5.52.653.00.01.06
13
13
Inspection
13.1
Periodic checks
Independently from the regulations of the individual countries, lifting devices must be checked at least yearly
by a qualified person or licensed qualified person regarding its functional safety.
at
commissioning
daily
checks
1st maintenance
after
3 months
Inspection
Maintenance
every
3 months
Inspection
Maintenance
every
12 months
check screw connections
X
X
check the bearings
X
check the trolley wheels
X
check lubrication of the driving pinion
X
X
buffers - check correct position and wear
X
X
electric motor* - check the brake lining
X
electric motor* - check the brake
X
X
pneumatic motor*
X
X
X
Have the equipment checked by an expert
(periodic inspection)
X
*as far as applicable
14
Service
14.1
Electric motor
For the motor it is sufficient to keep the cooling airways clean and monitor the roller bearing and its
lubrication status.
A high temperature fat must be used if the roller bearing is replaced.
CAUTION!
Brake linings and surfaces must always be clean and fat-free. Even very small amounts of dirt can reduce
the braking moment considerably.
15
Trouble
Please pay attention to the following in case of problems:
Troubles with the equipment must only be repaired by qualified personnel.
Secure the unit against unintended operation start.
Put up a warning note indicating that the unit is not to be used.
Secure the working area of moving parts of the unit.
Please read the chapter "Safety instructions".
Notes on the repair of faults are found in the following table.
For the repair of failures please contact our service department.
CAUTION!
Trouble caused by wear or damage to parts such as wire ropes, chains, chain wheels, axes, bearings,