3G 

Zone 22 

3D 

rarely or short-term 

 

 

Содержание 32/20EX

Страница 1: ...2D Ex h IIIA T135 C Db II 2G Ex h IIB T3 Gb or II 2D Ex h IIIA T200 C Db DANGER Not to be used with IIC gases and IIB gases hydrogen sulphide and ethylene oxide and light metal and shock sensitive du...

Страница 2: ...Information 3 2 Safety 3 2 1 Warning notice and symbols 3 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 5 2 5 Basic safety measures 5 2 6 Explosio...

Страница 3: ...damage immediately to the forwarding agent This manual serves for safe and efficient use of this hoist Illustrations serve to explain something and may differ from the illustration of the existing un...

Страница 4: ...uipment i e regarding organization of work work flow and human resources In particular the owner user must ensure that The unit is only used appropriately The device is only operated in a fault free f...

Страница 5: ...21 Devices of this category have been specially modified and labeled by the manufacturer DANGER The permissible ambient temperature must not be exceeded Moving horizontally on beams DANGER The use is...

Страница 6: ...ide and light metal and shock sensitive dusts No use in temperature class T5 or T6 It is not allowed to use the equipment in area at risk from explosion where gas AND dust does both exist at the same...

Страница 7: ...ding e g c construction safety k encapsulation of liquids IIB explosion group II gases IIA IIB IIC limit gap widths MESG 0 9 mm limit gap widths MESG 0 9 to 0 5 mm limit gap widths MESG 0 5 mm T4 Temp...

Страница 8: ...ixtures for T5 do not occur with normal use and only very rarely occur for T6 for specific gas air mixtures such as carbon disulphide IIC our hoists are not rated for these temperature classes and mus...

Страница 9: ...5 52 693 01 01 00 9 2 6 4 Explosion hazards recognizing and preventing 3 Transport and Storage...

Страница 10: ...GER Units that show corrosion must be taken out of service 4 Description 4 1 Areas of application The devices must be as far as possible installed in a covered room If they are used in the open protec...

Страница 11: ...all standard beams with inclined and parallel flanges Side plates Made of steel plate with integrated wheel fracture supports load bars Device with 2 load bolts Different bolt lengths are available f...

Страница 12: ...e inner side X increases or from the inner to the outer side X decreases Washers 6 and rubber discs depended on type leave a distance for the load hook It is important that the load hangs in the middl...

Страница 13: ...mm 1 1 5 mm each side bigger and for trolleys from 4 t up 3 5 mm 1 5 2 5 mm each side bigger than the flange width B of the beam 6 4 Tools 7 Control Only people that are familiar with the operation o...

Страница 14: ...regard to design and kind of use The license will be given to qualified person be the approved supervision authorities Z S 9 Safety check Before putting into service initially or when putting back in...

Страница 15: ...BER Renolit FEP 2 Alvania EP 2 Unirex EP 2 Mobilux EP 2 MULTIS EP2 Stabylan 5006 Optimol Viscoleb 1500 Kl beroil 4UH 1 1500 Wolfracoat 99113 Chain lubricant OKS 451 13 2 Lubricant for food industry S...

Страница 16: ...datory that all steps for decommissioning the machine are carried out in the indicated sequence First secure the working area for decommissioning leaving plenty of space Read the chapter Safety instru...

Отзывы: